A Low-Cost Instrumented Shoe System for Gait Phase Detection Based on Foot Plantar Pressure Data
Open Access
- 26 September 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 12, 84-96
Abstract
This paper presents a novel low-cost and fully-portable instrumented shoe system for gait phase detection. The instrumented shoe consists of 174 independent sensing units constructed based on an off-the-shelf force-sensitive film known as the Velostat conductive copolymer. A zero potential method was implemented to address the crosstalk effect among the matrix-formed sensing arrays. A customized algorithm for gait event and phase detection was developed to estimate stance sub-phases including initial contact, flat foot, and push off. Experiments were carried out to evaluate the performance of the proposed instrumented shoe system in gait phase detection for both straight-line walking and turning walking. The results showed that the mean absolute time differences between the estimated phases by the proposed instrumented shoe system and the reference measurement ranged from 45 to 58 ms during straight-line walking and from 51 to 77 ms during turning walking, which were comparable to the state of art.Clinical and Translational Impact Statement—By allowing convenient gait monitoring in home healthcare settings, the proposed system enables extensive ADL data collection and facilitates developing effective treatment and rehabilitation strategies for patients with movement disorders.Keywords
Funding Information
- National Natural Science Foundation of China (11702175, 32171306)
- Shenzhen Science and Technology Program (JCYJ20210324093005015)
- Open Project Program of Key Laboratory for Sport Shoes Upper Materials of Fujian Province, Fujian Huafeng New Material Company Ltd (SSUM21X)
- Major Projects for Industry-University Research Collaborative Innovation of Science and Technology Plan of Guangzhou (201604020095)
This publication has 51 references indexed in Scilit:
- Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensorsGait & Posture, 2013
- Foot Plantar Pressure Measurement System: A ReviewSensors, 2012
- Measurement errors in the scanning of resistive sensor arraysSensors and Actuators A: Physical, 2010
- Plantar pressure measurements using an in-shoe system and a pressure platform: A comparisonGait & Posture, 2010
- A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive forceJournal of Biomechanics, 2008
- A three-dimensional biomechanical comparison between turning strategies during the stance phase of walkingHuman Movement Science, 2005
- A reliable gait phase detection systemIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- Real-time gait event detection for paraplegic FES walkingIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- Dynamic contact stress analysis using a compliant sensor arrayMeasurement, 1993
- In-shoe plantar pressure measurement: a reviewThe Foot, 1992