Junpeng Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junpeng Tang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Chao Chen
Department of Orthopedics, School of Traditional Chinese Medicine, Southern Medical University, Guangdong, Guangzhou, China
1 shared publicationGengshu Chen
Institute of Human Factors and Ergonomics, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen, China
1 shared publicationQingsong Duan
Institute of Human Factors and Ergonomics, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen, China
1 shared publication- Xingda Qu
Institute of Human Factors and Ergonomics, Shenzhen University
1 shared publication - Xinyao Hu
Institute of Human Factors and Ergonomics, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen, China
1 shared publication - Zhenglong Sun
School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 12, 84-96
A Low-Cost Instrumented Shoe System for Gait Phase Detection Based on Foot Plantar Pressure Data
This paper presents a novel low-cost and fully-portable instrumented shoe system for gait phase detection. The instrumented shoe consists of 174 independent sensing units constructed based on an off-the-shelf force-sensitive film known as the Velostat conductive copolymer. A zero potential method was implemented to address the crosstalk effect among the matrix-formed sensing arrays. A customized algorithm for gait event and phase detection was developed to estimate stance sub-phases including initial contact, flat foot, and push off. Experiments were carried out to evaluate the performance of the proposed instrumented shoe system in gait phase detection for both straight-line walking and turning walking. The results showed that the mean absolute time differences between the estimated phases by the proposed instrumented shoe system and the reference measurement ranged from 45 to 58 ms during straight-line walking and from 51 to 77 ms during turning walking, which were comparable to the state of art.Clinical and Translational Impact Statement—By allowing convenient gait monitoring in home healthcare settings, the proposed system enables extensive ADL data collection and facilitates developing effective treatment and rehabilitation strategies for patients with movement disorders.
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 12, 84-96
Open AccessA Low-Cost Instrumented Shoe System for Gait Phase Detection Based on Foot Plantar Pressure Data
This paper presents a novel low-cost and fully-portable instrumented shoe system for gait phase detection. The instrumented shoe consists of 174 independent sensing units constructed based on an off-the-shelf force-sensitive film known as the Velostat conductive copolymer. A zero potential method was implemented to address the crosstalk effect among the matrix-formed sensing arrays. A customized algorithm for gait event and phase detection was developed to estimate stance sub-phases including initial contact, flat foot, and push off. Experiments were carried out to evaluate the performance of the proposed instrumented shoe system in gait phase detection for both straight-line walking and turning walking. The results showed that the mean absolute time differences between the estimated phases by the proposed instrumented shoe system and the reference measurement ranged from 45 to 58 ms during straight-line walking and from 51 to 77 ms during turning walking, which were comparable to the state of art.Clinical and Translational Impact Statement—By allowing convenient gait monitoring in home healthcare settings, the proposed system enables extensive ADL data collection and facilitates developing effective treatment and rehabilitation strategies for patients with movement disorders.