Novel Bragg peak characterization method using proton flux measurements on plastic scintillators
- 11 November 2024
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (22) , 225005
Abstract
Objective. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient. Approach. In this paper a protocol to reconstruct a Pristine Bragg Peak exploring the direct correlation between the particle flux and the dose deposited by particles is presented. Proton flux measurements at the HollandPTC and FLUKA Monte Carlo simulations are used for this purpose. This new protocol is applicable to plastic scintillator detectors developed for Quality Assurance applications. In order to obtain the Bragg curve using a plastic fiber detector, a PMMA phantom with a decoupled and moveable stepper was designed. The step phantom allows to change the depth of material in front of the fiber detector during irradiations. The Pristine Bragg Peak reconstruction protocol uses the measured flux of particles at each position and multiplies it by the average dose obtained from the Monte Carlo simulation at each position. Main results. The results show that with this protocol it is possible to reconstruct the Bragg Peak with an accuracy of about 470 µm, which is in accordance with the tolerances set by the AAPM. Significance. It has the advantage to be able to overcome the quenching problem of scintillators in the high ionization density region of the Bragg peak.Keywords
Funding Information
- Laboratório de Instrumentação e Física Experimental de Partículas (UIDP/50007/2020)
- Fundação para a Ciência e a Tecnologia (CERN/FIS-TEC/0017/2021)
This publication has 28 references indexed in Scilit:
- A Geant4 based simulation platform of the HollandPTC R&D proton beamline for radiobiological studiesPhysica Medica, 2023
- Technical note: Measurement of the bunch structure of a clinical proton beam using a SiPM coupled to a plastic scintillator with an optical fiberMedical Physics, 2023
- A review of proton therapy – Current status and future directionsPrecision Radiation Oncology, 2022
- Proton therapy needs further technological development to fulfill the promise of becoming a superior treatment modality (compared to photon therapy)Journal of Applied Clinical Medical Physics, 2021
- A scoping review of patient selection methods for proton therapyJournal of Medical Radiation Sciences, 2021
- Technical Note: Characterization of the new microSilicon diode detectorMedical Physics, 2019
- AAPM task group 224: Comprehensive proton therapy machine quality assuranceMedical Physics, 2019
- Overview of the FLUKA codeAnnals of Nuclear Energy, 2015
- Quality assurance in protontherapy: a systematic approach in progress at OrsayBulletin du Cancer/Radiothérapie, 1996
- Time response of plastic scintillatorsNuclear Instruments and Methods, 1974