Latest Publications

  • Open Access

    Influence of Precursor Purity on the low-dose TL and OSL Response of Flux-grown Pure α-Al2O3

    by Cristiana Rodrigues, João Gentil Mendes Saraiva, Luís Cerqueira Alves, Ana Luísa Rodrigues, António Pereira Gonçalves, Luís Peralta

    Luminescence dosimetry continues to advance through efforts to improve detector sensitivity, stability, and cost‑effectiveness. Within this scope, Al2O3 crystals were produced by the flux‑growth method, a low‑cost crystal growth technique, using MoO3 precursors with purities from 99.0% to 99.95%, and Al2O3 of 99.99% and 99.999% purity. Elemental characterization was pursued using µ-PIXE and PIGE. The thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristic response to 90Sr/90Y β-radiation over the dose range of 30 mGy to 15 Gy was investigated, with emphasis on the role of precursor purity, using the Risø-DA20 reader. Variations in MoO3 purity resulted in differences in trap distribution, reflected in both TL and OSL behavior. All samples showed supralinear TL and OSL dose‑response without saturation within the studied range and demonstrated high signal reproducibility (< 5%). Increasing MoO3 purity led to substantial improvements in TL/OSL intensity and low‑dose sensitivity, with 99.95% purity providing the best performance-cost balance. The results confirm that precursor purity is a critical parameter controlling luminescence efficiency in flux‑grown sapphire. Overall, the flux‑growth method emerges as a promising and economically attractive route for producing Al2O3 dosimetric materials, including for low‑dose applications, using the appropriate starting materials. Further optimization of growth conditions or targeted doping strategies may enable additional improvements in detector sensitivity and performance.

  • Open Access

    Influence of Precursor Purity on the low-dose TL and OSL Response of Flux-grown Pure α-Al2O3

    by Cristiana Rodrigues, João Gentil Mendes Saraiva, Luís Cerqueira Alves, Ana Luísa Rodrigues, António Pereira Gonçalves, Luís Peralta

    Luminescence dosimetry continues to advance through efforts to improve detector sensitivity, stability, and cost‑effectiveness. Within this scope, Al2O3 crystals were produced by the flux‑growth method, a low‑cost crystal growth technique, using MoO3 precursors with purities from 99.0% to 99.95%, and Al2O3 of 99.99% and 99.999% purity. Elemental characterization was pursued using µ-PIXE and PIGE. The thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristic response to 90Sr/90Y β-radiation over the dose range of 30 mGy to 15 Gy was investigated, with emphasis on the role of precursor purity, using the Risø-DA20 reader. Variations in MoO3 purity resulted in differences in trap distribution, reflected in both TL and OSL behavior. All samples showed supralinear TL and OSL dose‑response without saturation within the studied range and demonstrated high signal reproducibility (< 5%). Increasing MoO3 purity led to substantial improvements in TL/OSL intensity and low‑dose sensitivity, with 99.95% purity providing the best performance-cost balance. The results confirm that precursor purity is a critical parameter controlling luminescence efficiency in flux‑grown sapphire. Overall, the flux‑growth method emerges as a promising and economically attractive route for producing Al2O3 dosimetric materials, including for low‑dose applications, using the appropriate starting materials. Further optimization of growth conditions or targeted doping strategies may enable additional improvements in detector sensitivity and performance.

  • Open Access

    Thickness and Uniformity of Commercial Aluminum Foils

    by L. Peralta, A. I. Campos, M. S. Rodrigues

    There are several brands of aluminum foils for domestic use on the market. The vast majority do not provide consumers with any type of information about the characteristics of the film, in particular its thickness. In this work, we compare the thickness and non-uniformity thickness of aluminum foil on sale in the Portuguese market. The method used was the loss of energy of alpha particles as they passed through the foil. For all tested brands, the thickness value is approximately 11 µm. Regarding the non-uniformity thickness, we conclude that the standard deviation is of the order of 5% of the foil average thickness.


  • Novel Bragg peak characterization method using proton flux measurements on plastic scintillators

    by D R Guerreiro, J G Saraiva, L Peralta, C Rodrigues, M Rovituso, E van der Wal, Dennis R Schaart, P Crespo, H Simões, J M Sampaio

    Objective. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient. Approach. In this paper a protocol to reconstruct a Pristine Bragg Peak exploring the direct correlation between the particle flux and the dose deposited by particles is presented. Proton flux measurements at the HollandPTC and FLUKA Monte Carlo simulations are used for this purpose. This new protocol is applicable to plastic scintillator detectors developed for Quality Assurance applications. In order to obtain the Bragg curve using a plastic fiber detector, a PMMA phantom with a decoupled and moveable stepper was designed. The step phantom allows to change the depth of material in front of the fiber detector during irradiations. The Pristine Bragg Peak reconstruction protocol uses the measured flux of particles at each position and multiplies it by the average dose obtained from the Monte Carlo simulation at each position. Main results. The results show that with this protocol it is possible to reconstruct the Bragg Peak with an accuracy of about 470 µm, which is in accordance with the tolerances set by the AAPM. Significance. It has the advantage to be able to overcome the quenching problem of scintillators in the high ionization density region of the Bragg peak.


  • Development of a plastic scintillating optical fibers array dosimeter for radiobiology

    by D.R. Guerreiro, J.G. Saraiva, M.J. Borges, J.M. Sampaio, L. Peralta

    In this work a detector prototype built as an array of Scintillating Plastic Optical fibers (SPOFs) is presented. The primary aim of this detector is to improve spatial resolution, provide real-time dose mapping and a tissue equivalent detector in radiobiology experiments. Details on the design and construction are provided along with the initial tests carried out using low-energy X-ray and electrons from a 90Sr source. Regarding the design and construction of the detector, the mechanical design of the irradiation box is presented and the Quality Assurance (QA) the optical fiber arrays were subjected to is discussed. The QA measurements show that the alignment of the optical fibers is within acceptable tolerances for dose readout. After the detector assembly, correction factors for each fiber were extracted from tests using a collimated X-ray beam. Special care was taken to ensure that each fiber is submitted to the same dose. Broad field tests show that the measurements are reproducible to within 3 %. Potential innovative features of this system for radiobiological experiments are discussed as well as the future follow-up of the prototype.


  • Open Access

    Field output correction factors of small static field for IBA razor nanochamber

    by Dalila Alexandra Rodrigues Mateus, Carlo Greco, Luis Peralta

    Purpose. The goal of this work is present results of field output factors (OF) using an IBA CC003 (Razor NanoChamber) and compare these results with PTW 60019 (MicroDiamond) and IBA Razor Diode. The experimental results for IBA CC003 were also compared with Monte Carlo (MC) Simulation, using Penelope and Ulysses programs. In addition, field output correction factors ( k Q clin , Q msr f clin , f msr ) for IBA CC003 were derived with three different methods: (1) using PTW 60019 and IBA Razor as reference detectors; (2) comparison between MC and experimental measurements; and (3) using only MC.Material and Methods. The beam collimation included in this study were (1) square field size between 10 × 10 and 0.5 × 0.5 cm2 defined by the MLC and jaws and (2) cones of different diameters. For IBA CC003 it was determined the polarity and ion collection efficiency correction factors in parallel and perpendicular orientation.Results. The results indicate (1) the variation of polarity effect with the field size is relevant for the determination of OF using IBA CC003, especially for parallel orientation; (2) there is no significant variation of the ion collection efficiency with the field size using IBA CC003 in parallel orientation; (3) OF differences between IBA CC003 and PTW 60019/IBA Razor, and experimental and MC results, increase with decreasing field size;The k Q clin , Q msr f clin , f msr results indicate (1) using the first and second method, k Q clin , Q msr f clin , f msr increase with decreasing field size, which can be related with the influence of the volume effect and (2) using the third method, k Q clin , Q msr f clin , f msr decrease with decreasing field size, which can be explained by the perturbation effect.Conclusions. Our results demonstrate the need of applying k Q clin , Q msr f clin , f msr for IBA CC003 for S clin ≤ 1 cm, to compensate for volume averaging and perturbations effects.


  • Radioactivity in a bucket

    by Luis Peralta

    In radiation physics classes, point sources are typically used, for which it is relatively easy to describe the signal obtained by a radiation detector, such as the NaI(Tl) scintillation detector. The use of large extended radiation sources is generally avoided due to the mathematical complexity that their description may involve. However, the use of Monte Carlo simulation methods allows this limitation to be overcome. Potassium chloride, containing the 40K isotope, is an ideal candidate for carrying out this type of experiment. The source activity is obtained through the detection of the 1460.8 keV gamma-photon emitted in the 40K decay. In the first experiment, a cylindrical container is used, placing the NaI(Tl) detector in its center and filling the remaining space with potassium chloride. In a second, more complex case, a large radioactive source consisting of a container filled with a mixture of sand and potassium chloride, with the NaI(Tl) detector placed in the center of the mixture, is used. In this case, the mass of potassium chloride is approximately 1/5 of the sand mass. In both experiments, the detection efficiency is obtained by Monte Carlo simulation. A careful analysis of the experimental data allows to obtain a good agreement between the measured and calculated value of the activity.


  • Open Access

    Radioactivity in a bucket

    by Luis Peralta

    In Radiation Physics classes, point sources are typically used, for which it is relatively easy to describe the signal obtained by a radiation detector, such as the NaI(Tl) scintillation detector. The use of large extended radiation sources is generally avoided due to the mathematical complexity that their description may involve. However, the use of Monte Carlo simulation methods allows this limitation to be overcome. Potassium chloride, containing the 40K isotope, is an ideal candidate for carrying out this type of experiment. The source activity is obtained through the detection of the 1460.8 keV gamma-photon emitted in the 40K decay. In the first experiment, a cylindrical container is used, placing the NaI(Tl) detector in its center and filling the remaining space with potassium chloride. In a second, more complex case, a large radioactive source consisting of a container filled with a mixture of sand and potassium chloride, with the NaI(Tl) detector placed in the center of the mixture, is used. In this case, the mass of potassium chloride is approximately 1/5 of the sand mass. In both experiments, the detection efficiency is obtained by Monte Carlo simulation. A careful analysis of the experimental data allows to obtain a good agreement between the measured and calculated value of the activity.