Sensitivity of Intervertebral Disc Finite Element Models to Internal Geometric and Non-geometric Parameters
Open Access
- 17 June 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Abstract
Finite element models are useful for investigating internal intervertebral disc (IVD) behaviours without using disruptive experimental techniques. Simplified geometries are commonly used to reduce computational time or because internal geometries cannot be acquired from CT scans. This study aimed to (1) investigate the effect of altered geometries both at endplates and the nucleus-anulus boundary on model response, and (2) to investigate model sensitivity to material and geometric inputs, and different modelling approaches (graduated or consistent fibre bundle angles and glued or cohesive inter-lamellar contact). Six models were developed from 9.4 T MRIs of bovine IVDs. Models had two variations of endplate geometry (a simple curved profile from the centre of the disc to the periphery, and precise geometry segmented from MRIs), and three variations of NP-AF boundary (linear, curved, and segmented). Models were subjected to axial compressive loading (to 0.86 mm at a strain rate of 0.1/s) and the effect on stiffness and strain distributions, and the sensitivity to modelling approaches was investigated. The model with the most complex geometry (segmented endplates, curved NP-AF boundary) was 3.1 times stiffer than the model with the simplest geometry (curved endplates, linear NP-AF boundary), although this difference may be exaggerated since segmenting the endplates in the complex geometry models resulted in a shorter average disc height. Peak strains were close to the endplates at locations of high curvature in the segmented endplate models which were not captured in the curved endplate models. Differences were also seen in sensitivity to material properties, graduated fibre angles, cohesive rather than glued inter-lamellar contact, and NP:AF ratios. These results show that FE modellers must take care to ensure geometries are realistic so that load is distributed and passes through IVDs accurately.Keywords
This publication has 60 references indexed in Scilit:
- Geometry strongly influences the response of numerical models of the lumbar spine—A probabilistic finite element analysisJournal of Biomechanics, 2012
- Parametric convergence sensitivity and validation of a finite element model of the human lumbar spineComputer Methods in Biomechanics and Biomedical Engineering, 2011
- Human intervertebral disc internal strain in compression: The effect of disc region, loading position, and degenerationJournal of Orthopaedic Research, 2010
- Effect of multilevel lumbar disc arthroplasty on spine kinematics and facet joint loads in flexion and extension: a finite element analysisEuropean Spine Journal, 2010
- Theoretical and Uniaxial Experimental Evaluation of Human Annulus Fibrosus DegenerationJournal of Biomechanical Engineering, 2009
- Measurement of local strains in intervertebral disc anulus fibrosus tissue under dynamic shear: Contributions of matrix fiber orientation and elastin contentJournal of Biomechanics, 2009
- Frequency-Dependent Behavior of the Intervertebral Disc in Response to Each of Six Degree of Freedom Dynamic LoadingSpine, 2008
- Shear mechanical properties of human lumbar annulus fibrosusJournal of Orthopaedic Research, 1999
- Nonlinear Analysis of Intervertebral Disk Under Dynamic LoadJournal of Biomechanical Engineering, 1990
- Investigation of the Laminate Structure of Lumbar Disc Anulus FibrosusSpine, 1990