Abstract
Purpose: To describe the long-term observations of the first human implantation of EndoArt, a synthetic endothelial implant, in a small cohort of patients with corneal edema secondary to endothelial dysfunction. Methods: This retrospective case series analyzed 5 eyes from 5 patients who underwent EndoArt implantation, with a minimum follow-up of 12 months. Clinical outcomes, including corrected distance visual acuity and central corneal thickness, were evaluated pre- and postoperatively. Rebubbling procedures and any complications were recorded. Histological analysis was performed on 1 explanted corneal button. Results: The mean follow-up was 38.4 ± 20 months (range: 19–72 months). A reduction in mean central corneal thickness was observed, from 741.2 ± 88.3 μm preoperatively to 558.4 ± 72.7 μm postoperatively (P < 0.001). Corrected distance visual acuity improved in 4 of 5 eyes, although not significantly overall (P = 0.19). The mean number of rebubbling procedures was 2.8 ± 1.3 per eye. No serious implant-related complications were observed during the follow-up period. Histological findings showed fibrocellular tissue partially integrating the implant, which may contribute to graft adherence. Two patients with Fuchs dystrophy received the device as a primary procedure because of ethical or religious constraints regarding donor tissue. Conclusions: This small pilot series of the first human EndoArt implantation observed a significant reduction of corneal edema over time and a favorable safety profile in select patients. Although these findings are encouraging, they should be interpreted with caution given the limited sample size. Larger, controlled studies are needed to better understand the safety, efficacy, and long-term outcomes of this synthetic implant.Keywords
This publication has 43 references indexed in Scilit:
- EndoArt®: Ergebnisse bei Patienten mit Glaukom-Drainage-ImplantatenDie Ophthalmologie, 2024
- Pull-through insertion of EndoArt for complex eyesAmerican Journal of Ophthalmology Case Reports, 2023
- Clinicopathologic Correlations of Retrocorneal Membranes Associated With Endothelial Corneal Graft FailureAmerican Journal of Ophthalmology, 2020
- Predicting the Prognosis of Fuchs Endothelial Corneal Dystrophy by Using Scheimpflug TomographyOphthalmology, 2020
- Immune reactions after modern lamellar (DALK, DSAEK, DMEK) versus conventional penetrating corneal transplantationProgress in Retinal and Eye Research, 2019
- Global Survey of Corneal Transplantation and Eye BankingJAMA Ophthalmology, 2016
- The corneal fibrosis response to epithelial–stromal injuryExperimental Eye Research, 2016
- Descemet Membrane Endothelial Keratoplasty for Graft Failure After Descemet Stripping Endothelial KeratoplastyJAMA Ophthalmology, 2015
- Retrocorneal Membranes: A Comparative Immunohistochemical Analysis of Keratocytic, Endothelial, and Epithelial OriginsAmerican Journal of Ophthalmology, 2010
- Retrocorneal Fibrous Membranes in Failed Corneal GraftsAmerican Journal of Ophthalmology, 1993