MFMaximilian Friedrich

Maximilian Friedrich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maximilian Friedrich has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Victor Aristide Augustin

    Department of Ophthalmology, David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), University of Heidelberg, Heidelberg, Germany

    8 shared publications
  • Gerd Uwe Auffarth

    International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany

    7 shared publications
  • Hyeck-Soo Son

    The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany

    7 shared publications
  • Ramin Khoramnia

    Department of Ophthalmology, Faculty of Medicine, University Hospital Carl Gustav Carus, TU Dresden, Dresden, Germany

    5 shared publications
  • Gerd Uwe Auffarth

    Department of Ophthalmology, University of Heidelberg, David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Heidelberg, Germany

    3 shared publications
  • Hyeck-Soo Son

    David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany

    3 shared publications

Latest Publications

  • Combining small aperture approach and toric correction for irregular astigmatism management

    by Hyeck-Soo Son, Asu Rayamajhi, Ava Niknahad, Ramin Khoramnia, Gerd U. Auffarth, Victor A. Augustin, Maximilian Friedrich, Grzegorz Łabuz

    Purpose: To investigate the potential of a hybrid intraocular (IOL) design featuring both small-aperture and toric elements to address the limitations of irregular astigmatism in cataract surgery. IOLs featuring a small-aperture have shown promise in managing such cases through the “pinholde effect” yet they do not correct the underlying astigmatic power. Setting: David J. Apple Laboratory for Ocular Pathology, Heidelberg, Germany. Design: Experimental study. Methods: A retrospective analysis of 22 eyes with irregular astigmatism was conducted using semipersonalized eye models derived from Pentacam tomography data. Simulations were performed in OpticStudio to evaluate 3 IOL systems: a toric IOL, a small-aperture, and a combined small-aperture + toric IOL. Image quality was assessed using Strehl ratio (SR) and root mean square (RMS) error. Landolt C simulations and correlation analyses were also performed. Results: The hybrid IOL significantly outperformed the toric and small-aperture IOLs alone, achieving mean SR of 0.80 ± 0.17 (vs 0.10 ± 0.07 and 0.20 ± 0.19, respectively, P < .001) and the lowest RMS error (0.07 μm, P < .001). Simulations demonstrated superior visual quality and less sensitivity to corneal asymmetry. R 2 analyses confirmed a strong association between corneal astigmatism and improved optical quality in the combined model. Conclusions: Integrating a toric correction within a small-aperture optic yields superior optical performance in irregular astigmatism simulations. In clinical practice, combining sulcus-fixated pinhole implants with toric posterior-chamber IOLs or sulcus-fixated toric lenses with a small-aperture posterior-chamber IOL may achieve better outcomes in complex corneal profiles.

  • Open Access

    Repeatability of Epithelial Thickness Mapping in Normal and Keratoconus Eyes Using a Novel Hybrid Scheimpflug—Optical Coherence Tomography Device

    by Victor Aristide Augustin, Maximilian Friedrich, Julia Keim, Luisa Finken, Emilia Felter, Hyeck-Soo Son, Gerd Uwe Auffarth

    Purpose: A novel diagnostic device combining Scheimpflug and anterior segment optical coherence tomography promises increased accuracy in corneal diagnostics. The aim of this study was to analyze the epithelial thickness measurement repeatability in healthy and keratoconus eyes and define severity-dependent thresholds. Methods: This prospective, cross-sectional, observational, monocentric study included a total of 217 eyes of 217 subjects divided into a keratoconus group (166 eyes of 166 subjects) and a healthy control group (51 eyes of 51 subjects). Keratoconus diagnosis and stage was established using multimodal imaging. Three measurements were performed with the novel combined Scheimpflug and optical coherence tomography device (Pentacam Cornea optical coherence tomography) on the same day. Repeatability coefficients (RCs) with two-sided 95% confidence intervals (CIs) were calculated for epithelial parameters. The repeatability was compared between groups and according to keratoconus severity and crosslinking status. Results: The median repeatability of the epithelial thickness was slightly better in the healthy group (RC = 3.3) compared with the keratoconus group (RC = 3.9; P < 0.001) when the tear film was excluded. The overall median repeatability with (RC = 3.7) and without tear film (RC = 3.8) did not differ significantly ( P > 0.05). Repeatability worsened significantly in severe keratoconus stages ( P < 0.01), whereas crosslinking status had only a marginal effect. Conclusions: The hybrid tomographic device demonstrated high intrasubject repeatability for epithelial thickness assessment in healthy and keratoconus eyes, supporting its technical feasibility for clinical use. Further studies are needed to analyze the benefit of incorporating epithelium into established keratoconus scores using the hybrid system.


  • Open Access

    Visual Outcomes and Safety of Ray-Tracing-Guided Laser-Assisted In Situ Keratomileusis: A Systematic Review and Meta-Analysis

    by Maximilian Friedrich, Victor A. Augustin, Gerd U. Auffarth, Ramin Khoramnia, Hyeck-Soo Son

    Topic The aim of this analysis was to evaluate the visual outcome and safety profile after ray-tracing-guided laser-assisted in situ keratomileusis (RTG-LASIK) for myopia with or without astigmatism. Clinical relevance RTG-LASIK is a modern approach in refractive surgery using only objective and automated measurements aiming to improve visual outcomes. Methods In this systematic literature review and meta-analysis (International Prospective Register of Systematic Reviews [PROSPERO] ID: CRD420251179631), original peer-reviewed clinical studies on the visual outcomes of RTG-LASIK in eyes with myopia ± astigmatism were included. Exclusion criteria were corneal ectasia or other ocular comorbidities, hyperopia, and ablation profile modification by the surgeon. Cochrane, Embase, PubMed, and Web of Science databases were screened on 31 October 2025. The risk of bias was assessed using the Risk of Bias in Non-Randomized Studies-of Interventions tool. Primary effect measures were the proportions of eyes achieving 20/20 uncorrected distance visual acuity (UDVA) and losing ≥ 1 line of corrected distance visual acuity (CDVA) after RTG-LASIK. Secondary outcomes included the distribution of eyes regarding preoperative CDVA and postoperative UDVA, changes in Snellen lines for CDVA and UDVA relative to preoperative CDVA, postoperative manifest refraction spherical equivalent (MRSE), higher-order aberrations (HOAs), and other refractive parameters, synthesized using a random-effects model. In addition, postoperative complications were documented. Results In total, 14 clinical studies with a total of 1577 eyes were included in the meta-analysis. The pooled percentage of eyes with postoperative UDVA ≥ 20/20 was 99.17% (95% confidence interval [CI]: 95.75%, 99.84%; I2 = 47.4%; 14 studies; n = 1577). Loss of ≥ 1 line in CDVA after RTG-LASIK occurred in 2.21% (95% CI: 1.07%, 4.52%; I2 = 38.5%; 11 studies; n = 1384). CDVA showed an improvement in nearly half of all cases. In addition, postoperative UDVA tended to improve compared with preoperative CDVA. MRSE was within 0.5 D of target refraction in 95.21% but showed a slight trend toward overcorrection. Total HOAs increased slightly by 0.087 µm (95% CI: 0.027, 0.148; I2 = 97.5%; 8 studies; n = 1189), while spherical aberration and trefoil tended to decrease after RTG-LASIK. The studies reported nine refractive retreatments and a generally favorable complication profile. Discussion This meta-analysis suggests that RTG-LASIK may be a safe and effective procedure for improving UDVA and CDVA in selected myopic eyes in the short term, with relatively low reported complication rates. However, larger prospective studies with longer follow-up are needed to confirm these findings and better define long-term safety and efficacy. Trial Registration This systematic review and meta-analysis has been prospectively registered at PROSPERO (PROSPERO ID: CRD420251179631).


  • Open Access

    Long-Term Observations of the First Human Implantation of an Artificial Endothelial Layer for Endothelial Dysfunction: A Pilot Study

    by Hyeck-Soo Son, Victor A. Augustin, Charles G. Eberhart, Maximilian Friedrich, Emanuel Reitemeyer, Nikola Henningsen, Oliver Hassel, Louise Blöck, Gerd U. Auffarth

    Purpose: To describe the long-term observations of the first human implantation of EndoArt, a synthetic endothelial implant, in a small cohort of patients with corneal edema secondary to endothelial dysfunction. Methods: This retrospective case series analyzed 5 eyes from 5 patients who underwent EndoArt implantation, with a minimum follow-up of 12 months. Clinical outcomes, including corrected distance visual acuity and central corneal thickness, were evaluated pre- and postoperatively. Rebubbling procedures and any complications were recorded. Histological analysis was performed on 1 explanted corneal button. Results: The mean follow-up was 38.4 ± 20 months (range: 19–72 months). A reduction in mean central corneal thickness was observed, from 741.2 ± 88.3 μm preoperatively to 558.4 ± 72.7 μm postoperatively (P < 0.001). Corrected distance visual acuity improved in 4 of 5 eyes, although not significantly overall (P = 0.19). The mean number of rebubbling procedures was 2.8 ± 1.3 per eye. No serious implant-related complications were observed during the follow-up period. Histological findings showed fibrocellular tissue partially integrating the implant, which may contribute to graft adherence. Two patients with Fuchs dystrophy received the device as a primary procedure because of ethical or religious constraints regarding donor tissue. Conclusions: This small pilot series of the first human EndoArt implantation observed a significant reduction of corneal edema over time and a favorable safety profile in select patients. Although these findings are encouraging, they should be interpreted with caution given the limited sample size. Larger, controlled studies are needed to better understand the safety, efficacy, and long-term outcomes of this synthetic implant.


  • Open Access

    Immediate sequential corneal allogeneic intrastromal ring segment transplantation and cataract surgery

    by Gerd U. Auffarth, Victor A. Augustin, Aylin Kilic, Ramin Khoramnia, Maximilian Friedrich, Hyeck-Soo Son


  • Open Access

    Visual and ultrastructural analysis after splitting of recipient’s Descemet membrane during Descemet membrane endothelial keratoplasty

    by Maximilian Friedrich, Jasper Lind, Hyeck-Soo Son, Timur Mert Yildirim, Gerd Uwe Auffarth, Victor Aristide Augustin

    Background: During Descemetorhexis in Descemet Membrane Endothelial Keratoplasty (DMEK), inadvertent lamellar splitting of the recipient’s Descemet membrane (DM) may occur, leaving DM remnants on the posterior corneal surface. This study investigates the influence of lamellar splitting on surgical outcome as well as the histological ultrastructure of split DMs. Methods: In this prospective, observational, single-centre cohort study 129 eyes of 102 patients were divided into two groups depending on the occurrence of intraoperative splitting. If splitting of the recipient’s DM occurred, the remnants were polished via irrigation/aspiration. The primary outcome was the corrected distance visual acuity (CDVA) four months after DMEK. Secondary outcomes were central corneal thickness (CCT), thinnest corneal thickness (TCT), posterior corneal density (PCD), endothelial cell loss (ECL), and the re-bubbling rate. For histopathological analysis two removed DMs were examined using scanning and transmission electron microscopy. Results: Intraoperative splitting occurred in 36 eyes (27.9%). The postoperative CDVA in the group with splitting (0.12 ± 0.12 logMAR) did not significantly differ from the group without splitting (0.12 ± 0.12 logMAR; p = 0.96). CCT, TCT, PCD, ECL, and the re-bubbling rate also did not significantly differ between both groups (p > 0.05). In ultrastructural analysis, the split layer had a thickness of 2 µm and showed an irregular splitting interface. Conclusion: Inadvertent lamellar splitting of the recipient’s DM during DMEK does not have a significant impact on the visual outcome. Therefore, polishing the DM remnants intraoperatively may address this complication in sufficient manner for optimizing visual outcomes.


  • Open Access

    Visual and Topographic Outcomes After Corneal Allogeneic Intrastromal Ring Segments for Keratoconus: A Systematic Review and Meta-Analysis

    by Maximilian Friedrich, Gerd Uwe Auffarth, Uri Soiberman, Victor Aristide Augustin, Ramin Khoramnia, Hyeck-Soo Son


  • Open Access

    Bubble-graft coverage after Descemet Membrane Endothelial Keratoplasty depending on gaze angle

    by Maximilian Friedrich, Hyeck-Soo Son, Rebecca Charlotte Buhl, Christine Maria Meyer, Timur Mert Yildirim, Ramin Khoramnia, Gerd Uwe Auffarth, Victor Aristide Augustin

    Purpose: In Descemet Membrane Endothelial Keratoplasty (DMEK) a gas bubble is usually used to attach the graft to the host cornea. In this study, we observed the bubble size and bubble-graft coverage at different gaze angles following DMEK. Methods: This observational prospective study analyzed 465 images of patients who underwent an uneventful DMEK. Intraoperatively, the anterior chamber was filled up to 90% of its volume with a 20% Sulfur Hexafluoride (SF6) gas-air mixture. Postoperatively, the bubble was photographed daily in different gaze angles ranging from a supine position (0°) to an upright position (90°) and a slightly inclined position (105°). The primary outcomes were bubble-graft coverage and bubble diameters depending on the gaze angle and time after DMEK. Results: The highest bubble-graft coverage was achieved at a 0° gaze angle at all times of measurement. In the first 48 h after DMEK, the mean bubble-graft coverage was over 85% at a gaze angle between 0° and 45°. Starting 72 h after DMEK, the graft coverage declined at all gaze angles. The graft coverage at a 0° gaze angle was 88.61 ± 10.90% after 96 postoperative hours, while the graft coverage was below 85% at all other gaze angles. Conclusion: Our clinical results provide novel insight into variation in bubble-graft coverage as a function of gaze angle and may be used to aid in patient counselling for appropriate body positioning following DMEK to prevent early graft detachment. Maintaining supine positioning seems to be most advantageous starting 48 h after DMEK.


  • Reply

    by Maximilian Friedrich, Christina Antonia Hofmann, Lizaveta Chychko, Hyeck-Soo Son, Ramin Khoramnia, Gerd Uwe Auffarth, Victor Aristide Augustin

  • Influence of Subclinical Corneal Edema on Contrast Sensitivity in Fuchs Endothelial Corneal Dystrophy

    by Maximilian Friedrich, Christina Antonia Hofmann, Lizaveta Chychko, Hyeck-Soo Md Son, Ramin Md Khoramnia, Gerd Uwe MD Auffarth, Victor Aristide Md Augustin

    Purpose: The aim of this study was to compare visual function, with a focus on contrast sensitivity, between patients with Fuchs endothelial corneal dystrophy (FECD) with and without subclinical corneal edema. Methods: In this cross-sectional, observational, single-center study, 46 pseudophakic eyes of 31 patients with FECD were divided into 2 groups depending on the presence of subclinical corneal edema. All eyes presented with a Krachmer grade of 5 and no clinical corneal edema. The criteria for subclinical corneal edema were loss of regular isopachs, displacement of the thinnest point, and focal posterior surface depression in Scheimpflug tomography. If more than 1 criterion was present, subclinical corneal edema was diagnosed. The corrected distance visual acuity, contrast sensitivity (Pelli–Robson chart and CSV-1000 test with optional glare), and straylight were measured. The differences between both groups were analyzed using clustered Wilcoxon rank-sum tests. Results: The corrected distance visual acuity and the contrast sensitivity, measured with a Pelli–Robson chart, were significantly inferior in eyes with subclinical corneal edema compared with eyes without subclinical edema (P < 0.05). At all spatial frequencies, eyes with subclinical edema demonstrated lower contrast sensitivity with a statistically significantly reduction in total contrast sensitivity when tested with (P = 0.005) and without (P = 0.002) glare. The straylight did not significantly differ between both groups (P > 0.05). Conclusions: The corrected distance visual acuity and contrast sensitivity were significantly reduced in FECD eyes with subclinical corneal edema compared with those with no subclinical edema. This decrease in visual quality may be considered when evaluating the need for surgical intervention at earlier stages of FECD.