Indexing and Designing Deadbands for Industrial Alarm Signals
- 13 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 8093-8103
Abstract
Alarm systems play critically important roles for the safe and efficient operation of industrial plants, but they often suffer from too many nuisance alarms. Deadbands are widely used in industrial alarm systems to reduce the number of nuisance alarms. This paper formulates an index to determine whether deadbands are suitable for removing nuisance alarms of an analog signal, and proposes a method to design the deadband width. First, the deadband index is defined from two metrics, namely, normalized alarm durations and normalized alarm deviations. If the index is larger than $45^{\circ}$ , as indicated by a hypothesis test, then nuisance alarms are associated with large/small normalized alarm durations/deviations, so that deadbands are suitable. Second, a design method is proposed to find an optimal deadband width, so as to achieve the best weighted balance between the time duration of nuisance alarms and the delay in detecting abnormal conditions. The proposed method is applicable to non-IID (independent and identically distributed) signals, whereas available design methods are confined to IID signals. Industrial examples are provided to validate the deadband index and the design method.
Keywords
Funding Information
- National Natural Science Foundation of China (61433001)
- Research Fund for the Taishan Scholar Project of Shandong Province of China
- Scientific and Technological Innovation Project of Shandong University of Science and Technology (SDKDYC180359)
This publication has 22 references indexed in Scilit:
- Analysis and design of multimode delay-timersChemical Engineering Research and Design, 2017
- Situation awareness measurement of an ecological interface designed to operator support during alarm floodsInternational Journal of Industrial Ergonomics, 2016
- Reduction of clinically irrelevant alarms in patient monitoring by adaptive time delaysJournal of Clinical Monitoring and Computing, 2015
- Criteria-based alarm flood pattern recognition using historical data from automated production systems (aPS)Mechatronics, 2015
- An Overview of Industrial Alarm Systems: Main Causes for Alarm Overloading, Research Status, and Open ProblemsIEEE Transactions on Automation Science and Engineering, 2015
- Study of generalized delay-timers in alarm configurationJournal of Process Control, 2013
- The Connection of peak alarm rates to plant incidents and what you can do to minimizeProcess Safety Progress, 2012
- Estimation of alarm chatteringJournal of Process Control, 2011
- On expected detection delays for alarm systems with deadbands and delay-timersJournal of Process Control, 2011