Zijiang Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zijiang Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jiandong Wang
Shandong University of Science and Technology
4 shared publications - Donghua Zhou
Southeast University
1 shared publication - Mengyao Wei
College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao 266590, China
1 shared publication Song Gao
Shandong Electric Power Research Institute for State Grid Corporation of China, Jinan, China
1 shared publication- Song Gao
School of Transportation and Vehicle Engineering, Shandong University of Technology, Zibo 255000, China
1 shared publication - Xingzhen Bai
College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao, China
1 shared publication
Latest Publications
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (4) , 1831-1838
Static Gain Estimation for Automatic Generation Control Systems From Historical Ramp Responses
This brief proposes an approach to estimate static gains of dynamic models for automatic generation control systems in coal-fired power generation units. The main idea is to infer static gains of dynamic models from amplitude changes of model inputs and outputs in finite-time ramp responses. First, input and output time sequences are approximated by a few straight lines as piecewise linear representations. Second, finite-time ramp responses are detected as the data segments where inputs and outputs simultaneously move along straight lines with significant amplitude changes. Third, estimated static gains are obtained by solving linear equations of significant amplitude changes in the ramp responses. One technical challenge of selecting the thresholds of significant amplitude changes is resolved by exploiting a relationship among the amplitude change, noise variance, and signal-to-noise ratio. Comparing with a standard system identification approach, the obtained results from the proposed approach can be validated in a convincing manner: ramp responses being found from historical data samples can be confirmed by checking whether data segments of inputs and outputs are actually in straight lines; estimated static gains can be verified by comparing output amplitude changes in the ramp responses with their estimated values. Numerical and industrial examples are provided to support the proposed approach.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (4) , 1831-1838
Static Gain Estimation for Automatic Generation Control Systems From Historical Ramp Responses
This brief proposes an approach to estimate static gains of dynamic models for automatic generation control systems in coal-fired power generation units. The main idea is to infer static gains of dynamic models from amplitude changes of model inputs and outputs in finite-time ramp responses. First, input and output time sequences are approximated by a few straight lines as piecewise linear representations. Second, finite-time ramp responses are detected as the data segments where inputs and outputs simultaneously move along straight lines with significant amplitude changes. Third, estimated static gains are obtained by solving linear equations of significant amplitude changes in the ramp responses. One technical challenge of selecting the thresholds of significant amplitude changes is resolved by exploiting a relationship among the amplitude change, noise variance, and signal-to-noise ratio. Comparing with a standard system identification approach, the obtained results from the proposed approach can be validated in a convincing manner: ramp responses being found from historical data samples can be confirmed by checking whether data segments of inputs and outputs are actually in straight lines; estimated static gains can be verified by comparing output amplitude changes in the ramp responses with their estimated values. Numerical and industrial examples are provided to support the proposed approach.
- 1 July 2020
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 119, 105868
A method to estimate speed droop ratios for primary frequency control responses in power generation units
- 1 July 2020
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 119, 105868
A method to estimate speed droop ratios for primary frequency control responses in power generation units
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4831-4835
A PLR-based method to speed droop ratio estimation for primary frequency control
The performance of primary frequency control (PFC) in power generation units is paramount important for power grids to suppress frequency fluctuations and preserve load-generation balance. The speed droop ratio is the most concerned primary frequency control performance index. This paper proposes a new method to estimate this index by extracting qualitative trends of involved signals. The proposed method is composed of three steps. The first step is to find the data segments including one PFC process from historical data of generated active power of power generation units according to variations in power grid frequency. The second step is to obtain piece-wise linear representations (PLR) of the selected generated active power data segments. The third step is to formulate the stages with PLRs, estimate the amplitude changes response stage, and calculate speed droop ratios for selected data segments. Simulated and industrial examples are provided to illustrate the effectiveness of the proposed method, and compare with two existing methods.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4831-4835
A PLR-based method to speed droop ratio estimation for primary frequency control
The performance of primary frequency control (PFC) in power generation units is paramount important for power grids to suppress frequency fluctuations and preserve load-generation balance. The speed droop ratio is the most concerned primary frequency control performance index. This paper proposes a new method to estimate this index by extracting qualitative trends of involved signals. The proposed method is composed of three steps. The first step is to find the data segments including one PFC process from historical data of generated active power of power generation units according to variations in power grid frequency. The second step is to obtain piece-wise linear representations (PLR) of the selected generated active power data segments. The third step is to formulate the stages with PLRs, estimate the amplitude changes response stage, and calculate speed droop ratios for selected data segments. Simulated and industrial examples are provided to illustrate the effectiveness of the proposed method, and compare with two existing methods.
- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 8093-8103
Indexing and Designing Deadbands for Industrial Alarm Signals
Alarm systems play critically important roles for the safe and efficient operation of industrial plants, but they often suffer from too many nuisance alarms. Deadbands are widely used in industrial alarm systems to reduce the number of nuisance alarms. This paper formulates an index to determine whether deadbands are suitable for removing nuisance alarms of an analog signal, and proposes a method to design the deadband width. First, the deadband index is defined from two metrics, namely, normalized alarm durations and normalized alarm deviations. If the index is larger than $45^{\circ}$ , as indicated by a hypothesis test, then nuisance alarms are associated with large/small normalized alarm durations/deviations, so that deadbands are suitable. Second, a design method is proposed to find an optimal deadband width, so as to achieve the best weighted balance between the time duration of nuisance alarms and the delay in detecting abnormal conditions. The proposed method is applicable to non-IID (independent and identically distributed) signals, whereas available design methods are confined to IID signals. Industrial examples are provided to validate the deadband index and the design method.- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 8093-8103
Indexing and Designing Deadbands for Industrial Alarm Signals
Alarm systems play critically important roles for the safe and efficient operation of industrial plants, but they often suffer from too many nuisance alarms. Deadbands are widely used in industrial alarm systems to reduce the number of nuisance alarms. This paper formulates an index to determine whether deadbands are suitable for removing nuisance alarms of an analog signal, and proposes a method to design the deadband width. First, the deadband index is defined from two metrics, namely, normalized alarm durations and normalized alarm deviations. If the index is larger than $45^{\circ}$ , as indicated by a hypothesis test, then nuisance alarms are associated with large/small normalized alarm durations/deviations, so that deadbands are suitable. Second, a design method is proposed to find an optimal deadband width, so as to achieve the best weighted balance between the time duration of nuisance alarms and the delay in detecting abnormal conditions. The proposed method is applicable to non-IID (independent and identically distributed) signals, whereas available design methods are confined to IID signals. Industrial examples are provided to validate the deadband index and the design method.