Abstract
This paper proposes a novel approach for the control of a permanent magnet synchronous machine with a quadruple 3-phase star-connected winding configuration after a short circuit-fault in one voltage source inverter. The approach includes an adaption of the closed-loop current control that allows to proceed the operation of the faulty unit without the need to adapt the reference currents. This allows an operation of the faulty drive with increased post-fault mean torque. Additionally, a strategy for post-fault torque error compensation is proposed, which can be used to reduce the torque ripple while the load distribution is better balanced. Results are respectively compared to the case when applying a symmetric short circuit to the faulty unit, which is the conventional strategy in case of a transistor short circuit-fault. The current limit of the drive is considered in all cases. The benefits of the approach are validated through experimental tests.