Application of a Nonlinear Slug Test Model
Author:
- 1 September 2001
- journal article
- Published by Wiley in Groundwater
- Vol. 39 (5) , 737-744
Abstract
Knowledge of the hydraulic conductivity distribution is of utmost importance in understanding the dynamics of an aquifer and in planning the consequences of any action taken upon that aquifer. Slug tests have been used extensively to measure hydraulic conductivity in the last 50 years since Hvorslev's (1951) work. A general nonlinear model based on the Navier‐Stokes equation, nonlinear frictional loss, non‐Darcian flow, acceleration effects, radius changes in the wellbore, and a Hvorslev model for the aquifer has been implemented in this work. The nonlinear model has three parameters: β, which is related primarily to radius changes in the water column; A, which is related to the nonlinear head losses; and K, the hydraulic conductivity. An additional parameter has been added representing the initial velocity of the water column at slug initiation and is incorporated into an analytical solution to generate the first time step before a sequential numerical solution generates the remainder of the time solution. Corrections are made to the model output for acceleration before it is compared to the experimental data. Sensitivity analysis and least squares fitting are used to estimate the aquifer parameters and produce some diagnostic results, which indicate the accuracy of the fit. Finally, an example of field data has been presented to illustrate the application of the model to data sets that exhibit nonlinear behavior. Multiple slug tests should be taken at a given location to test for nonlinear effects and to determine repeatability.Keywords
This publication has 10 references indexed in Scilit:
- Floods, channel change, and the hyporheic zoneWater Resources Research, 1999
- A nonlinear model for analysis of slug‐test dataWater Resources Research, 1998
- Improving the Quality of Parameter Estimates Obtained from Slug TestsGroundwater, 1996
- Sensitivity analysis of slug tests. Part 1. The slugged wellJournal of Hydrology, 1995
- SUPRPUMP: An Interactive Program for Well Test Analysis and DesignGroundwater, 1992
- A Critique of the Hvorslev Method for Slug Test Analysis: The Fully Penetrating WellGroundwater Monitoring & Remediation, 1989
- Sensitivity Analysis of Ground-Water Models1987
- A slug test for determining hydraulic conductivity of unconfined aquifers with completely or partially penetrating wellsWater Resources Research, 1976
- Determining aquifer transmissivity by means of well response tests: The underdamped caseWater Resources Research, 1976
- Response of a finite‐diameter well to an instantaneous charge of waterWater Resources Research, 1967