Investigating Low-Dose Image Quality in Whole-Body Pediatric 18F-FDG Scans Using Time-of-Flight PET/MRI
- 1 June 2020
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 62 (1) , 123-130
Abstract
In this study we investigate the diagnostic performance of whole-body F18-FDG imaging using a simultaneous PET/MRI scanner with Time-of-Flight (TOF) capability for low-dose clinical imaging of pediatric patients. In addition to clinically acquired image data using a dosing regimen of 3.7 MBq/kg, images from simulated low-dose regimens (1.9 MBq/kg – 0.41 MBq/kg) were evaluated using several metrics: standardized uptake value (SUV) quantitation, qualitative image quality and lesion detectability. Methods: Low-dose images were generated by truncating the list-mode PET data. A total of 60 image volumes were analyzed, generated from 12 patient scans. Changes in PET quantitation for low-dose images were assessed using ROI analysis of healthy tissue and suspected lesions. Three pediatric radiologists reviewed the image volumes blinded to the dose level. Qualitative image quality was assessed based on Likert scoring. Radiologists were also asked to identify suspected lesions within the liver for PET-only and fused PET/MR images. The lesion detectability was measured using a receiver operator characteristic study and quantified using a free response receiving operator characteristic (FROC) methodology to assess changes in performance for low-dose images. Results: Our analysis of ROI quantitation shows that SUV values remain stable down to 1/3 dose (1.2 MBq/kg). Likert scoring of fused PET/MRI images showed no noticeable trend with dose level, however scores of PET-only images were lower for low-dose scans, with a 12% reduction for 1/3 dose images compared to full-dose. There was minimal change in lesion total lesion count for different does levels, however all three readers had an increase in false-negatives for 1/3 dose images compared to full-dose. Using the FROC methodology to quantify human observer lesion detection performance, no significant differences were observed for the three dosing levels when using the averaged reader data (all p values > 0.103). The FROC performance for fused PET/MR images was higher for all readers compared to PET alone. Conclusion: Reductions to the lowest recommended pediatric dosing regimens are possible when using PET/MR. Data suggests that administered dose can be decreased to 2.6 MBq/kg, a 30% reduction in PET activity leading to a corresponding reduction in absorbed dose.Keywords
This publication has 39 references indexed in Scilit:
- A Brief History of Free-Response Receiver Operating Characteristic Paradigm Data AnalysisAcademic Radiology, 2013
- Repeatability of 18F-FDG Uptake Measurements in Tumors: A MetaanalysisJournal of Nuclear Medicine, 2012
- Ultra-low dose CT attenuation correction for PET/CTPhysics in Medicine & Biology, 2011
- An Approach for Balancing Diagnostic Image Quality with Cancer Risk: Application to Pediatric Diagnostic Imaging of 99mTc-Dimercaptosuccinic AcidJournal of Nuclear Medicine, 2011
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Evaluation of Optimal Acquisition Duration or Injected Activity for Pediatric 18F-FDG PET/CTJournal of Nuclear Medicine, 2011
- Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PETJournal of Nuclear Medicine, 2011
- Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective reviewPediatric Radiology, 2009
- From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid TumorsJournal of Nuclear Medicine, 2009
- Risks Associated with Low Doses and Low Dose Rates of Ionizing Radiation: Why Linearity May Be (Almost) the Best We Can DoRadiology, 2009