Evaluation of Optimal Acquisition Duration or Injected Activity for Pediatric 18F-FDG PET/CT
Authors:
Open Access
- 16 June 2011
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 52 (7) , 1028-1034
Abstract
Pediatric 18F-FDG dosing and acquisition durations are generally based on coarse extrapolation from adult guidelines. This study sought to determine whether shorter acquisition durations or a lower 18F-FDG injected activity could be used for pediatric 18F-FDG PET/CT examinations while maintaining diagnostic utility. Reduction of overall scan time potentially reduces motion artifacts, improves patient comfort, and decreases length of sedation. Alternatively, decreased 18F-FDG dose minimizes radiation risk. Methods: Fourteen whole-body 18F-FDG PET/CT examinations were performed on 13 patients (weight, 13–109 kg; age range, 1–23 y) with a weight-based injected activity (5.3 MBq/kg [0.144 mCi/kg]), fixed acquisition durations (3 min/field of view [FOV] if < 22 kg, 5 min/FOV if > 22 kg), and list-mode acquisition. For each examination, the list-mode data were truncated to form multiple datasets with shorter acquisition durations down to a minimum of 1 min/FOV (i.e., 1, 2, 3, 4, and 5 min/FOV data were formed from single 5 min/FOV acquisition). Fifty-six image volumes were generated, randomized, and reviewed in a masked manner with corresponding CT image volumes by 5 radiologists. Overall, subjective adequacy and objective lesion detection accuracy by body region were evaluated. Results: All examinations with maximum acquisition duration were graded as adequate and were used as the reference standard for detection accuracy. For patients less than 22 kg, 1 of the 3 PET/CT examinations was graded as inadequate for clinical tasks when acquisition duration was reduced to 2 min/FOV, and all examinations were graded as inadequate when reduced to 1 min/FOV. For patients more than 22 kg, all 3–5 min/FOV studies were graded as adequate, and 2 of the 9 studies were graded as inadequate for 2 min/FOV studies. Lesion detection accuracy was perfect for acquisition times between 3 min/FOV and 5 min/FOV for all regions of the body. However, lesion detection became less accurate when imaging acquisition time was reduced more than 40%. Conclusion: Evaluation of image volumes generated from simulated shorter acquisition durations suggests that imaging times for larger patients (>22 kg) can be reduced from 5 min/FOV to 3 min/FOV without a loss of diagnostic utility. Using decreased acquisition times as a surrogate for 18F-FDG dose, 18F-FDG dose can be reduced by approximately 40% when all patients were scanned for 5 min/FOV.Keywords
This publication has 16 references indexed in Scilit:
- Pediatric Radiopharmaceutical Administered Doses: 2010 North American Consensus GuidelinesJournal of Nuclear Medicine, 2011
- Injected Dose in Pediatric PETJournal of Nuclear Medicine, 2010
- Improved Dose Regimen in Pediatric PETJournal of Nuclear Medicine, 2010
- Weight-Based, Low-Dose Pediatric Whole-Body PET/CT ProtocolsJournal of Nuclear Medicine, 2009
- Dosimetry of Pediatric PET/CTJournal of Nuclear Medicine, 2009
- Administered Radiopharmaceutical Doses in Children: A Survey of 13 Pediatric Hospitals in North America: TABLE 1Journal of Nuclear Medicine, 2008
- Guidelines for the use of PET–CT in childrenNuclear Medicine Communications, 2008
- Performance of the new generation of whole-body PET/CT scanners: Discovery STE and Discovery VCTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- The new EANM paediatric dosage cardEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents countsIEEE Transactions on Nuclear Science, 1990