Digital vs manual axis marking for toric phakic intraocular lens alignment: prospective randomized intraindividual trial
- 1 January 2025
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (1) , 23-30
Abstract
Purpose: To compare visual and refractive outcomes and postoperative axis alignment for toric implantable collamer lens (ICL) implantation in astigmatic myopia using manual vs digital marking techniques. Setting: Department of Ophthalmology, Medical University of Graz, Graz, Austria. Design: Prospective randomized single-centered intraindividual comparison. Methods: Patients undergoing bilateral toric ICL implantation for myopia with astigmatism ≥0.5 diopters (D) were enrolled. Patients received both marking techniques, and randomization was performed. Postoperative retroillumination photography assessed axis alignment, and visual and refractive parameters were evaluated. Duration of the surgeries was recorded. Results: The study included 20 patients and 40 eyes. Preoperative visual and refractive parameters showed no significant differences. Postoperatively, residual astigmatism (P = .824) and spherical equivalent (P = .309) were comparable. No notable differences between right and left eyes in preoperative (P = .371) and postoperative (P = .824) astigmatism were observed. Although slight, corrected distance visual acuity (CDVA) increased in both groups postoperatively (P = .381). Gain in CDVA was comparable between marking techniques (P = .637). Safety and efficacy indices were comparable (P = .991 and P = .189, respectively). Postoperative axial misalignment was 2.8 ± 3.1 degrees in the digital- and 4.4 ± 5.1 degrees in the manual group (P = .260). Vector analysis showed no significant differences between manual and digital marking. Duration remained uninfluenced by the marking technique (P = .970) and side of surgery (P = .682). Conclusions: Digital and manual marking techniques provided comparable results in axis alignment, surgical duration, and visual and refractive outcomes. Both methods were viable for precise axis alignment, with digital marking offering a potential advantage in efficacy.Keywords
This publication has 19 references indexed in Scilit:
- Short-term clinic observation of misalignment and rotational stability after implantable collamer lens implantationGraefe's Archive for Clinical and Experimental Ophthalmology, 2022
- Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantationInternational Ophthalmology, 2022
- Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker systemInternational Ophthalmology, 2020
- Toric IOL positioning with a no-touch head-up display axis alignmentInternational Ophthalmology, 2019
- Evaluation of an intraoperative toric intraocular lens alignment system using an image-guided systemJournal of Cataract & Refractive Surgery, 2019
- Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantationJournal of Cataract & Refractive Surgery, 2017
- Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatismJournal of Cataract & Refractive Surgery, 2014
- Factors affecting rotation of a posterior chamber collagen copolymer toric phakic intraocular lensJournal of Cataract & Refractive Surgery, 2012
- Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bagJournal of Cataract & Refractive Surgery, 2012
- Astigmatism analysis by the Alpins methodJournal of Cataract & Refractive Surgery, 2001