Evaluation of an intraoperative toric intraocular lens alignment system using an image-guided system
Authors:
- 1 September 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (9) , 1234-1238
Abstract
To evaluate an intraoperative toric intraocular lens (IOL) alignment system using a dedicated operating microscope with an image-guided system without preoperative corneal marking. Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. Prospective case series. In this prospective study, a new operating microscope system was used for cataract surgery (toric IOL alignment system of the OPMI Lumera 700 microscope and CALLISTO eye software). This system allows toric IOL alignment by matching limbal vessels from a preoperative photograph with the live image of the microscope. The preoperative photograph was taken with IOLMaster 500, which included a "Reference Image Attachment" system (red-free image), and this was used to track and follow the eye during surgery. After surgery, rotational alignment was assessed and compared with the preoperative axis calculation. At 1 hour postoperatively, a retroilluminaton photograph was taken, and then rotational alignment was compared with the preoperative axis calculation to see the rotational stability. Fifty eyes of 50 patients were included. The feasibility of the intraoperative marking was high. Deviation between the postoperative (at the end of surgery in the operating room) and aimed IOL axes was 0.52 degrees ± 0.56 (SD). The deviation between 1 hour postoperatively and the aimed IOL axes was 5.10 ± 4.45 degrees. Intraoperative toric IOL alignment using an image-guided system was an accurate and fast procedure resulting in precise toric IOL alignment, and the system simplified the positioning of toric IOLs. There was a slight rotation of IOLs shortly after surgery (within the first hour).Keywords
This publication has 15 references indexed in Scilit:
- Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgeryJournal of Cataract & Refractive Surgery, 2017
- Toric outcomes: Computer-assisted registration versus intraoperative aberrometryJournal of Cataract & Refractive Surgery, 2017
- Evaluation of Rotation and Visual Outcomes After Implantation of Monofocal and Multifocal Toric Intraocular LensesJournal of Refractive Surgery, 2015
- Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complicationsJournal of Cataract & Refractive Surgery, 2013
- Evaluation of 4 corneal astigmatic marking methodsJournal of Cataract & Refractive Surgery, 2012
- Residual astigmatism produced by toric intraocular lens rotationJournal of Cataract & Refractive Surgery, 2011
- Accuracy of toric intraocular lens implantation in cataract and refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- New Axis-Marking Method for a Toric Intraocular Lens: Mapping MethodJournal of Refractive Surgery, 2011
- Simplified system of marking the cornea for a toric intraocular lensJournal of Cataract & Refractive Surgery, 2009
- Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2008