Effect of gap size on flange face corrosion
Open Access
- 4 April 2024
- journal article
- research article
- Published by Wiley in Materials and Corrosion
- Vol. 76 (6) , 833-850
Abstract
Bolted flanged joints play a critical role in offshore wind turbine tower structures, serving as integral components that connect various sections of the tower. This research study employs electrochemical techniques to investigate the effect of gap dimensions, which determine the crevice gap thickness and crevice depth, on corrosion behavior of 321 stainless steel flange sample plates in a 3.5 wt% NaCl solution at 50°C. Gaskets are used in this study to create gaps between two flange surfaces. A novel fixture is utilized to simulate the applied stress on the gasket, fluid flow within the fixture, and the geometric aspects of the gasket and flange. The findings reveal that increasing the gap thickness from 1.58 to 6.35 mm results in a rise in the general corrosion rate of the flange surface from 0.09 to 1.03 mm y−1, and crevice corrosion initiation time increases from 0.23 to 3.12 h. Furthermore, reducing the crevice depth (d) from 7.49 to 0 mm leads to a decrease in the general corrosion rate from 0.09 mm y−1 to 0.04 µm y−1, and cases with d = 3.81 and d = 0 mm show no observable crevice corrosion after potentiostatic tests.Keywords
This publication has 33 references indexed in Scilit:
- Study on the passive behavior of 304 stainless steel under temperature variationMaterials and Corrosion, 2024
- Damage detection of flange bolts in wind turbine towers using dynamic strain responsesJournal of Civil Structural Health Monitoring, 2022
- The crevice corrosion behaviour of stainless steel in sodium chloride solutionCorrosion Science, 2011
- An experimental study of crevice corrosion behaviour of 316L stainless steel in artificial seawaterCorrosion Science, 2010
- Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluidsCorrosion Science, 2009
- A critical crevice solution and IR drop crevice corrosion modelCorrosion Science, 2008
- The role of electrolyte concentration on crevice corrosion of pure nickelMaterials and Corrosion, 2007
- Recent Developments In Elevated Temperature Gasket Evaluation1992
- The significance of the local electrode potential within pits, crevices and cracksCorrosion Science, 1989
- Korrosion an Dichtflächen von FlanschverbindungenMaterials and Corrosion, 1960