Marginal Misfit Assessment in Common Restorative Materials for Cement-Retained Fixed Implant Prostheses: An In Vitro Comparative Study.
Open Access
- 1 April 2026
- journal article
- Vol. 12 (2) , e70318
Abstract
To assess the vertical discrepancy at the abutment-crown interface (ACI) for cement-retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials-metal-ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)-were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated-measures ANOVA, followed by Bonferroni post-hoc test and paired t-test. The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant (p = 0.980). Significant differences were found in the IC group between MZ and VZ (p = 0.016) and between MC and VZ (p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4). Cement-retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal-ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.Keywords
This publication has 61 references indexed in Scilit:
- Fit of zirconia all-ceramic crowns with different cervical margin designs, before and after porcelain firing and glazingDental Materials Journal, 2014
- Performance of conical abutment (Morse Taper) connection implants: A systematic reviewJournal of Biomedical Materials Research Part A, 2013
- Marginal Discrepancy of Monolithic and Veneered All-Ceramic Crowns on Titanium and Zirconia Implant Abutments Before and After Adhesive Cementation: A Scanning Electron Microscopy AnalysisThe International Journal of Oral and Maxillofacial Implants, 2013
- A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementationThe Journal of Prosthetic Dentistry, 2009
- Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs.2009
- Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniquesThe Journal of Prosthetic Dentistry, 2006
- Influence of fluoride content and pH on the corrosion resistance of titanium and its alloysBiomaterials, 2002
- Determination of the minimum number of marginal gap measurements required for practical in vitro testingThe Journal of Prosthetic Dentistry, 2000
- Considerations in measurement of marginal fitThe Journal of Prosthetic Dentistry, 1989
- The estimation of cement film thickness by an in vivo techniqueBritish Dental Journal, 1971