Pedro Diaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro Diaz has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Maria Jesus Suarez
Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry Complutense University of Madrid Madrid Spain
6 shared publications - Seyed Ali Mosaddad
Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
5 shared publications - Jesús Peláez
Adjunct Professor, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
3 shared publications Antonio Martin
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
2 shared publicationsBarbara Miegimolle
Department of Clinic Grade Dentistry, Faculty of Odontology, European University of Madrid, Madrid, Spain
2 shared publications- Celia Tobar
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (4) , e70413
Initial Cytotoxicity of Additively and Subtractively Manufactured Resin‐Based Materials for Interim Fixed Dental Prostheses: An In Vitro Study
Objectives: To compare the initial cytotoxic response of additively manufactured (AM) and subtractively manufactured (SM) resin‐based materials for interim fixed dental prostheses (FDPs) under indirect and direct in vitro exposure conditions. Material and Methods: A total of 216 standardized resin discs were fabricated from AM resins (Group P, n = 108) and SM polymethyl methacrylate (PMMA)‐based resins (Group M, n = 108). L929 mouse fibroblasts were used as the biological model, with a negative control group (Group C, n = 36). After 24 h of cell attachment, cell viability was assessed after 72 h under two conditions: indirect exposure to resin eluates and direct contact with resin discs. Viability was quantified by crystal violet staining. Data were analyzed using Kruskal–Wallis tests followed by Dunn's pairwise post hoc comparisons ( α = 0.05). Results: In the indirect assay, Group M showed 87% cell survival relative to the control, whereas Group P showed 65%; in the direct assay, values were 89% and 48%, respectively. Significant differences were observed among pooled groups in both assays ( p < 0.001). Based on ISO 10993‐5 thresholds, Group P was classified as slightly cytotoxic in the indirect assay and moderately cytotoxic in the direct assay, whereas Group M remained within the non‐cytotoxic to slightly cytotoxic range. Group P showed significantly lower cell viability than Group M in both assays (adjusted p < 0.001), while no statistically significant differences were detected within each manufacturing category (adjusted p > 0.05). Conclusions: At 72 h, the tested AM resins showed significantly lower cell viability than the tested SM PMMA‐based resins under the present in vitro conditions. Clinical Significance: The lower cell viability observed for the tested 3D‐printed interim materials under short‐term in vitro conditions highlights the need for caution when extrapolating 72‐h cell‐viability findings to clinical performance and supports further standardized long‐term in vitro and in vivo investigations.
- 16 July 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (4) , e70413
Open AccessInitial Cytotoxicity of Additively and Subtractively Manufactured Resin‐Based Materials for Interim Fixed Dental Prostheses: An In Vitro Study
Objectives: To compare the initial cytotoxic response of additively manufactured (AM) and subtractively manufactured (SM) resin‐based materials for interim fixed dental prostheses (FDPs) under indirect and direct in vitro exposure conditions. Material and Methods: A total of 216 standardized resin discs were fabricated from AM resins (Group P, n = 108) and SM polymethyl methacrylate (PMMA)‐based resins (Group M, n = 108). L929 mouse fibroblasts were used as the biological model, with a negative control group (Group C, n = 36). After 24 h of cell attachment, cell viability was assessed after 72 h under two conditions: indirect exposure to resin eluates and direct contact with resin discs. Viability was quantified by crystal violet staining. Data were analyzed using Kruskal–Wallis tests followed by Dunn's pairwise post hoc comparisons ( α = 0.05). Results: In the indirect assay, Group M showed 87% cell survival relative to the control, whereas Group P showed 65%; in the direct assay, values were 89% and 48%, respectively. Significant differences were observed among pooled groups in both assays ( p < 0.001). Based on ISO 10993‐5 thresholds, Group P was classified as slightly cytotoxic in the indirect assay and moderately cytotoxic in the direct assay, whereas Group M remained within the non‐cytotoxic to slightly cytotoxic range. Group P showed significantly lower cell viability than Group M in both assays (adjusted p < 0.001), while no statistically significant differences were detected within each manufacturing category (adjusted p > 0.05). Conclusions: At 72 h, the tested AM resins showed significantly lower cell viability than the tested SM PMMA‐based resins under the present in vitro conditions. Clinical Significance: The lower cell viability observed for the tested 3D‐printed interim materials under short‐term in vitro conditions highlights the need for caution when extrapolating 72‐h cell‐viability findings to clinical performance and supports further standardized long‐term in vitro and in vivo investigations.
- Open Access
- 1 April 2026
- Vol. 12 (2) , e70318
Marginal Misfit Assessment in Common Restorative Materials for Cement-Retained Fixed Implant Prostheses: An In Vitro Comparative Study.
To assess the vertical discrepancy at the abutment-crown interface (ACI) for cement-retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials-metal-ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)-were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated-measures ANOVA, followed by Bonferroni post-hoc test and paired t-test. The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant (p = 0.980). Significant differences were found in the IC group between MZ and VZ (p = 0.016) and between MC and VZ (p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4). Cement-retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal-ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.
- 1 April 2026
- Vol. 12 (2) , e70318
Open AccessMarginal Misfit Assessment in Common Restorative Materials for Cement-Retained Fixed Implant Prostheses: An In Vitro Comparative Study.
To assess the vertical discrepancy at the abutment-crown interface (ACI) for cement-retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials-metal-ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)-were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated-measures ANOVA, followed by Bonferroni post-hoc test and paired t-test. The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant (p = 0.980). Significant differences were found in the IC group between MZ and VZ (p = 0.016) and between MC and VZ (p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4). Cement-retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal-ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.
- Open Access
- 25 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (2) , e70318
Marginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study
Objectives: To assess the vertical discrepancy at the abutment–crown interface (ACI) for cement‐retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. Materials and Methods: A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials—metal‐ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)—were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated‐measures ANOVA, followed by Bonferroni post‐hoc test and paired t ‐test. Results: The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant ( p = 0.980). Significant differences were found in the IC group between MZ and VZ ( p = 0.016) and between MC and VZ ( p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4). Conclusions: Cement‐retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal‐ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.
- 25 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (2) , e70318
Open AccessMarginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study
Objectives: To assess the vertical discrepancy at the abutment–crown interface (ACI) for cement‐retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. Materials and Methods: A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials—metal‐ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)—were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated‐measures ANOVA, followed by Bonferroni post‐hoc test and paired t ‐test. Results: The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant ( p = 0.980). Significant differences were found in the IC group between MZ and VZ ( p = 0.016) and between MC and VZ ( p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4). Conclusions: Cement‐retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal‐ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.
- Top Cited PapersOpen Access
- 21 February 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (1) , 30-39
Do color stability and translucency differ between 3D printed and milled resin-based fixed dental restorations? A systematic review and meta-analysis
- 21 February 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (1) , 30-39
Top Cited PapersOpen AccessDo color stability and translucency differ between 3D printed and milled resin-based fixed dental restorations? A systematic review and meta-analysis
- Top Cited PapersOpen Access
- 19 October 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-13
What is the prevalence of peri-implantitis? A systematic review and meta-analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.53% (95% CI 12.87–26.19) at the patient-level, and 12.53% (95% CI 11.67–13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- 19 October 2022
- Published by Springer Nature in BMC Oral Health
- Vol. 22 (1) , 1-13
Top Cited PapersOpen AccessWhat is the prevalence of peri-implantitis? A systematic review and meta-analysis
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.53% (95% CI 12.87–26.19) at the patient-level, and 12.53% (95% CI 11.67–13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.
- Open Access
Evaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection
The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student’s paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.
Open AccessEvaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection
The precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface. Scanning electron microscopes (SEM) were used to geometrically measure the marginal vertical discrepancy of a total of 80 specimens, classified into eight categories, according to the implant system and abutment. The data were statistically analyzed by Student’s paired t test, one-way and two-way ANOVA with the Bonferroni-Holm correction at the significance level of p = 0.05. Milled titanium abutments demonstrated the lowest misfit values in the implant systems analyzed. The marginal fit of all the groups was within the clinically acceptable range for implant prostheses.
- 1 July 2010
- Published by Elsevier in Toxicology Letters
- Vol. 196, S287-287
Toxicological profile by Jatropha curcas L.
- 1 July 2010
- Published by Elsevier in Toxicology Letters
- Vol. 196, S287-287
Toxicological profile by Jatropha curcas L.