Determination of Oxomemazine in Human Plasma by Capillary LC‐ESI‐MS
- 1 February 2007
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 30 (3) , 393-403
Abstract
A method based on on‐line solid phased extraction capillary liquid chromatography‐electrospray ionization‐mass spectrometry (SPE‐capLC‐ESI‐MS) has been developed for the determination of oxomemazine in human plasma. Prior to injection, 0.5 mL of plasma spiked with metronidazole (internal standard) was mixed with ammonium formate buffer and methyl orange, which served as an ion pair reagent for effective chloroform liquid–liquid extraction. The employment of methyl orange as an ion pair reagent doubled the extraction efficiency, as compared to not using methyl orange. In preliminary experiments, conventional LC‐UV instrumentation was employed. However, it was found that employing a capillary column with an inner diameter of 0.3 mm increased the sensitivity by a factor of ∼100, when injecting the same mass of analyte. Incorporating an easily automated reversed phase column switching system with SPE made it possible to inject up to 100 µL of solution, and the total analysis time was 5 minutes. The method was validated in the range 3 to 30 ng/mL oxomemazine, yielding a correlation coefficient of 0.99 (r2). The within‐assay and between‐assay precisions were between 6.7 and 12% and 6.8 and 7.4%, respectively. The method was used to determine the amount of oxomemazine in a healthy female 20 hours after an intake of 1 teaspoon (approximately 1 mL) of the cough syrup Toplexil®, which contains 0.033 g oxomemazine per 100 mL syrup. Oxomemazine was detected, and the concentration was calculated to 2.0 ng/mL plasma.Keywords
This publication has 7 references indexed in Scilit:
- Determination of bradykinin and arg‐bradykinin in rat muscle tissue by microdialysis and capillary column‐switching liquid chromatography with mass spectrometric detectionJournal of Separation Science, 2005
- Extractive Spectrophotometric Methods for the Determination of Oxomemazine Hydrochloride in Bulk and Pharmaceutical Formulations Using Bromocresol Green, Bromocresol Purple and Bromophenol BlueArchiv der Pharmazie, 2005
- Determination of perfluorooctane sulfonate and perfluorooctanoic acid in human plasma by large volume injection capillary column switching liquid chromatography coupled to electrospray ionization mass spectrometryJournal of Separation Science, 2004
- Fast and sensitive determination of urinary 1-hydroxypyrene by packed capillary column switching liquid chromatography coupled to micro-electrospray time-of-flight mass spectrometryJournal of Chromatography B, 2003
- Determination of rotenone in river water utilizing packed capillary column switching liquid chromatography with UV and time-of-flight mass spectrometric detectionJournal of Chromatography A, 2003
- Stability - Indicating Hplc Assay for Paracetamol, Guaiphenesin, Sodium Benzoate and Oxomemazine in Cough Syrup.Analytical Letters, 1994
- Development of a standardized analysis strategy for basic drugs, using ion-pair extraction and high-performance liquid chromatography — III. Analysis of pharmaceutical dosage formsJournal of Pharmaceutical and Biomedical Analysis, 1984