Histopathological Verification of the Diagnostic Performance of the EU-TIRADS Classification of Thyroid Nodules—Results of a Multicenter Study Performed in a Previously Iodine-Deficient Region
Authors:
- Katarzyna Dobruch-SobczakKDKatarzyna Dobruch-Sobczak
- Zbigniew AdamczewskiZAZbigniew Adamczewski
- Ewelina Szczepanek-ParulskaESEwelina Szczepanek-Parulska
- Bartosz MigdaBMBartosz Migda
- Kosma WolińskiKWKosma Woliński
- Agnieszka KrauzeAKAgnieszka Krauze
- Piotr ProstkoPPPiotr Prostko
- Marek RuchałaMRMarek Ruchała
- Andrzej LewińskiAndrzej Lewiński
- Wiesław JakubowskiWJWiesław Jakubowski
- Marek DedecjusMDMarek Dedecjus
Open Access
- 25 October 2019
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (11) , 1781
Abstract
Background: To validate the European Thyroid Imaging and Reporting Data System EU-TIRADS classification in a multi-institutional database of thyroid nodules by analyzing the obtained scores and histopathology results. Methods: A total of 842 thyroid lesions (613 benign, 229 malignant) were identified in 428 patients (mean age 62.7 years) and scored according to EU-TIRADS, using ultrasound examination. In all tumors, histopathological verification was performed. Results: In EU-TIRADS 2 (154 nodules) all nodules were benign; in EU-TIRADS 3, only 3/93 malignancies were identified. In EU-TIRADS 4, 12/103 were malignant, and in EU-TIRADS 5 (278 benign vs. 214 malignant). The malignant nodules that would not have qualified for biopsy were: EU-TIRADS 3, 2/3 (67%) malignancies were <20 mm, in EU-TIRADS 4, 7/12 (58%) were <15 mm. In EU-TIRADS 5, 72/214 (34%) were <10 mm; in total, 81/229 (36%) malignant lesions would have been missed. The cutoff between EU-TIRADS 3/4 had sensitivity of 100%, specificity of 25.1%. Using cutoff for EU-TIRADS 5, 93.4%, 54.6%, respectively. Conclusion: The application of EU-TIRADS guidelines allowed us to achieve moderate specificity. The vast majority of malignancies in EU-TIRADS 3, 4, and 5 would not have been recommended for biopsy because having a smaller size than that proposed classification.Keywords
This publication has 34 references indexed in Scilit:
- Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological resultsPolish Journal of Radiology, 2018
- Comparison of Performance Characteristics of American College of Radiology TI-RADS, Korean Society of Thyroid Radiology TIRADS, and American Thyroid Association GuidelinesAmerican Journal of Roentgenology, 2018
- European Thyroid Association Guidelines for Ultrasound Malignancy Risk Stratification of Thyroid Nodules in Adults: The EU-TIRADSEuropean Thyroid Journal, 2017
- The thyroid gland in postmenopausal women: physiology and diseasesMenopause Review-Przeglad Menopauzalny, 2017
- Predicting malignancy in thyroid nodules: feasibility of a predictive model integrating clinical, biochemical, and ultrasound characteristicsThyroid Research, 2016
- American Association of Clinical Endocrinologists, American College of Endocrinology, and Associazione Medici Endocrinologi Medical Guidelines for Clinical Practice for the Diagnosis and Management of Thyroid Nodules - 2016 Update AppendixEndocrine Practice, 2016
- A multi-centre pilot study of iodine status in UK schoolchildren, aged 8–10 yearsEuropean Journal of Nutrition, 2015
- Korea's Thyroid-Cancer “Epidemic” — Screening and OverdiagnosisNew England Journal of Medicine, 2014
- Usefulness of different ultrasound features of malignancy in predicting the type of thyroid lesions: a meta‑analysis of prospective studiesPolish Archives of Internal Medicine, 2014
- An Ultrasonogram Reporting System for Thyroid Nodules Stratifying Cancer Risk for Clinical ManagementThe Journal of Clinical Endocrinology & Metabolism, 2009