AKAgnieszka Krauze

Agnieszka Krauze

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Agnieszka Krauze has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    S-Detect Software vs. EU-TIRADS Classification: A Dual-Center Validation of Diagnostic Performance in Differentiation of Thyroid Nodules

    by Ewelina Szczepanek-Parulska, Kosma Wolinski, Katarzyna Dobruch-Sobczak, Patrycja Antosik, Anna Ostalowska, Agnieszka Krauze, Bartosz Migda, Agnieszka Zylka, Malgorzata Lange-Ratajczak, Tomasz Banasiewicz, et al.

    Computer-aided diagnosis (CAD) and other risk stratification systems may improve ultrasound image interpretation. This prospective study aimed to compare the diagnostic performance of CAD and the European Thyroid Imaging Reporting and Data System (EU-TIRADS) classification applied by physicians with S-Detect 2 software CAD based on Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and combinations of both methods (MODELs 1 to 5). In all, 133 nodules from 88 patients referred to thyroidectomy with available histopathology or with unambiguous results of cytology were included. The S-Detect system, EU-TIRADS, and mixed MODELs 1–5 for the diagnosis of thyroid cancer showed a sensitivity of 89.4%, 90.9%, 84.9%, 95.5%, 93.9%, 78.9% and 93.9%; a specificity of 80.6%, 61.2%, 88.1%, 53.7%, 73.1%, 89.6% and 80.6%; a positive predictive value of 81.9%, 69.8%, 87.5%, 67%, 77.5%, 88.1% and 82.7%; a negative predictive value of 88.5%, 87.2%, 85.5%, 92.3%, 92.5%, 81.1% and 93.1%; and an accuracy of 85%, 75.9%, 86.5%, 74.4%, 83.5%, 84.2%, and 87.2%, respectively. Comparison showed superiority of the similar MODELs 1 and 5 over other mixed models as well as EU-TIRADS and S-Detect used alone (p-value < 0.05). S-Detect software is characterized with high sensitivity and good specificity, whereas EU-TIRADS has high sensitivity, but rather low specificity. The best diagnostic performance in malignant thyroid nodule (TN) risk stratification was obtained for the combined model of S-Detect (“possibly malignant” nodule) and simultaneously obtaining 4 or 5 points (MODEL 1) or exactly 5 points (MODEL 5) on the EU-TIRADS scale.


  • Open Access

    Histopathological Verification of the Diagnostic Performance of the EU-TIRADS Classification of Thyroid Nodules—Results of a Multicenter Study Performed in a Previously Iodine-Deficient Region

    by Katarzyna Dobruch-Sobczak, Zbigniew Adamczewski, Ewelina Szczepanek-Parulska, Bartosz Migda, Kosma Woliński, Agnieszka Krauze, Piotr Prostko, Marek Ruchała, Andrzej Lewiński, Wiesław Jakubowski, et al.

    Background: To validate the European Thyroid Imaging and Reporting Data System EU-TIRADS classification in a multi-institutional database of thyroid nodules by analyzing the obtained scores and histopathology results. Methods: A total of 842 thyroid lesions (613 benign, 229 malignant) were identified in 428 patients (mean age 62.7 years) and scored according to EU-TIRADS, using ultrasound examination. In all tumors, histopathological verification was performed. Results: In EU-TIRADS 2 (154 nodules) all nodules were benign; in EU-TIRADS 3, only 3/93 malignancies were identified. In EU-TIRADS 4, 12/103 were malignant, and in EU-TIRADS 5 (278 benign vs. 214 malignant). The malignant nodules that would not have qualified for biopsy were: EU-TIRADS 3, 2/3 (67%) malignancies were <20 mm, in EU-TIRADS 4, 7/12 (58%) were <15 mm. In EU-TIRADS 5, 72/214 (34%) were <10 mm; in total, 81/229 (36%) malignant lesions would have been missed. The cutoff between EU-TIRADS 3/4 had sensitivity of 100%, specificity of 25.1%. Using cutoff for EU-TIRADS 5, 93.4%, 54.6%, respectively. Conclusion: The application of EU-TIRADS guidelines allowed us to achieve moderate specificity. The vast majority of malignancies in EU-TIRADS 3, 4, and 5 would not have been recommended for biopsy because having a smaller size than that proposed classification.