Effect of Inhaler Design Variables on Paediatric Use of Dry Powder Inhalers
Open Access
- 5 June 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (6) , e99304
Abstract
Age appropriateness is a major concern of pulmonary delivery devices, in particular of dry powder inhalers (DPIs), since their performance strongly depends on the inspiratory flow manoeuvre of the patient. Previous research on the use of DPIs by children focused mostly on specific DPIs or single inspiratory parameters. In this study, we investigated the requirements for a paediatric DPI more broadly using an instrumented test inhaler. Our primary aim was to assess the impact of airflow resistance on children’s inspiratory flow profiles. Additionally, we investigated children’s preferences for airflow resistance and mouthpiece design and how these relate to what may be most suitable for them. We tested 98 children (aged 4.7–12.6 years), of whom 91 were able to perform one or more correct inhalations through the test inhaler. We recorded flow profiles at five airflow resistances ranging from 0.025 to 0.055 kPa0.5.min.L−1 and computed various inspiratory flow parameters from these recordings. A sinuscope was used to observe any obstructions in the oral cavity during inhalation. 256 flow profiles were included for analysis. We found that both airflow resistance and the children’s characteristics affect the inspiratory parameters. Our data suggest that a medium-high resistance is both suitable for and well appreciated by children aged 5–12 years. High incidences (up to 90%) of obstructions were found, which may restrict the use of DPIs by children. However, an oblong mouthpiece that was preferred the most appeared to positively affect the passageway through the oral cavity. To accommodate children from the age of 5 years onwards, a DPI should deliver a sufficiently high fine particle dose within an inhaled volume of 0.5 L and at a peak inspiratory flow rate of 25–40 L.min−1. We recommend taking these requirements into account for future paediatric inhaler development.Keywords
This publication has 25 references indexed in Scilit:
- What the pulmonary specialist should know about the new inhalation therapiesEuropean Respiratory Journal, 2011
- The ADMIT series — Issues in Inhalation Therapy. 5) Inhaler selection in children with asthmaPrimary Care Respiratory Journal, 2010
- Effect of Dry Powder Inhaler Resistance on the Inspiratory Flow Rates and Volumes of Cystic Fibrosis Patients of Six Years and OlderJournal of Aerosol Medicine, 2006
- Measurement of Inspiratory Flow Through Three Different Dry Powder Inhalation Devices Using In-Check TM in Children with AsthmaPediatric Asthma, Allergy & Immunology, 2006
- Ability of preschool children to use dry powder inhalers as evaluated by In‐Check MeterPediatrics International, 2006
- Determinants of correct inhalation technique in children attending a hospital‐based asthma clinicActa Paediatrica, 2002
- Clinical effect of Diskus dry-powder inhaler at low and high inspiratory flow-rates in asthmatic childrenEuropean Respiratory Journal, 1998
- Lung deposition from the Turbuhaler in children with cystic fibrosisEuropean Respiratory Journal, 1997
- Effect of powder inhaler design on drug deposition in the respiratory tractInternational Journal of Pharmaceutics, 1988
- How to use a rotahaler.Archives of Disease in Childhood, 1986