Predicting Risk of Endovascular Device Infection in Patients With Staphylococcus aureus Bacteremia (PREDICT-SAB)
Authors:
- M. Rizwan SohailMSM. Rizwan Sohail
- Bharath Raj PalrajBPBharath Raj Palraj
- Sana KhalidSKSana Khalid
- Daniel Z. UslanDUDaniel Z. Uslan
- Farah Al-SaffarFAFarah Al-Saffar
- Paul A. FriedmanPFPaul A. Friedman
- David L. HayesDHDavid L. Hayes
- Christine M. LohseCLChristine M. Lohse
- Walter R. WilsonWWWalter R. Wilson
- James M. SteckelbergJSJames M. Steckelberg
- Larry M. BaddourLBLarry M. Baddour
- 1 February 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (1) , 137-144
Abstract
Background—: Prompt recognition of underlying cardiovascular implantable electronic device (CIED) infection in patients presenting with Staphylococcus aureus bacteremia (SAB) is critical for optimal management of these cases. The goal of this study was to identify clinical predictors of CIED infection in patients presenting with SAB and no signs of pocket infection. Methods and Results—: All cases of SAB in CIED recipients at Mayo Clinic from 2001 to 2011 were retrospectively reviewed. We identified 131 patients with CIED who presented with SAB and had no clinical signs of device pocket infection. Forty-five (34%) of these patients had underlying CIED infection based on clinical or echocardiographic criteria. The presence of a permanent pacemaker rather than an implantable cardioverter-defibrillator (odds ratio, 3.90; 95% confidence interval, 1.65–9.23; P =0.002), >1 device-related procedure (odds ratio, 3.30; 95% confidence interval, 1.23–8.86; P =0.018), and duration of SAB ≥4 days (odds ratio, 5.54; 95% confidence interval, 3.32–13.23; P <0.001) were independently associated with an increased risk of CIED infection in a multivariable model. The area under the receiver operating characteristics curve for the multivariable model was 0.79, indicating a good discriminatory capacity to distinguish SAB patients with and without CIED infection. Conclusions—: Among patients presenting with SAB and no signs of pocket infection, the risk of underlying CIED infection can be calculated based on the type of device, number of device-related procedures, and duration of SAB. We propose that patients without any of these high-risk features have a low risk of underlying CIED infection and may be monitored closely without immediate device extraction. Prospective studies are needed to validate this risk prediction model.Keywords
This publication has 23 references indexed in Scilit:
- Timing of the Most Recent Device Procedure Influences the Clinical Outcome of Lead-Associated EndocarditisJACC, 2012
- Cardiovascular Implantable Electronic Device Infection in Patients withStaphylococcus aureusBacteremiaPacing and Clinical Electrophysiology, 2010
- Recurrent Implantable Cardioverter-Defibrillator Replacement Is Associated with an Increasing Risk of Pocket-Related ComplicationsPacing and Clinical Electrophysiology, 2010
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Risk factors and time delay associated with cardiac device infections: Leiden device registryHeart, 2008
- Lead‐Associated Endocarditis: The Important Role of Methicillin‐Resistant Staphylococcus aureusPacing and Clinical Electrophysiology, 2008
- Risk Factor Analysis of Permanent Pacemaker InfectionClinical Infectious Diseases, 2007
- Prospective study of 424 cases of Staphylococcus aureus bacteraemia: determination of factors affecting incidence and mortalityInternal Medicine Journal, 2001
- Sustained Bacteremia in 26 Patients with a Permanent Endocardial Pacemaker: Assessment of Wire RemovalClinical Infectious Diseases, 1993
- Optimal Duration of Therapy for Catheter-Related Staphylococcus aureus Bacteremia: A Study of 55 Cases and ReviewClinical Infectious Diseases, 1992