Background: Ambulatory ECG monitoring is typically achieved using portable devices with limited number of surface leads, autonomy, and length of recording. Smart garments with multiple conductive textile electrodes provide great promise to perform continuous and comfortable ECG monitoring.Methods: We evaluated the ECG signal quality measured on healthy subjects with a smart 12‐lead ECG acquisition T‐shirt or a 12‐lead Holter recording. ECG signals were recorded during 3 min with both techniques in three resting positions (supine, seated, standing) and while walking. Three readers independently assessed ECG patterns and evaluated the denoising of the isoelectric line, the distinction of p waves, R peaks and RR intervals, and the possible appreciation of cardiac rhythm in at least 3 leads.Results: Thirty healthy subjects (70% males, 29.5 ± 7.8 years) were enrolled in the study. For all three resting conditions, cardiac rhythm was appreciated in 100% of recordings with distinction of p waves, R peaks, and isoelectric line in >97% of recordings. Appreciation of cardiac rhythm was lower in the walking conditions with both techniques (53.3% vs. 46.7%, Holter vs. smart T‐shirt, p = .60) mainly due to difficulties to distinguish p waves. These results were consistent across both genders. All ECG parameters (heart rate, PR, QRS and QTC intervals) were comparable between both techniques. No skin irritation was seen with the textile electrodes.Conclusions: A smart T‐shirt with 13 textiles electrodes allows short‐duration 12‐lead ECG acquisition with quality levels comparable to Holter recordings. The novel device should now be evaluated for long‐term non‐invasive ECG monitoring.Keywords
This publication has 19 references indexed in Scilit:
- Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt studyCardiology Journal, 2018
- Yield of atrial fibrillation detection with Textile Wearable Holter from the acute phase of stroke: Pilot study of Crypto-AF registryInternational Journal of Cardiology, 2018
- Supraventricular tachycardia diagnosed by smartphone ECGBMJ Case Reports, 2017
- Remote electrocardiograph monitoring using a novel adhesive strip sensor: A pilot studyWorld Journal of Cardiology, 2016
- Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: A systematic review and meta-analysisEuropean Journal of Preventive Cardiology, 2015
- Wireless Smartphone ECG Enables Large‐Scale Screening in Diverse PopulationsJournal of Cardiovascular Electrophysiology, 2015
- Atrial Fibrillation in Patients with Cryptogenic StrokeNew England Journal of Medicine, 2014
- Twenty‐eight day Holter monitoring is poorly tolerated and insensitive for paroxysmal atrial fibrillation detection in cryptogenic strokeInternal Medicine Journal, 2014
- Prolonged Rhythm Monitoring for the Detection of Occult Paroxysmal Atrial Fibrillation in Ischemic Stroke of Unknown CauseCirculation, 2011
- Intelligent Biomedical Clothing for Personal Health and Disease Management: State of the Art and Future VisionTelemedicine and e-Health, 2003