Adaptive decorrelation compensation approach in digital-image-correlation-assisted phase-sensitive optical coherence tomography
- 10 December 2024
- journal article
- research article
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (24) , 7194-7197
Abstract
This work demonstrates that the phase-based decorrelation compensation method outperforms the amplitude-based approach in low signal-to-noise ratio (SNR) regions of phase-sensitive optical coherence tomography (PhS-OCT). Building on this finding, an adaptive decorrelation compensation approach for digital-image-correlation (DIC)-assisted PhS-OCT is introduced. This method utilizes the maximum correlation coefficient from amplitude maps to adaptively determine the need for secondary tracking of decorrelated displacement using the phase-based approach. It significantly improves decorrelation compensation quality while minimizing impacts on computational efficiency. A tensile testing experiment was conducted to validate the method, with results showing that the proposed adaptive compensation method enables previously unmeasurable low SNR regions to become measurable by adaptively retracking only 21.7% of the area.Keywords
Funding Information
- National Natural Science Foundation of China (62171140, 62273105, 62475048)
- Natural Science Foundation of Guangdong Province (2024A1515010230)
This publication has 12 references indexed in Scilit:
- Visualizing curing process inside polymersApplied Physics Letters, 2020
- Enhancing the dynamic range of phase-sensitive optical coherence elastography by overcoming speckle decorrelationOptics Letters, 2018
- Dual-channel phase-contrast spectral optical coherence tomography for simultaneously measuring axial and normal to B-scan off-axial displacementsOptics and Lasers in Engineering, 2017
- Optical coherence elastography for strain dynamics measurements in laser correction of cornea shapeJournal of Biophotonics, 2017
- The emergence of optical elastography in biomedicineNature Photonics, 2017
- Hybrid method of strain estimation in optical coherence elastography using combined sub-wavelength phase measurements and supra-pixel displacement trackingJournal of Biophotonics, 2015
- Optical coherence tomography today: speed, contrast, and multimodalityJournal of Biomedical Optics, 2014
- Mean intensity gradient: An effective global parameter for quality assessment of the speckle patterns used in digital image correlationOptics and Lasers in Engineering, 2010
- Simultaneous measurement of in-plane and out-of-plane displacement fields in scattering media using phase-contrast spectral optical coherence tomographyOptics Letters, 2009
- Optical Coherence TomographyScience, 1991