Simulating Distal Radius Fracture Strength Using Biomechanical Tests: A Modeling Study Examining the Influence of Boundary Conditions
- 1 November 2011
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 133 (11) , 114501
Abstract
Distal radius fracture strength has been quantified using in vitro biomechanical testing. These tests are frequently performed using one of two methods: (1) load is applied directly to the embedded isolated radius or (2) load is applied through the hand with the wrist joint intact. Fracture loads established using the isolated radius method are consistently 1.5 to 3 times greater than those for the intact wrist method. To address this discrepancy, a validated finite element modeling procedure was used to predict distal radius fracture strength for 22 female forearms under boundary conditions simulating the isolated radius and intact wrist method. Predicted fracture strength was highly correlated between methods (r = 0.94; p < 0.001); however, intact wrist simulations were characterized by significantly reduced cortical shell load carriage and increased stress and strain concentrations. These changes resulted in fracture strength values less than half those predicted for the isolated radius simulations (2274 ± 824 N for isolated radius, 1124 ± 375 N for intact wrist; p < 0.001). The isolated radius method underestimated the mechanical importance of the trabecular compartment compared to the more physiologically relevant intact wrist scenario. These differences should be borne in mind when interpreting the physiologic importance of mechanical testing and simulation results.Keywords
This publication has 27 references indexed in Scilit:
- Finite element prediction of surface strain and fracture strength at the distal radiusMedical Engineering & Physics, 2011
- Finite Element Modeling of the Influence of Hand Position and Bone Properties on the Colles’ Fracture Load During a FallJournal of Biomechanical Engineering, 2010
- On Colles’ Fracture: An Experimental Study Involving Structural and Material TestingJournal of Applied Mechanics, 2008
- Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: A finite element analysisJournal of Biomechanics, 2007
- Subject-specific finite element models can accurately predict strain levels in long bonesJournal of Biomechanics, 2007
- Bone Strength at Clinically Relevant Sites Displays Substantial Heterogeneity and Is Best Predicted From Site-Specific Bone DensitometryJournal of Bone and Mineral Research, 2002
- Prediction of bone strength of distal forearm using radius bone mineral density and phalangeal speed of soundBone, 2000
- Prediction of fracture load at different skeletal sites by geometric properties of the cortical shellJournal of Bone and Mineral Research, 1996
- Predicting the compressive mechanical behavior of boneJournal of Biomechanics, 1994
- Tensile and compressive properties of cancellous boneJournal of Biomechanics, 1991