  • Bone mineral loss at the proximal femur in acute spinal cord injury

    by W. B. Edwards, T. J. Schnitzer, K. L. Troy

    Summary This study used quantitative computed tomography to assess changes in bone mineral at the proximal femur after acute spinal cord injury (SCI). Individuals with acute SCI experienced a marked loss of bone mineral from a combination of trabecular and endocortical resorption. Targeted therapeutic interventions are thus warranted in this population. Introduction SCI is associated with a rapid loss of bone mineral and an increased rate of fragility fracture. Some 10 to 20 % of these fractures occur at the proximal femur. The purpose of this study was to quantify changes to bone mineral, geometry, and measures of strength at the proximal femur in acute SCI. Methods Quantitative computed tomography analysis was performed on 13 subjects with acute SCI at serial time points separated by a mean of 3.5 months (range, 2.6–4.8 months). Changes in bone mineral content (BMC) and volumetric bone mineral density (vBMD) were quantified for integral, trabecular, and cortical bone at the femoral neck, trochanteric, and total proximal femur regions. Changes in bone volumes, cross-sectional areas, and surrogate measures of compressive and bending strength were also determined. Results During the acute period of SCI, subjects experienced a 2.7–3.3 %/month reduction in integral BMC (p < 0.001) and a 2.5–3.1 %/month reduction in integral vBMD (p < 0.001). Trabecular BMC decreased by 3.1–4.7 %/month (p < 0.001) and trabecular vBMD by 2.8–4.4 %/month (p < 0.001). A 3.9–4.0 %/month reduction was observed for cortical BMC (p < 0.001), while the reduction in cortical vBMD was noticeably lower (0.8–1.0 %/month; p ≤ 0.01). Changes in bone volume and cross-sectional area suggested that cortical bone loss occurred primarily through endosteal resorption. Declines in bone mineral were associated with a 4.9–5.9 %/month reduction in surrogate measures of strength. Conclusions These data highlight the need for therapeutic interventions in this population that target both trabecular and endocortical bone mineral preservation.


  • A linear-actuated torsional device to replicate clinically relevant spiral fractures in long bones

    by W Brent Edwards, Karen L Troy

    To better understand the mechanisms underlying spiral fracture we would like to carry out biomechanical tests of long bones loaded in torsion to failure. A device was fabricated to perform torsional tests of long bones using a single-axis linear actuator. The principal operation of the device was to transform the vertical displacement of a material testing machine’s linear actuator into rotational movement using a spur gear and rack system. Accuracy and precision of the device were quantified using cast-acrylic rods with known torque–rotation behavior. Cadaveric experimentation was used to replicate a clinically relevant spiral fracture in eleven human proximal tibiae; strain-gage data were recorded for a single specimen. The device had an experimental error of less than 0.2 Nm and was repeatable to within 0.3%. Strain gage data were in line with those expected from pure torsion and the cadaveric tibiae illustrated spiral fractures at ultimate torque and rotation values of 130.6 ± 53.2 Nm and 8.3 ± 1.5°, respectively. Ultimate torque was highly correlated with DXA assessed bone mineral density (r = 0.87; p < 0.001). The device presented is applicable to any torsional testing of long bone when only a single-axis linear actuator is available.


  • Simulating Distal Radius Fracture Strength Using Biomechanical Tests: A Modeling Study Examining the Influence of Boundary Conditions

    by W. Brent Edwards, Karen L. Troy

    Distal radius fracture strength has been quantified using in vitro biomechanical testing. These tests are frequently performed using one of two methods: (1) load is applied directly to the embedded isolated radius or (2) load is applied through the hand with the wrist joint intact. Fracture loads established using the isolated radius method are consistently 1.5 to 3 times greater than those for the intact wrist method. To address this discrepancy, a validated finite element modeling procedure was used to predict distal radius fracture strength for 22 female forearms under boundary conditions simulating the isolated radius and intact wrist method. Predicted fracture strength was highly correlated between methods (r = 0.94; p < 0.001); however, intact wrist simulations were characterized by significantly reduced cortical shell load carriage and increased stress and strain concentrations. These changes resulted in fracture strength values less than half those predicted for the isolated radius simulations (2274 ± 824 N for isolated radius, 1124 ± 375 N for intact wrist; p < 0.001). The isolated radius method underestimated the mechanical importance of the trabecular compartment compared to the more physiologically relevant intact wrist scenario. These differences should be borne in mind when interpreting the physiologic importance of mechanical testing and simulation results.


  • Finite element prediction of surface strain and fracture strength at the distal radius

    by W. Brent Edwards, Karen L. Troy

    To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific finite element models to validate our model-generating algorithm. Five cadaveric forearms were instrumented with strain gage rosettes, loaded non-destructively to 300 N, and subsequently loaded until failure. Finite element models were created from computed tomography data; three separate density-elasticity relationships were examined. Fracture strength was predicted for three specimens that failed at the distal radius using six different failure theories. The density-elasticity relationship providing the strongest agreement between measured and predicted strains had a correlation of r=0.90 and a root mean squared error 13% of the highest measured strain. Mean absolute percent error (11.6%) between measured and predicted fracture loads was minimized with Coulomb-Mohr failure theory and a tensile-compressive strength ratio of 0.5. These results suggest that our modeling method is a suitable candidate for the in vivo assessment of distal radius bone strain and fracture strength under fall type loading configurations.


  • On the filtering of intersegmental loads during running

    by W. Brent Edwards, Karen L. Troy, Timothy R. Derrick


  • Effects of running speed on a probabilistic stress fracture model

    by W. Brent Edwards, David Taylor, Thomas J. Rudolphi, Jason C. Gillette, Timothy R. Derrick