Assessment of inflow and washout of indocyanine green in the adult human brain by monitoring of diffuse reflectance at large source-detector separation
- 1 January 2011
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (4) , 046011-046011-7
Abstract
Recently, it was shown in measurements carried out on humans that time-resolved near-infrared reflectometry and fluorescence spectroscopy may allow for discrimination of information originating directly from the brain avoiding influence of contaminating signals related to the perfusion of extracerebral tissues. We report on continuation of these studies, showing that the near-infrared light can be detected noninvasively on the surface of the tissue at large interoptode distance. A multichannel time-resolved optical monitoring system was constructed for measurements of diffuse reflectance in optically turbid medium at very large source-detector separation up to 9 cm. The instrument was applied during intravenous injection of indocyanine green and the distributions of times of flight of photons were successfully acquired showing inflow and washout of the dye in the tissue. Time courses of the statistical moments of distributions of times of flight of photons are presented and compared to the results obtained simultaneously at shorter source-detector separations (3, 4, and 5 cm). We show in a series of experiments carried out on physical phantom and healthy volunteers that the time-resolved data acquisition in combination with very large source-detector separation may allow one to improve depth selectivity of perfusion assessment in the brain.Keywords
Funding Information
- European Community’s Seventh Framework Programme (201076)
- European Community's Seventh Framework Programme (201076)
- EC Seventh Framework Programme (201076)
This publication has 42 references indexed in Scilit:
- Optical system based on time-gated, intensified charge-coupled device camera for brain imaging studiesJournal of Biomedical Optics, 2010
- Optical bedside monitoring of cerebral perfusion: technological and methodological advances applied in a study on acute ischemic strokeJournal of Biomedical Optics, 2010
- Time-resolved imaging of fluorescent inclusions in optically turbid medium — phantom studyOpto-Electronics Review, 2010
- A Comparative Study of Brain Perfusion Single-Photon Emission Computed Tomography and Magnetic Resonance Imaging in Patients with Post-traumatic AnosmiaAmerican Journal of Rhinology & Allergy, 2009
- Towards Noninvasive Molecular Fluorescence Imaging of the Human BrainNeurodegenerative Diseases, 2008
- Multichannel Time-Resolved Tissue Oximeter for Functional Imaging of the BrainIEEE Transactions on Instrumentation and Measurement, 2006
- Cerebral Perfusion ImagingJournal of Neuro-Ophthalmology, 2005
- Comparative Overview of Brain Perfusion Imaging TechniquesStroke, 2005
- Fiber dispersion in time domain measurements compromising the accuracy of determination of optical properties of strongly scattering mediaJournal of Biomedical Optics, 2003
- Non-invasive optical spectroscopy and imaging of human brain functionTrends in Neurosciences, 1997