Toward noninvasive estimation of nonlinear tumor stiffness from B-mode ultrasound under compression: an in silico feasibility study
Open Access
- 2 November 2026
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215012
Abstract
Objective. Tumor stiffness has shown promise as a biomechanical marker of malignancy. However, many elastography studies model tumors as linear elastic materials, which may not fully capture the nonlinear behavior of soft tissue. This study developed and evaluated an inverse finite-element (FE) framework for estimating nonlinear tumor stiffness from standard B-mode ultrasound (US) images acquired during controlled compression. Approach. Synthetic B-mode images were generated from FE simulations of elliptical tumors embedded in healthy tissue. Three tumor aspect ratios were considered: α = 0.35 , 0.50 , and 0.75 . Both the tumor and surrounding tissue were modeled as nearly incompressible neo-Hookean materials. Tumor stiffness was assigned as 2 × , 4 × , or 6 × the background tissue stiffness, and three levels of compression were applied. Speckle tracking was used to estimate tissue displacements between the undeformed and compressed images. These displacement fields were then used in an inverse FE optimization. Two formulations were tested: one in which the background tissue stiffness was known and another in which both tumor and background stiffness were estimated. Main results. The inverse model closely reproduced the speckle-tracking (ST) displacement fields, with mean absolute errors below 0.01 mm for all cases. When the background tissue stiffness was known, tumor stiffness was estimated with R 2 > 0.98 . The average prediction errors were 2.57%, 2.90%, and 4.04% for α = 0.35 , 0.50 , and 0.75 , respectively, with a maximum error of 6.87%. However, estimating both stiffness parameters reduced accuracy because different tumor and tissue stiffness combinations could produce similar displacement patterns. Significance. These results demonstrate the feasibility of estimating nonlinear tumor stiffness from B-mode US-derived displacement fields using ST and inverse modeling in a controlled in silico setting. The study provides a computational framework for tumor stiffness estimation, with further methodological development needed to address segmentation, loading, and boundary-condition uncertainties before extending the approach beyond the controlled in silico setting.Keywords
This publication has 51 references indexed in Scilit:
- Optimal design for multi-compartment cell elasticity estimation using AFM and super-resolution imagingComputer Methods and Programs in Biomedicine, 2026
- In-silico heart model phantom to validate cardiac strain imagingComputers in Biology and Medicine, 2024
- Ejection Fraction Pros and ConsJACC, 2018
- An integrated inverse model-experimental approach to determine soft tissue three-dimensional constitutive parameters: application to post-infarcted myocardiumBiomechanics and Modeling in Mechanobiology, 2017
- Stiffness of benign and malignant prostate tissue measured by shear-wave elastography: a preliminary studyEuropean Radiology, 2016
- Substrate stiffness modulates lung cancer cell migration but not epithelial to mesenchymal transitionJournal of Biomedical Materials Research Part A, 2016
- Hallmarks of Cancer: The Next GenerationCell, 2011
- Biomechanical Forces Shape the Tumor MicroenvironmentAnnals of Biomedical Engineering, 2011
- Matrix Crosslinking Forces Tumor Progression by Enhancing Integrin SignalingCell, 2009
- AFM indentation study of breast cancer cellsBiochemical and Biophysical Research Communications, 2008