Tanmay Mukherjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tanmay Mukherjee has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Reza Avazmohammadi
Texas A&M University
8 shared publications Amr Darwish
Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, 77030, USA
3 shared publicationsDiana Lindquist
Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH 45229, USA
3 shared publicationsDipan J. Shah
Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, 77030, USA
3 shared publicationsEmilio A. Mendiola
Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
3 shared publicationsJacques Ohayon
Savoie Mont-Blanc University, Polytech Annecy-Chambéry, Le Bourget du Lac, France; Laboratory TIMC-CNRS, UMR 5525, Grenoble-Alpes University, Grenoble, France
3 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215012
Toward noninvasive estimation of nonlinear tumor stiffness from B-mode ultrasound under compression: an in silico feasibility study
Objective. Tumor stiffness has shown promise as a biomechanical marker of malignancy. However, many elastography studies model tumors as linear elastic materials, which may not fully capture the nonlinear behavior of soft tissue. This study developed and evaluated an inverse finite-element (FE) framework for estimating nonlinear tumor stiffness from standard B-mode ultrasound (US) images acquired during controlled compression. Approach. Synthetic B-mode images were generated from FE simulations of elliptical tumors embedded in healthy tissue. Three tumor aspect ratios were considered: α = 0.35 , 0.50 , and 0.75 . Both the tumor and surrounding tissue were modeled as nearly incompressible neo-Hookean materials. Tumor stiffness was assigned as 2 × , 4 × , or 6 × the background tissue stiffness, and three levels of compression were applied. Speckle tracking was used to estimate tissue displacements between the undeformed and compressed images. These displacement fields were then used in an inverse FE optimization. Two formulations were tested: one in which the background tissue stiffness was known and another in which both tumor and background stiffness were estimated. Main results. The inverse model closely reproduced the speckle-tracking (ST) displacement fields, with mean absolute errors below 0.01 mm for all cases. When the background tissue stiffness was known, tumor stiffness was estimated with R 2 > 0.98 . The average prediction errors were 2.57%, 2.90%, and 4.04% for α = 0.35 , 0.50 , and 0.75 , respectively, with a maximum error of 6.87%. However, estimating both stiffness parameters reduced accuracy because different tumor and tissue stiffness combinations could produce similar displacement patterns. Significance. These results demonstrate the feasibility of estimating nonlinear tumor stiffness from B-mode US-derived displacement fields using ST and inverse modeling in a controlled in silico setting. The study provides a computational framework for tumor stiffness estimation, with further methodological development needed to address segmentation, loading, and boundary-condition uncertainties before extending the approach beyond the controlled in silico setting.
- 2 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215012
Open AccessToward noninvasive estimation of nonlinear tumor stiffness from B-mode ultrasound under compression: an in silico feasibility study
Objective. Tumor stiffness has shown promise as a biomechanical marker of malignancy. However, many elastography studies model tumors as linear elastic materials, which may not fully capture the nonlinear behavior of soft tissue. This study developed and evaluated an inverse finite-element (FE) framework for estimating nonlinear tumor stiffness from standard B-mode ultrasound (US) images acquired during controlled compression. Approach. Synthetic B-mode images were generated from FE simulations of elliptical tumors embedded in healthy tissue. Three tumor aspect ratios were considered: α = 0.35 , 0.50 , and 0.75 . Both the tumor and surrounding tissue were modeled as nearly incompressible neo-Hookean materials. Tumor stiffness was assigned as 2 × , 4 × , or 6 × the background tissue stiffness, and three levels of compression were applied. Speckle tracking was used to estimate tissue displacements between the undeformed and compressed images. These displacement fields were then used in an inverse FE optimization. Two formulations were tested: one in which the background tissue stiffness was known and another in which both tumor and background stiffness were estimated. Main results. The inverse model closely reproduced the speckle-tracking (ST) displacement fields, with mean absolute errors below 0.01 mm for all cases. When the background tissue stiffness was known, tumor stiffness was estimated with R 2 > 0.98 . The average prediction errors were 2.57%, 2.90%, and 4.04% for α = 0.35 , 0.50 , and 0.75 , respectively, with a maximum error of 6.87%. However, estimating both stiffness parameters reduced accuracy because different tumor and tissue stiffness combinations could produce similar displacement patterns. Significance. These results demonstrate the feasibility of estimating nonlinear tumor stiffness from B-mode US-derived displacement fields using ST and inverse modeling in a controlled in silico setting. The study provides a computational framework for tumor stiffness estimation, with further methodological development needed to address segmentation, loading, and boundary-condition uncertainties before extending the approach beyond the controlled in silico setting.
- Open Access
- 23 March 2026
- Published by Elsevier in International Journal of Engineering Science
- Vol. 224
Computational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion
- 23 March 2026
- Published by Elsevier in International Journal of Engineering Science
- Vol. 224
Open AccessComputational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion
- Open Access
- 15 February 2026
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (17) , e03034
Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling
Cardiovascular diseases (CVDs) remain the leading cause of death worldwide, underscoring the need for improved strategies in diagnosis, treatment, and disease modeling. Traditional in vitro models often fall short in replicating human CV physiology, prompting efforts to advance cardiac tissue engineering and computational modeling. Among these, three‐dimensional (3D) bioprinting has emerged as a transformative tool, enabling the creation of biomimetic CV constructs that more faithfully replicate native tissue structure and function. However, challenges persist in achieving appropriate mechanical properties and long‐term performance of engineered CV constructs. Computational modeling offers powerful solutions to assist with these challenges, providing predictive insights into structural remodeling, hemodynamics, disease progression, and therapeutic response. Techniques such as computational fluid dynamics and machine learning are increasingly used to optimize design and simulate physiological conditions. The integration of computational models with 3D bioprinting has led to hybrid platforms that enhance the precision and utility of engineered tissues. This review highlights recent advances in computational modeling applied to 3D bioprinted CV constructs, focusing on the added benefits of integrating these technologies to achieve a more accurate modeling of complex CV conditions. Together, these technologies offer a promising path toward clinically translatable, patient‐specific CV platforms.
- 15 February 2026
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (17) , e03034
Open AccessComputational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling
Cardiovascular diseases (CVDs) remain the leading cause of death worldwide, underscoring the need for improved strategies in diagnosis, treatment, and disease modeling. Traditional in vitro models often fall short in replicating human CV physiology, prompting efforts to advance cardiac tissue engineering and computational modeling. Among these, three‐dimensional (3D) bioprinting has emerged as a transformative tool, enabling the creation of biomimetic CV constructs that more faithfully replicate native tissue structure and function. However, challenges persist in achieving appropriate mechanical properties and long‐term performance of engineered CV constructs. Computational modeling offers powerful solutions to assist with these challenges, providing predictive insights into structural remodeling, hemodynamics, disease progression, and therapeutic response. Techniques such as computational fluid dynamics and machine learning are increasingly used to optimize design and simulate physiological conditions. The integration of computational models with 3D bioprinting has led to hybrid platforms that enhance the precision and utility of engineered tissues. This review highlights recent advances in computational modeling applied to 3D bioprinted CV constructs, focusing on the added benefits of integrating these technologies to achieve a more accurate modeling of complex CV conditions. Together, these technologies offer a promising path toward clinically translatable, patient‐specific CV platforms.
- Open Access
- 6 February 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
A narrative review of computational approaches to understand type B aortic dissection mechanisms and predictions
- 6 February 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Open AccessA narrative review of computational approaches to understand type B aortic dissection mechanisms and predictions
- 31 August 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 181, 109065
In-silico heart model phantom to validate cardiac strain imaging
- 31 August 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 181, 109065
In-silico heart model phantom to validate cardiac strain imaging
- Open Access
Computational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion
Intracardiac hemodynamics plays a crucial role in the onset and development of cardiac and valvular diseases. Simulations of blood flow in the left ventricle (LV) have provided valuable insight into assessing LV hemodynamics. While fully coupled fluid-solid modelings of the LV remain challenging due to the complex passive-active behavior of the LV wall myocardium, the integration of imaging-driven quantification of structural motion with computational fluid dynamics (CFD) modeling in the LV holds the promise of feasible and clinically translatable characterization of patient-specific LV hemodynamics. In this study, we propose to integrate two magnetic resonance imaging (MRI) modalities with the moving-boundary CFD method to characterize intracardiac LV hemodynamics. Our method uses the standard cine cardiac magnetic resonance (CMR) images to estimate four-dimensional myocardial motion, eliminating the need for involved myocardial material modeling to capture LV wall behavior. In conjunction with CMR, phase contrast-MRI (PC-MRI) was used to measure temporal blood inflow rates at the mitral orifice, serving as an additional boundary condition. Flow patterns, including velocity streamlines, vortex rings, and kinetic energy, were characterized and compared to the available data. Moreover, relationships between LV wall kinematic markers and flow characteristics were determined without myocardial material modeling and using a non-rigid image registration (NRIR) method. The fidelity of the simulation was quantitatively evaluated by validating the flow rate at the aortic outflow tract against respective PC-MRI measures. The proposed methodology offers a novel and feasible toolset that works with standard PC-CMR protocols to improve the clinical assessment of LV characteristics in prognostic studies and surgical planning.
Open AccessComputational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion
Intracardiac hemodynamics plays a crucial role in the onset and development of cardiac and valvular diseases. Simulations of blood flow in the left ventricle (LV) have provided valuable insight into assessing LV hemodynamics. While fully coupled fluid-solid modelings of the LV remain challenging due to the complex passive-active behavior of the LV wall myocardium, the integration of imaging-driven quantification of structural motion with computational fluid dynamics (CFD) modeling in the LV holds the promise of feasible and clinically translatable characterization of patient-specific LV hemodynamics. In this study, we propose to integrate two magnetic resonance imaging (MRI) modalities with the moving-boundary CFD method to characterize intracardiac LV hemodynamics. Our method uses the standard cine cardiac magnetic resonance (CMR) images to estimate four-dimensional myocardial motion, eliminating the need for involved myocardial material modeling to capture LV wall behavior. In conjunction with CMR, phase contrast-MRI (PC-MRI) was used to measure temporal blood inflow rates at the mitral orifice, serving as an additional boundary condition. Flow patterns, including velocity streamlines, vortex rings, and kinetic energy, were characterized and compared to the available data. Moreover, relationships between LV wall kinematic markers and flow characteristics were determined without myocardial material modeling and using a non-rigid image registration (NRIR) method. The fidelity of the simulation was quantitatively evaluated by validating the flow rate at the aortic outflow tract against respective PC-MRI measures. The proposed methodology offers a novel and feasible toolset that works with standard PC-CMR protocols to improve the clinical assessment of LV characteristics in prognostic studies and surgical planning.
- Open Access
In-silico heart model phantom to validate cardiac strain imaging
The quantification of cardiac strains as structural indices of cardiac function has a growing prevalence in clinical diagnosis. However, the highly heterogeneous four-dimensional (4D) cardiac motion challenges accurate “regional” strain quantification and leads to sizable differences in the estimated strains depending on the imaging modality and post-processing algorithm, limiting the translational potential of strains as incremental biomarkers of cardiac dysfunction. There remains a crucial need for a feasible benchmark that successfully replicates complex 4D cardiac kinematics to determine the reliability of strain calculation algorithms. In this study, we propose an in-silico heart phantom derived from finite element (FE) simulations to validate the quantification of 4D regional strains. First, as a proof-of-concept exercise, we created synthetic magnetic resonance (MR) images for a hollow thick-walled cylinder under pure torsion with an exact solution and demonstrated that “ground-truth” values can be recovered for the twist angle, which is also a key kinematic index in the heart. Next, we used mouse-specific FE simulations of cardiac kinematics to synthesize dynamic MR images by sampling various sectional planes of the left ventricle (LV). Strains were calculated using our recently developed non-rigid image registration (NRIR) framework in both problems. Moreover, we studied the effects of image quality on distorting regional strain calculations by conducting in-silico experiments for various LV configurations. Our studies offer a rigorous and feasible tool to standardize regional strain calculations to improve their clinical impact as incremental biomarkers.
Open AccessIn-silico heart model phantom to validate cardiac strain imaging
The quantification of cardiac strains as structural indices of cardiac function has a growing prevalence in clinical diagnosis. However, the highly heterogeneous four-dimensional (4D) cardiac motion challenges accurate “regional” strain quantification and leads to sizable differences in the estimated strains depending on the imaging modality and post-processing algorithm, limiting the translational potential of strains as incremental biomarkers of cardiac dysfunction. There remains a crucial need for a feasible benchmark that successfully replicates complex 4D cardiac kinematics to determine the reliability of strain calculation algorithms. In this study, we propose an in-silico heart phantom derived from finite element (FE) simulations to validate the quantification of 4D regional strains. First, as a proof-of-concept exercise, we created synthetic magnetic resonance (MR) images for a hollow thick-walled cylinder under pure torsion with an exact solution and demonstrated that “ground-truth” values can be recovered for the twist angle, which is also a key kinematic index in the heart. Next, we used mouse-specific FE simulations of cardiac kinematics to synthesize dynamic MR images by sampling various sectional planes of the left ventricle (LV). Strains were calculated using our recently developed non-rigid image registration (NRIR) framework in both problems. Moreover, we studied the effects of image quality on distorting regional strain calculations by conducting in-silico experiments for various LV configurations. Our studies offer a rigorous and feasible tool to standardize regional strain calculations to improve their clinical impact as incremental biomarkers.
- Open Access
Complete spatiotemporal quantification of cardiac motion in mice through enhanced acquisition and super-resolution reconstruction
The quantification of cardiac motion using cardiac magnetic resonance imaging (CMR) has shown promise as an early-stage marker for cardiovascular diseases. Despite the growing popularity of CMR-based myocardial strain calculations, measures of complete spatiotemporal strains (i.e., three-dimensional strains over the cardiac cycle) remain elusive. Complete spatiotemporal strain calculations are primarily hampered by poor spatial resolution, with the rapid motion of the cardiac wall also challenging the reproducibility of such strains. We hypothesize that a super-resolution reconstruction (SRR) framework that leverages combined image acquisitions at multiple orientations will enhance the reproducibility of complete spatiotemporal strain estimation. Two sets of CMR acquisitions were obtained for five wild-type mice, combining short-axis scans with radial and orthogonal long-axis scans. Super-resolution reconstruction, integrated with tissue classification, was performed to generate full four-dimensional (4D) images. The resulting enhanced and full 4D images enabled complete quantification of the motion in terms of 4D myocardial strains. Additionally, the effects of SRR in improving accurate strain measurements were evaluated using an in-silico heart phantom. The SRR framework revealed near isotropic spatial resolution, high structural similarity, and minimal loss of contrast, which led to overall improvements in strain accuracy. In essence, a comprehensive methodology was generated to quantify complete and reproducible myocardial deformation, aiding in the much-needed standardization of complete spatiotemporal strain calculations.
Open AccessComplete spatiotemporal quantification of cardiac motion in mice through enhanced acquisition and super-resolution reconstruction
The quantification of cardiac motion using cardiac magnetic resonance imaging (CMR) has shown promise as an early-stage marker for cardiovascular diseases. Despite the growing popularity of CMR-based myocardial strain calculations, measures of complete spatiotemporal strains (i.e., three-dimensional strains over the cardiac cycle) remain elusive. Complete spatiotemporal strain calculations are primarily hampered by poor spatial resolution, with the rapid motion of the cardiac wall also challenging the reproducibility of such strains. We hypothesize that a super-resolution reconstruction (SRR) framework that leverages combined image acquisitions at multiple orientations will enhance the reproducibility of complete spatiotemporal strain estimation. Two sets of CMR acquisitions were obtained for five wild-type mice, combining short-axis scans with radial and orthogonal long-axis scans. Super-resolution reconstruction, integrated with tissue classification, was performed to generate full four-dimensional (4D) images. The resulting enhanced and full 4D images enabled complete quantification of the motion in terms of 4D myocardial strains. Additionally, the effects of SRR in improving accurate strain measurements were evaluated using an in-silico heart phantom. The SRR framework revealed near isotropic spatial resolution, high structural similarity, and minimal loss of contrast, which led to overall improvements in strain accuracy. In essence, a comprehensive methodology was generated to quantify complete and reproducible myocardial deformation, aiding in the much-needed standardization of complete spatiotemporal strain calculations.