Extramedullar fixation of 107 subtrochanteric fractures: A randomized multicenter trial of the Medoff sliding plate versus 3 other screw-plate systems
Authors:
- Leif CederLCLeif Ceder
- Jan TidermarkJTJan Tidermark
- Per HambergPHPer Hamberg
- Bengt-Erik LarssonBLBengt-Erik Larsson
- Björn RagnarssonBRBjörn Ragnarsson
- Richard W C KnebelRKRichard W C Knebel
- Ingemar AllvinIAIngemar Allvin
- Krister HjalmarsKHKrister Hjalmars
- Sigge NorbergSNSigge Norberg
- Per FornanderPFPer Fornander
- Anders HauggaardAHAnders Hauggaard
- 1 January 1999
- journal article
- clinical trial
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 70 (5) , 459-466
Abstract
We compared the efficacy of a load-sharing device, the Medoff sliding plate (MSP), with that of 3 other load-bearing screw-plate devices for the fixation of subtrochanteric fractures in a randomized multicenter trial of 107 elderly patients. 55 fractures were operated on with the MSP, and 52 with the dynamic hip screw (DHS) with or without a trochanteric stabilizing plate (TSP) or with the dynamic condylar screw (DCS). The patient material in the groups was similar regarding age, domestic situation, preinjury walking ability and fracture types. We followed the patients clinically and radiographically for a minimum of 1 year. There was no significant difference in walking ability or return rate to the home at follow-up. Fixation failure occurred in 1/55 fractures operated on with the MSP, in 3/32 with the DHS, in 3/12 with the DCS and in 2/8 with the DHS/TSR The difference in the rate of fixation failure was statistically significant, when the MSP group was compared to the 3 load-bearing devices in the other group (1 vs 8). On the basis of this experience, we think that the load-sharing principle of the MSP, which seems to facilitate fracture impaction and stability, appears to be a good alternative in extramedullary fixation of subtrochanteric fractures.Keywords
This publication has 15 references indexed in Scilit:
- Different Ways to Treat Subtrochanteric Fractures With the Medoff Sliding PlateClinical Orthopaedics and Related Research, 1998
- The Medoff sliding plate and a standard sliding hip screw for unstable intertrochanteric fractures: A mechanical comparison in cadaver femursActa Orthopaedica, 1998
- Intramedullary versus extramedullar fixation of subtrochanteric fractures: A biomechanical studyActa Orthopaedica, 1998
- Trochanteric hip fractures Fixation failure commoner with femoral medialization, a comparison of 101 casesActa Orthopaedica, 1996
- LOW-ENERGY SUBTROCHANTERIC FRACTURES IN ELDERLY PATIENTS1993
- Operative Stabilization of Subtrochanteric Fractures of the FemurJournal of Orthopaedic Trauma, 1990
- Subtrochanteric FracturesClinical Orthopaedics and Related Research, 1990
- Treatment of Subtrochanteric Femur Fractures Using the Dynamic Condylar ScrewJournal of Orthopaedic Trauma, 1989
- Treatment of Subtrochanteric Fractures with a Sliding Screw-plate Device1986
- Subtrochanteric Fractures of the Femur1979