Standardized 2D Ultrasound Sequences for Fetal Cardiac Screening: A Platform for AI Integration
Authors:
- Agnieszka NocunANAgnieszka Nocun
- Arkadiusz LewickiALArkadiusz Lewicki
- Magdalena DudzikMDMagdalena Dudzik
- Jerzy WegrzynowskiJWJerzy Wegrzynowski
- Malwina MertaMMMalwina Merta
- Piotr BralewskiPBPiotr Bralewski
- Krzysztof SerafinKSKrzysztof Serafin
- Alicja ZacharaAZAlicja Zachara
- Azer FarajovAFAzer Farajov
- Marcin WiechecMWMarcin Wiechec
- 24 March 2026
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 43 (3) , e70422
Abstract
Objective: The precise and consistent identification of fetal cardiac structures and functional flows is essential for the early diagnosis of congenital heart defects (CHDs), yet interobserver variability remains a significant challenge in clinical practice. Although fetal cardiac magnetic resonance imaging (MRI) has emerged as a valuable adjunct in selected cases, its routine use remains limited by long acquisition times, motion artifacts, and restricted availability in many centers. This underscores the need to optimize ultrasound‐based techniques that can reduce reliance on MRI while still providing comprehensive and reproducible fetal cardiac assessment. This article presents a study investigating the reliability of a layered imaging approach combined with standardized B‐mode and color Doppler ultrasound protocols to improve interobserver agreement in image interpretation among experts in fetal echocardiography. Methods: A dataset comprising 209 B‐mode and 205 color Doppler recordings acquired during midgestational anomaly scans (mean gestational age: 21.2 weeks) was systematically evaluated by five expert supervisors. Interobserver agreement was quantified using the prevalence‐adjusted bias‐adjusted kappa (PABAK) coefficient. To evaluate consistency across anatomical layers, one‐way ANOVA was employed, followed by post hoc analysis where applicable. Results: Most anatomical structures and functional features were consistently identified across observers, certain structures posed challenges, likely owing to their smaller size, lower visibility, or greater variability in presentation. Conclusion: By integrating structured imaging sequences with advanced statistical methodologies, this study explored the potential of improving diagnostic accuracy and standardization in fetal cardiac assessments, offering insights into the development of more reliable protocols for clinical applications and future research.Keywords
This publication has 14 references indexed in Scilit:
- Bio inspired technological performance in color Doppler ultrasonography and echocardiography for enhanced diagnostic precision in fetal congenital heart diseaseSLAS Technology, 2024
- Advances in the Application of Artificial Intelligence in Fetal EchocardiographyJournal of the American Society of Echocardiography, 2024
- ISUOG Practice Guidelines (updated): fetal cardiac screeningUltrasound in Obstetrics & Gynecology, 2023
- Guidelines and Recommendations for Performance of the Fetal Echocardiogram: An Update from the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2023
- Short‐term outcome after the prenatal diagnosis of right aortic archPrenatal Diagnosis, 2023
- AIUM Practice Parameter for the Performance of Fetal EchocardiographyJournal of Ultrasound in Medicine, 2019
- A brief history of fetal echocardiography and its impact on the management of congenital heart diseaseEchocardiography, 2017
- Optimal visualization of the fetal four‐chamber and outflow tract views with transabdominal ultrasound in the morbidly obese: Are we there yet?Journal of Clinical Ultrasound, 2015
- Barriers to prenatal detection of congenital heart disease: a population‐based studyUltrasound in Obstetrics & Gynecology, 2012
- Online evaluation of fetal second‐trimester four‐chamber view images: a comparison of six evaluation methodsUltrasound in Obstetrics & Gynecology, 2011