Krzysztof Serafin
Krzysztof Serafin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Agnieszka Nocun
MWU DOBREUSG Centre Of Ultrasound Diagnostics Krakow Poland
2 shared publications - Marcin Wiecheć
MWU DOBREUSG Centre Of Ultrasound Diagnostics Krakow Poland
2 shared publications - Agata P. Bochenska1 shared publication
Agnieszka A. Nocun
Ultrasound Laboratory MWU DOBRE USG Center of Ultrasound Diagnostics Cracow Poland
1 shared publication- Alicja Zachara
Collegium Medicum, Jan Kochanowski University in Kielce Kielce Poland
1 shared publication - Arkadiusz Lewicki
Faculty of Applied Computer Science, University of Information Technology and Management in Rzeszow
1 shared publication
Latest Publications
- 24 March 2026
- Published by Wiley in Echocardiography
- Vol. 43 (3) , e70422
Standardized 2D Ultrasound Sequences for Fetal Cardiac Screening: A Platform for AI Integration
Objective: The precise and consistent identification of fetal cardiac structures and functional flows is essential for the early diagnosis of congenital heart defects (CHDs), yet interobserver variability remains a significant challenge in clinical practice. Although fetal cardiac magnetic resonance imaging (MRI) has emerged as a valuable adjunct in selected cases, its routine use remains limited by long acquisition times, motion artifacts, and restricted availability in many centers. This underscores the need to optimize ultrasound‐based techniques that can reduce reliance on MRI while still providing comprehensive and reproducible fetal cardiac assessment. This article presents a study investigating the reliability of a layered imaging approach combined with standardized B‐mode and color Doppler ultrasound protocols to improve interobserver agreement in image interpretation among experts in fetal echocardiography. Methods: A dataset comprising 209 B‐mode and 205 color Doppler recordings acquired during midgestational anomaly scans (mean gestational age: 21.2 weeks) was systematically evaluated by five expert supervisors. Interobserver agreement was quantified using the prevalence‐adjusted bias‐adjusted kappa (PABAK) coefficient. To evaluate consistency across anatomical layers, one‐way ANOVA was employed, followed by post hoc analysis where applicable. Results: Most anatomical structures and functional features were consistently identified across observers, certain structures posed challenges, likely owing to their smaller size, lower visibility, or greater variability in presentation. Conclusion: By integrating structured imaging sequences with advanced statistical methodologies, this study explored the potential of improving diagnostic accuracy and standardization in fetal cardiac assessments, offering insights into the development of more reliable protocols for clinical applications and future research.
- 24 March 2026
- Published by Wiley in Echocardiography
- Vol. 43 (3) , e70422
Standardized 2D Ultrasound Sequences for Fetal Cardiac Screening: A Platform for AI Integration
Objective: The precise and consistent identification of fetal cardiac structures and functional flows is essential for the early diagnosis of congenital heart defects (CHDs), yet interobserver variability remains a significant challenge in clinical practice. Although fetal cardiac magnetic resonance imaging (MRI) has emerged as a valuable adjunct in selected cases, its routine use remains limited by long acquisition times, motion artifacts, and restricted availability in many centers. This underscores the need to optimize ultrasound‐based techniques that can reduce reliance on MRI while still providing comprehensive and reproducible fetal cardiac assessment. This article presents a study investigating the reliability of a layered imaging approach combined with standardized B‐mode and color Doppler ultrasound protocols to improve interobserver agreement in image interpretation among experts in fetal echocardiography. Methods: A dataset comprising 209 B‐mode and 205 color Doppler recordings acquired during midgestational anomaly scans (mean gestational age: 21.2 weeks) was systematically evaluated by five expert supervisors. Interobserver agreement was quantified using the prevalence‐adjusted bias‐adjusted kappa (PABAK) coefficient. To evaluate consistency across anatomical layers, one‐way ANOVA was employed, followed by post hoc analysis where applicable. Results: Most anatomical structures and functional features were consistently identified across observers, certain structures posed challenges, likely owing to their smaller size, lower visibility, or greater variability in presentation. Conclusion: By integrating structured imaging sequences with advanced statistical methodologies, this study explored the potential of improving diagnostic accuracy and standardization in fetal cardiac assessments, offering insights into the development of more reliable protocols for clinical applications and future research.
- Open Access
- 1 April 2025
- Published by AME Publishing Company in Cardiovascular Diagnosis and Therapy
- Vol. 15 (2) , 509-521
Aneurysm of the fetal right ventricular free wall progressing to hypoplastic right heart syndrome: prenatal diagnosis, maternal digoxin therapy, and successful surgical intervention—a case report
Video 1 Gestational age of 13 weeks + 0 days, image obtained using color Doppler. Video 2 Gestational age of 21 weeks + 2 days. Video 3 Gestational age of 27 weeks + 0 days, 4CV, video obtained using fetalHQ® software. Authors: Krzysztof Serafin, Agnieszka A. Nocun, Jacek Kolcz, Agata P. Bochenska, Emilia Gasiorowska, Marcin T. Wiechec
- 1 April 2025
- Published by AME Publishing Company in Cardiovascular Diagnosis and Therapy
- Vol. 15 (2) , 509-521
Open AccessAneurysm of the fetal right ventricular free wall progressing to hypoplastic right heart syndrome: prenatal diagnosis, maternal digoxin therapy, and successful surgical intervention—a case report
Video 1 Gestational age of 13 weeks + 0 days, image obtained using color Doppler. Video 2 Gestational age of 21 weeks + 2 days. Video 3 Gestational age of 27 weeks + 0 days, 4CV, video obtained using fetalHQ® software. Authors: Krzysztof Serafin, Agnieszka A. Nocun, Jacek Kolcz, Agata P. Bochenska, Emilia Gasiorowska, Marcin T. Wiechec
- 3 April 2024
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 43 (7) , 1319-1331
Comparison of Left Ventricular Stroke Volume in 2nd‐ and 3rd‐Trimester Fetuses Measured by the Product of VTI and Aortic Annular Area With That Assessed by Simpson's Single‐Plane Rule Using the STE Technique
Objectives: The aim of the study was to compare left ventricle stroke volume in healthy, eutrophic fetuses in the 2nd and 3rd trimesters evaluated using the velocity time integral and aortic annulus area with left ventricular stroke volume measured using Simpson's single‐plane rule and to determine the discrepancy equation.Methods: The study included 354 fetuses. In each fetus, during the same examination, simultaneous assessment of stroke volume was performed by pulsed‐wave Doppler using the product of the velocity time integral and aortic annulus area and by the fetalHQ® software using Simpson's single‐plane rule. The Mann–Whitney U test was used to compare the “product‐derived” stroke volume and stroke volume using fetalHQ® software values in the 2nd and 3rd trimesters separately. The agreement between the two methods were verified using Bland–Altman analysis. A linear regression model was used to obtain the discrepancy equation.Results: In the 2nd trimester, the mean percentage difference between both the techniques showed that the stroke volume values determined using pulsed‐wave Doppler were, on average, 88% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 146% and the lower limit of agreement was equal to 29.6%. In the 3rd trimester, the results indicated that the stroke volume values determined using pulsed‐wave Doppler were, on average, 76% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 129% and the lower limit of agreement was 23%. Based on the results of the linear regression models, discrepancy formulas of the stroke volume values were obtained. The equations to calculate the predicted mean and standard deviations were used to compute the reference intervals for the mean, 5th and 95th centiles.Conclusion: The calculation of left ventricular stroke volume using pulsed Doppler has higher result in relation to stroke volume determined using Simpson's rule significantly. The aortic annulus area showed a higher correlation regarding stroke volume than the velocity time integral in both the 2nd and 3rd trimesters. Stroke volume increased with the increase in aortic annulus area, whereas the velocity time integral remained relatively constant. The retrospective analysis of the collected material enabled the determination of the discrepancy equation.
- 3 April 2024
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 43 (7) , 1319-1331
Comparison of Left Ventricular Stroke Volume in 2nd‐ and 3rd‐Trimester Fetuses Measured by the Product of VTI and Aortic Annular Area With That Assessed by Simpson's Single‐Plane Rule Using the STE Technique
Objectives: The aim of the study was to compare left ventricle stroke volume in healthy, eutrophic fetuses in the 2nd and 3rd trimesters evaluated using the velocity time integral and aortic annulus area with left ventricular stroke volume measured using Simpson's single‐plane rule and to determine the discrepancy equation.Methods: The study included 354 fetuses. In each fetus, during the same examination, simultaneous assessment of stroke volume was performed by pulsed‐wave Doppler using the product of the velocity time integral and aortic annulus area and by the fetalHQ® software using Simpson's single‐plane rule. The Mann–Whitney U test was used to compare the “product‐derived” stroke volume and stroke volume using fetalHQ® software values in the 2nd and 3rd trimesters separately. The agreement between the two methods were verified using Bland–Altman analysis. A linear regression model was used to obtain the discrepancy equation.Results: In the 2nd trimester, the mean percentage difference between both the techniques showed that the stroke volume values determined using pulsed‐wave Doppler were, on average, 88% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 146% and the lower limit of agreement was equal to 29.6%. In the 3rd trimester, the results indicated that the stroke volume values determined using pulsed‐wave Doppler were, on average, 76% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 129% and the lower limit of agreement was 23%. Based on the results of the linear regression models, discrepancy formulas of the stroke volume values were obtained. The equations to calculate the predicted mean and standard deviations were used to compute the reference intervals for the mean, 5th and 95th centiles.Conclusion: The calculation of left ventricular stroke volume using pulsed Doppler has higher result in relation to stroke volume determined using Simpson's rule significantly. The aortic annulus area showed a higher correlation regarding stroke volume than the velocity time integral in both the 2nd and 3rd trimesters. Stroke volume increased with the increase in aortic annulus area, whereas the velocity time integral remained relatively constant. The retrospective analysis of the collected material enabled the determination of the discrepancy equation.