Open Access
- 19 March 2024
- journal article
- review article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 15-27
Abstract
Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real‐time, motion‐robust, and volumetric MR thermometry. However, current technologies have inherent trade‐offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting‐edge MRI techniques for motion‐robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion‐robust MR thermometry strategies and inspire the development of motion‐robust volumetric MR thermometry for practical use in clinics.Keywords
Funding Information
- National Institute of Dental and Craniofacial Research (K99DE032397)
This publication has 58 references indexed in Scilit:
- Proton Resonance Frequency Shift Thermometry: A Review of Modern Clinical PracticesJournal of Magnetic Resonance Imaging, 2020
- Fat‐referenced MR thermometry in the breast and prostate using IDEALJournal of Magnetic Resonance Imaging, 2012
- Measurement of temperature dependent changes in bone marrow using a rapid chemical shift imaging techniqueJournal of Magnetic Resonance Imaging, 2011
- MR thermometryJournal of Magnetic Resonance Imaging, 2008
- Echo combination to reduce proton resonance frequency (PRF) thermometry errors from fatJournal of Magnetic Resonance Imaging, 2007
- Correction of proton resonance frequency shift temperature maps for magnetic field disturbances using fat signalJournal of Magnetic Resonance Imaging, 2007
- Real‐time monitoring of radiofrequency ablation of rabbit liver by respiratory‐gated quantitative temperature MRIJournal of Magnetic Resonance Imaging, 2006
- Interleaved echo‐planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapyJournal of Magnetic Resonance Imaging, 2004
- Real‐time MR temperature mapping of rabbit liver in vivo during thermal ablationMagnetic Resonance in Medicine, 2003
- A fast calculation method for magnetic field inhomogeneity due to an arbitrary distribution of bulk susceptibilityConcepts in Magnetic Resonance Part B, 2003