KKKisoo Kim

Kisoo Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kisoo Kim has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microbubble Timing and Vascular Geometry Are Associated With Vessel‐Level Blood–Brain Barrier Opening During Focused Ultrasound

    by Seongdong Park, Hyemin Lee, Seunghwan Choi, Juyoung Park, Sun Kwang Kim, Kisoo Kim

    Objectives: To examine whether minute‐scale microbubble handling and injection‐to‐sonication timing are associated with vessel‐level focused ultrasound (FUS)–mediated blood–brain barrier opening (BBBO), and whether control normalization improves longitudinal 2‐photon (2P) measurements. Methods: Cranial‐windowed mice received FITC–dextran (40 kDa) and SonoVue microbubbles by retro‐orbital injection, followed by 1.0 MHz FUS at 0.2–0.4 MPa. Two‐photon stacks were acquired over 0–15 minutes. Frangi vesselness and Otsu thresholding defined vessel masks and a perivascular ring for extravasation analysis. Three timing conditions were compared: standard (injection within ~5 seconds of reconstitution, sonication immediately); Microbubble Floating (microbubbles held 2 minutes before injection); and Sonication Delay (sonication started 2 minutes after injection). Per‐mouse AUC used 2‐way ANOVA; slice‐level vessel‐area dependence used a linear mixed‐effects model with mouse as a random intercept. Results: Control intravascular fluorescence decreased by ~24% over 15 minutes, showing that the intravascular signal is not a stable denominator; control‐normalized extravascular AUC was therefore the primary metric. Under the standard protocol, extravascular AUC peaked at 0.3 MPa, but the across‐pressure difference was not significant ( F (2,6) = 3.36, p = .105). Timing effects were descriptive: relative to standard, both Microbubble Floating and Sonication Delay increased extravascular AUC at 0.2 MPa but decreased it at 0.3 MPa. Vessel area was inversely associated with extravasation at the slice level ( β = −0.37 per μm 2 , p = .010), with mouse‐level intraclass correlation (ICC = 0.80) indicating dominant between‐mouse variability. Conclusions: Microbubble handling and injection‐to‐sonication timing are potential protocol variables in FUS‐BBBO studies. Control‐normalized extravascular metrics provide a reproducible framework for vessel‐level longitudinal 2‐photon quantification.

  • Open Access

    A semi-automated natural language processing-based analytical pipeline for identifying structural shifts in MRI safety incidents: an analysis of FDA MAUDE reports (2018–2024)

    by Jeongin Lee, Seongdong Park, Jiwon Jung, Jinwoo Hwang, Seon-Eui Hong, Yeun-Chul Ryu, Myung Kyun Woo, Kisoo Kim, Sukhoon Oh

    Despite the widespread adoption of magnetic resonance imaging (MRI), safety incidents during MRI examinations continue to be reported. Building upon prior FDA-led analyses of MAUDE data, this study extends the temporal scope and analytical depth to systematically examine MRI-related adverse events reported between 2018 and 2024. Using a semi-automated classification framework that combined keyword-based text analysis with expert review, MRI-related incidents were categorized into granular safety domains, and inter-category correlations and associations were analyzed to characterize incident patterns at the level of individual events. The results demonstrate that MRI-related incidents persist annually, with no substantial reduction observed in Operation- and RF/Gradient-related events, which together account for a large proportion of reported cases. In parallel, implant-related incidents have become increasingly prominent and are associated with the majority of reported MRI events, extending beyond any single failure category. Although further subclassification of implant-related incidents was attempted, substantial semantic overlap among incident descriptions highlighted the complex and intertwined nature of implant-associated MRI safety challenges. Overall, these findings indicate that contemporary MRI safety risks are increasingly shaped by interactions among implants, software-based systems, and operational factors, rather than isolated hardware failures alone. Furthermore, the developed analytical pipeline establishes a reproducible measurement framework for large-scale medical device surveillance. This study provides data-driven insights that may inform future medical device design, more conservative MRI safety guidelines, and expanded education for both medical professionals and patients.

  • Open Access

    Evaluation of the association between MREPT-derived conductivity and IVIM-derived ISF-related metrics in the brains of patients with cognitive impairments

    by Jiwon Jung, Nitish Katoch, Hak Young Rhee, Yu Jin Jung, Yoon Kim, Soonchan Park, Chang-Woo Ryu, Kisoo Kim, Geon-Ho Jahng

    Background: Alterations in the ionic microenvironment and interstitial fluid (ISF) dynamics are increasingly recognized as early pathological events in Alzheimer’s disease (AD). However, the in vivo relationship between bulk tissue electrical properties and ISF mobility remains unclear. Purpose: This study aimed to investigate the relationship between magnetic resonance electrical properties tomography (MREPT)-derived high-frequency conductivity (HFC) and intravoxel incoherent motion (IVIM)-derived ISF-related metrics in patients with cognitive impairments across the cognitively normal to AD spectrum. Methods: A total of 161 participants (26 cognitively normal (CN), 78 with amnestic mild cognitive impairment (MCI), and 57 with AD) underwent 3.0 T MRI. HFC maps were reconstructed using phase-based MREPT. ISF-related diffusion (D ISF ) and volume fraction (F ISF ) indices were extracted from multi-b-value IVIM data using an unsupervised physics-informed neural network (PINN) approach. Voxel-based and region-of-interest (ROI) statistical analyses, including ANCOVA, partial correlations, and robust multiple regressions, were performed with adjustments for age and sex. Results: Along the disease progression from CN to AD, D ISF significantly decreased, while F ISF and HFC increased. Partial correlation analyses revealed that these alterations were significantly correlated with age and cognitive decline. Furthermore, MREPT-derived HFC exhibited region-specific correlations with IVIM-derived ISF-related measures, most notably in the bilateral corpus callosum and thalamus. Robust multiple regression analyses revealed limited, region-specific independent associations between ISF indices and HFC, with the most robust finding observed for D ISF in the left thalamus, whereas F ISF -related associations did not survive correction, and F PAR showed the most consistent independent association in the volume-fraction model. Conclusion: The region-specific associations observed between MREPT-derived HFC and IVIM-derived ISF-related metrics in select AD-vulnerable regions, particularly the independent D ISF –HFC association in the left thalamus, suggest that neurodegeneration may be linked with local ionic and microenvironmental compartmental shifts. These findings require replication in larger, independent cohorts. Combining MREPT and IVIM-based ISF-related metrics may provide a non-invasive imaging framework to probe these complex microenvironmental alterations in cognitive impairment.

  • Open Access

    Evaluation of Low-Dose Radiation Treatment Effects Using Conductivity, Diffusivity, and Brain Tissue Volumes Treated in Patients with Mild Alzheimer’s Disease: Exploratory Investigation

    by Weon Kuu Chung, Hwang Mi Kim, Mun Bae Lee, Kisoo Kim, Oh-In Kwon, Ye Jin Yoo, Hak Young Rhee, Geon-Ho Jahng

    Purpose: No prior clinical studies have quantitatively evaluated the effect of low-dose radiation therapy (LDRT) on Alzheimer’s disease (AD) brain changes using multi-modal MRI. This study examined the feasibility of using conductivity, diffusion, and brain tissue volume measures to detect treatment effects in patients with AD receiving LDRT. Methods: Nine patients with mild AD were enrolled in three groups. Three patients in each group were assigned to the control group (0 cGy) and the treated groups [24 cGy/6 fractions (4 cGy for each fraction) and 300 cGy/6 fractions (50 cGy for each fraction)]. Conductivity, diffusivity, and brain tissue volume were acquired at baseline and 6 months post-treatment and were evaluated to assess within-group MRI changes and evaluate associations between MRI measures and Mini-Mental State Examination (MMSE) scores. Results: Region-of-interest (ROI) analyses identified substantial changes in high-frequency conductivity (HFC) (e.g., left insula), cerebrospinal fluid (CSF) volumes (e.g., anterior cingulate, limbic regions), and diffusion tensor imaging (DTI) metrics, such as axial diffusivity (AxD) and fractional anisotropy (FA), in fusiform, thalamic, hippocampal, and occipital areas. Correlation analysis showed strong associations between MRI measures and cognition, most notably HFC in the left fusiform gyrus (r = 0.843, p = 0.0043) after treatment. Diffusion indices across multiple regions also showed significant positive or negative correlations with MMSE. Conclusions: This exploratory clinical study demonstrates that LDRT induces measurable physiological and microstructural alterations in the brain detectable via conductivity and diffusion MRI. Conductivity emerged as the sensitive biomarker, showing strong cognitive correlations. These exploratory findings suggest that multi-modal quantitative MRI can serve as an effective tool for evaluating treatment response in clinical LDRT for AD.

  • Interventional MR Elastography for the monitoring of thermal ablations

    by Kisoo Kim

    Élastographie par Résonance Magnétique (ERM) Interventionnelle pour le suivi des ablations thermiques: L'ablation thermique vise à endommager les cellules tumorales en chauffant ou en congelant le tissu tumoral. La surveillance par IRM est une technique prometteuse pour assurer la destruction des cellules tumorales tout en aidant à préserver les tissus sains environnants. L'équipe ICube a récemment proposé l'utilisation de l'élastographie RM en temps réel (MRE) et de la thermométrie RM (MRT). Cela permet de surveiller la température et les propriétés mécaniques du tissu ciblé simultanément en temps réel. Dans cette thèse de doctorat , nous avons présenté deux développements différents afin de surmonter certaines des limitations actuelles de la MRE et de la MRT interventionnelles, en termes d’extension à la couverture spatiale de la région ciblée et au développement d’une nouvelle méthode de surveillance des ablations thermiques pour tous les types de tissus mous, y compris les tissus adipeux. Ces contributions visent à améliorer la sécurité et l'efficacité de l'ablation thermique guidée par MR.

  • Open Access

    Design of multi-modal antenna arrays for microwave hyperthermia and 1H/1⁹F MRI monitoring of drug release

    by Daniel Hernandez, Taewoo Nam, Eunwoo Lee, Jae Jun Lee, Kisoo Kim, Kyoung Nam Kim

    This simulation-based study presented a novel hybrid RF antenna array designed for neck cancer treatment within a 7T MRI system. The proposed design aimed to provide microwave hyperthermia to release 19F-labeled anticancer drugs from thermosensitive liposomes, facilitating drug concentration monitoring through 19F imaging and enabling 1H anatomical imaging and MR thermometry for temperature control. The design featured a bidirectional microstrip for generating the magnetic |B1|-fields required for 1H and 19F MR imaging, along with a patch antenna for localized RF heating. The bidirectional microstrip was operated at 300 MHz and 280 MHz through the placement of excitation ports at the ends of the antenna and an asymmetric structure along the antenna. Additionally, a patch antenna was positioned at the center. Based on this setup, an array of six antennas was designed. Simulation results using a tissue-mimicking simulation model confirmed the intensity and uniformity of |B1|-fields for both 19F and 1H nuclei, demonstrating the suitability of the design for clinical imaging. RF heating from the patch antennas was effectively localized at the center of the cancer model. In simulations with a human model, average |B1|-fields were 0.21 μT for 19F and 0.12 μT for 1H, with normalized-absolute-average-deviation values of 81.75% and 87.74%, respectively. Hyperthermia treatment was applied at 120 W for 600 s, achieving an average temperature of 40.22°C in the cancer model with a perfusion rate of 1 ml/min/kg. This study demonstrated the potential of a hybrid antenna array for integrating 1H MR, 19F drug monitoring, and hyperthermia.


  • Monitoring Blood-Brain Barrier Opening in Rats with a Preclinical Focused Ultrasound System

    by Kisoo Kim, Marco Gallus, Tianrun Xiao, Akshay S. Parchure, Bhavya R. Shah, Hideho Okada, Chris Diederich, Eugene Ozhinsky, Kazim Narsinh

    The brain has a highly selective semipermeable blood barrier, termed the blood-brain barrier (BBB), which prevents the delivery of therapeutic ... Jove


  • Open Access

    Volumetric hyperthermia delivery using the ExAblate Body MR-guided focused ultrasound system

    by Kisoo Kim, Pragya Gupta, Kazim Narsinh, Chris J. Diederich, Eugene Ozhinsky

    To investigate image-guided volumetric hyperthermia strategies using the ExAblate Body MR-guided focused ultrasound ablation system, involving mechanical transducer movement and sector-vortex beamforming. Acoustic and thermal simulations were performed to investigate volumetric hyperthermia using mechanical transducer movement combined with sector-vortex beamforming, specifically for the ExAblate Body transducer. The system control in the ExAblate Body system was modified to achieve fast transducer movement and MR thermometry-based hyperthermia control, mechanical transducer movements and electronic sector-vortex beamforming were combined to optimize hyperthermia delivery. The experimental validation was performed using a tissue-mimicking phantom. The developed simulation framework allowed for a parametric study with varying numbers of heating spots, sonication durations, and transducer movement times to evaluate the hyperthermia characteristics for mechanical transducer movement and sector-vortex beamforming. Hyperthermic patterns involving 2-4 sequential focal spots were analyzed. To demonstrate the feasibility of volumetric hyperthermia in the system, a tissue-mimicking phantom was sonicated with two distinct spots through mechanical transducer movement and sector-vortex beamforming. During hyperthermia, the average values of Tmax, T10, Tavg, T90, and Tmin over 200 s were measured within a circular ROI with a diameter of 10 pixels. These values were found to be 8.6, 7.9, 6.6, 5.2, and 4.5 °C, respectively, compared to the baseline temperature. This study demonstrated the volumetric hyperthermia capabilities of the ExAblate Body system. The simulation framework developed in this study allowed for the evaluation of hyperthermia characteristics that could be implemented with the ExAblate MRgFUS system.


  • Open Access

    Technical advances in motion‐robust MR thermometry

    by Kisoo Kim, Kazim Narsinh, Eugene Ozhinsky

    Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real‐time, motion‐robust, and volumetric MR thermometry. However, current technologies have inherent trade‐offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting‐edge MRI techniques for motion‐robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion‐robust MR thermometry strategies and inspire the development of motion‐robust volumetric MR thermometry for practical use in clinics.


  • Open Access

    MR Thermometry during Transcranial MR Imaging–Guided Focused Ultrasound Procedures: A Review

    by Raghav R. Mattay, Kisoo Kim, Lubdha Shah, Bhavya Shah, Leo Sugrue, Fatima Safoora, Eugene Ozhinsky, Kazim H. Narsinh

    SUMMARY: Interest in transcranial MR imaging–guided focused ultrasound procedures has recently grown. These incisionless procedures enable precise focal ablation of brain tissue using real-time monitoring by MR thermometry. This article will provide an updated review on clinically applicable technical underpinnings and considerations of proton resonance frequency MR thermometry, the most common clinically used MR thermometry sequence.