Free‐breathing whole‐heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation
- 8 December 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 181-189
Abstract
Purpose: To develop and validate a new prospective respiratory motion compensation algorithm for free‐breathing whole‐heart 3D cine steady‐state free precession (SSFP) imaging.Methods: In a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re‐purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end‐expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath‐hold 2D cine ventricular short‐axis stack and a free‐breathing whole‐heart 3D cine data set.Results: All 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end‐diastolic, end‐systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was < 6% except for right ventricular end‐systolic volume that was 12%. The 3D cine images had a lower ventricular blood‐to‐myocardium contrast ratio, contrast‐to‐noise ratio, mass, and subjective quality score.Conclusion: The novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath‐hold 2D cine imaging. Magn Reson Med 80:181–189, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- Boston Children's Hospital
- National Institutes of Health (KL2 TR001100)
- Charles H. Hood Foundation
This publication has 40 references indexed in Scilit:
- Advanced Respiratory Motion Compensation for Coronary MR AngiographySensors, 2013
- Quantitative analysis of cardiac left ventricular variables obtained by MRI at 3 T: a pre- and post-contrast comparisonBritish Journal of Radiology, 2012
- Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agentJournal of Cardiovascular Magnetic Resonance, 2012
- Single breath‐hold assessment of ventricular volumes using 32‐channel coil technology and an extracellular contrast agentJournal of Magnetic Resonance Imaging, 2010
- Single‐breathhold four‐dimensional assessment of left ventricular volumes and function using k‐t BLAST after application of extracellular contrast agent at 3 TeslaJournal of Magnetic Resonance Imaging, 2008
- Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSEJournal of Cardiovascular Magnetic Resonance, 2008
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effect of Intrathoracic Pressure on Left Ventricular PerformanceNew England Journal of Medicine, 1979