Single‐breathhold four‐dimensional assessment of left ventricular volumes and function using k‐t BLAST after application of extracellular contrast agent at 3 Tesla
Open Access
- 18 April 2008
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (5) , 1028-1036
Abstract
Purpose To prospectively determine the feasibility and accuracy of a four‐dimensional (4D) k‐space over time broad‐use linear acquisition speed‐up technique (k‐t BLAST) for the evaluation of left ventricular (LV) volumes in comparison to standard multiple‐breathhold cine imaging, using a 3.0 Tesla (3T) MR system. Materials and Methods In 23 subjects, short‐axis cine loops completely covering the LV were acquired using conventional turbo gradient echo (GRE) imaging. Immediately after administration of gadobenate dimeglumine, a rapid single‐breathhold k‐t BLAST 4D dataset with the same coverage was acquired and reconstructed to short‐axis views. Quantitative aortic flow measurement for LV stroke volume (LVSV) was used to calibrate both techniques. For GRE and k‐t BLAST cine imaging: LV volumes, ejection fraction (EF), and blood‐to‐myocardium‐contrast (BMC) were determined. Results k‐t BLAST and GRE sequences showed a strong correlation for LV volumes and EF (r = 0.97–0.99; P < 0.001). Excellent agreement was also found between the LVSV determined by aortic flow measurements and LVSV assessed using GRE sequence and k‐t BLAST sequence. BMC of GRE was similar to that of k‐t BLAST cine imaging. Conclusion The use of the single‐breathhold 4D k‐t BLAST technique for the assessment of LV volume is feasible and accurate in 3T MRI. J. Magn. Reson. Imaging 2008;27:1028–1036.Keywords
This publication has 27 references indexed in Scilit:
- Four‐dimensional single breathhold magnetic resonance imaging using kt‐BLAST enables reliable assessment of left‐ and right‐ventricular volumes and massJournal of Magnetic Resonance Imaging, 2007
- Accelerated 4D Dobutamine Stress MR Imaging with k-t BLAST: Feasibility and Diagnostic PerformanceRadiology, 2006
- Analysis of Cardiac Function???Comparison Between 1.5 Tesla and 3.0 Tesla Cardiac Cine Magnetic Resonance ImagingInvestigative Radiology, 2006
- Cardiac Steady-State Free Precession CINE Magnetic Resonance Imaging at 3.0 TeslaInvestigative Radiology, 2006
- Optimizing spatiotemporal sampling for k‐t BLAST and k‐t SENSE: Application to high‐resolution real‐time cardiac steady‐state free precessionMagnetic Resonance in Medicine, 2005
- Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?European Heart Journal, 2004
- On the influence of training data quality in k‐t BLAST reconstructionMagnetic Resonance in Medicine, 2004
- Accelerating cardiac cine 3D imaging using k‐t BLASTMagnetic Resonance in Medicine, 2004
- k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlationsMagnetic Resonance in Medicine, 2003
- Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis.Radiology, 1993