H-infinity controller design for blood glucose regulation in diabetes patients in the presence of uncertain parameters
Authors:
- 1 May 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
This paper presents deals with uncertain description of a system for a type I diabetes mellitus patient under an intensive insulin treatment. The control algorithm employs a robust H∞ controller to regulate the blood glucose level in diabetic patients. Diabetes mellitus is a kind of chronic metabolic diseases in which body's blood glucose regulatory system doesn't function properly. In this study, Bergman's minimal model has been used as a base model, to increase the functionalities of the glucose minimal model, some additions could be done. One of the additions is the exercise model and since it is hard to derive exact value of parameters in most biological systems, all parameters of the model has been considered uncertain and therefore parametric uncertainty has been exploited in control design. The control scheme is based on closed-loop feedback strategy. The behavior of the obtained controller was analyzed on ability to track a normoglycemic set point of 81mg/dl in presence of disturbance and course tracking of the closed loop with the nominal system and the system with perturbed parameters. The designed controller proved effective in achieving normoglycaemic and robust to meal and exercise disturbances.Keywords
This publication has 15 references indexed in Scilit:
- High-order sliding-mode control for blood glucose: Practical relative degree approachControl Engineering Practice, 2013
- A switching control strategy for the attenuation of blood glucose disturbancesOptimal Control Applications and Methods, 2011
- A semiclosed-loop optimal control system for blood glucose level in diabeticsJournal of Medical Engineering & Technology, 2004
- Active insulin infusion using optimal and derivative-weighted controlMedical Engineering & Physics, 2002
- Robust H∞ glucose control in diabetes using a physiological modelAIChE Journal, 2000
- A robust controller for insulin pumps based on H-infinity theoryIEEE Transactions on Biomedical Engineering, 1993
- A semiclosed-loop algorithm for the control of blood glucose levels in diabeticsIEEE Transactions on Biomedical Engineering, 1991
- State-space solutions to standard H/sub 2/ and H/sub infinity / control problemsIEEE Transactions on Automatic Control, 1989
- Physiologic evaluation of factors controlling glucose tolerance in man: measurement of insulin sensitivity and beta-cell glucose sensitivity from the response to intravenous glucose.Journal of Clinical Investigation, 1981
- An Artificial Endocrine PancreasDiabetes, 1974