Abstract
The paper deals with the analysis of balanced voltage sags on V/f adjustable speed drive (ASD) of a gas compressor based on using Z-source inverter (ZSI). It has been shown that ZSI drastically extends the permissible range of DC-link voltage reduction. The voltage tolerance curves are obtained to estimate Z-source ASD immunity to balanced voltage sags. Stability of the investigated ASD system is provided by means of regulating ZSI shoot-through duty ratio. The simulation results are given to affirm presented features.Keywords
This publication has 11 references indexed in Scilit:
- Analysis of Z-source inverter control system for asynchronous drive for gas compressor2018
- Structure of energy consumption and improving open-pit dump truck efficiencyIOP Conference Series: Earth and Environmental Science, 2017
- IMPROVEMENT OF ENERGY EFFICIENCY, RELIABILITY AND ENVIRONMENTAL SAFETY OF POWER PLANTS BASED ON ASSOCIATED PETROLEUM GASJournal of Ecological Engineering, 2017
- The question of compensation overload neutral wire current in low voltage electrical networks2017
- Z-Source Inverter for Motor DrivesIEEE Transactions on Power Electronics, 2005
- Design-oriented analysis of DC bus dynamics in adjustable speed drives under input voltage unbalance and sag conditions2004
- Z-source inverter for adjustable speed drivesIEEE Power Electronics Letters, 2003
- Ride-through of adjustable speed drives during voltage dipsElectric Power Systems Research, 2003
- Z-source inverterIEEE Transactions on Industry Applications, 2003
- Controlled AC drives with ride-through capability at power interruptionIEEE Transactions on Industry Applications, 1994