Aleksey A. Belsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aleksey A. Belsky has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Vasiliy S. Dobush
Department of General Electrical Engineering, Saint-Petersburg Mining University, 199106 Saint-Petersburg, Russia
10 shared publications - Daniil I. Ivanchenko
Electromechanical Department, National Mineral Resources University (Mining University), Saint Petersburg, Russian Federation
5 shared publications - Aleksandr N. Skamyin
Saint Petersburg Mining University
2 shared publications - Dmitry Glukhanich
Saint-Petersburg Mining University
2 shared publications - Mohd Hatta Jopri
Universiti Teknikal Malaysia Melaka
2 shared publications - Tole Sutikno
Universitas Ahmad Dahlan
2 shared publications
Latest Publications
- 22 July 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 224
Analysis of specifications of bifacial photovoltaic panels
- 22 July 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 224
Analysis of specifications of bifacial photovoltaic panels
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3202-3214
Estimation of hourly solar irradiation on tilted surfaces
Tilted photovoltaic panel (PVP) are extensively utilized in solar power installations. To model and design them, you must understand the solar irradiation on a tilted surface over time scales of an hour, day, week, month, or other period. However, most meteorological stations only record global horizontal irradiance (GHI). In this research, a method is proposed for translating hourly worldwide horizontal irradiation from the NASA POWER database into hourly global sun irradiation on a tilted surface utilizing regression analysis methods and numerical modeling methods based on an isotropic model of solar irradiation. In addition, this work proposes a method for establishing the regression reliance of the diffuse transmittance index on the clearness index for geographic areas where this relationship has not yet been empirically proven. To assess effectiveness, the results of the proposed technique and other authors' methods are compared with monthly average NASA POWER climatological data using evaluation methods such as mean bias error (MBE), mean absolute bias error (MABE), and root-mean-square error (RMSE). The study's findings can be used to construct, optimize, or anticipate the functioning of solar power facilities at any angle of tilt and in any geographic area.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3202-3214
Open AccessEstimation of hourly solar irradiation on tilted surfaces
Tilted photovoltaic panel (PVP) are extensively utilized in solar power installations. To model and design them, you must understand the solar irradiation on a tilted surface over time scales of an hour, day, week, month, or other period. However, most meteorological stations only record global horizontal irradiance (GHI). In this research, a method is proposed for translating hourly worldwide horizontal irradiation from the NASA POWER database into hourly global sun irradiation on a tilted surface utilizing regression analysis methods and numerical modeling methods based on an isotropic model of solar irradiation. In addition, this work proposes a method for establishing the regression reliance of the diffuse transmittance index on the clearness index for geographic areas where this relationship has not yet been empirically proven. To assess effectiveness, the results of the proposed technique and other authors' methods are compared with monthly average NASA POWER climatological data using evaluation methods such as mean bias error (MBE), mean absolute bias error (MABE), and root-mean-square error (RMSE). The study's findings can be used to construct, optimize, or anticipate the functioning of solar power facilities at any angle of tilt and in any geographic area.
- 1 January 2023
- Published by FSB EIHE Omsk State Technical University in Omsk Scientific Bulletin
The analysis of power curves of wind power plants
The use of wind power plants is growing rapidly, despite the continued growth in the extraction of traditional fossil resources. In this paper, the analysis of the power curves of real wind turbine models and the polynomials common among the scientific community describing the dependence of the wind turbine output power on wind is carried out. The article discusses 82 models of wind power plants with a horizontal axis of rotation, rated power up to 100 kW and with a method of limiting the speed of rotation in the operating mode pitch control. The calculation of the potential generation of each wind turbine at an oil and gas field for a period of twenty years with an interval of one hour is carried out, the Installed Capacity Utilization Factor is calculated, after which the values are compared with the results of calculations based on polynomials of other authors. The results obtained can be widely applied in modeling the operating modes of wind power plants and will improve the accuracy of feasibility studies for the implementation of autonomous power supply systems.
- 1 January 2023
- Published by FSB EIHE Omsk State Technical University in Omsk Scientific Bulletin
The analysis of power curves of wind power plants
The use of wind power plants is growing rapidly, despite the continued growth in the extraction of traditional fossil resources. In this paper, the analysis of the power curves of real wind turbine models and the polynomials common among the scientific community describing the dependence of the wind turbine output power on wind is carried out. The article discusses 82 models of wind power plants with a horizontal axis of rotation, rated power up to 100 kW and with a method of limiting the speed of rotation in the operating mode pitch control. The calculation of the potential generation of each wind turbine at an oil and gas field for a period of twenty years with an interval of one hour is carried out, the Installed Capacity Utilization Factor is calculated, after which the values are compared with the results of calculations based on polynomials of other authors. The results obtained can be widely applied in modeling the operating modes of wind power plants and will improve the accuracy of feasibility studies for the implementation of autonomous power supply systems.
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Identification of harmonic source location in power distribution network
This paper presents the experimental set-up of identification of harmonic source location in the power distribution network using time-frequency analysis, known as S-transform (ST) at the point of common coupling (PCC). S-transform offers high frequency resolution in analyzing the low frequency component and able to represent signal parameters in time-frequency representation (TFR) such as TFR impedance (ZTFR). The proposed method is based on IEEE Std. 1459-2010, ST, and the significant relationship of spectral impedances components (ZS) that been extracted from the ZTFR, consist of the fundamental impedance (Z1) and harmonic impedance (Zh). This experiment was conducted out on an IEEE 4-bus test feeder with a harmonic producing load in numerous different scenarios. The experimental was tested and verified for three consecutive months. The findings of this study reveal that the proposed method provides 100 percent correct identification of harmonic source location.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessIdentification of harmonic source location in power distribution network
This paper presents the experimental set-up of identification of harmonic source location in the power distribution network using time-frequency analysis, known as S-transform (ST) at the point of common coupling (PCC). S-transform offers high frequency resolution in analyzing the low frequency component and able to represent signal parameters in time-frequency representation (TFR) such as TFR impedance (ZTFR). The proposed method is based on IEEE Std. 1459-2010, ST, and the significant relationship of spectral impedances components (ZS) that been extracted from the ZTFR, consist of the fundamental impedance (Z1) and harmonic impedance (Zh). This experiment was conducted out on an IEEE 4-bus test feeder with a harmonic producing load in numerous different scenarios. The experimental was tested and verified for three consecutive months. The findings of this study reveal that the proposed method provides 100 percent correct identification of harmonic source location.
- 11 February 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 159
Analysis of specifications of solar photovoltaic panels
- 11 February 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 159
Analysis of specifications of solar photovoltaic panels
- Open Access
- 1 January 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1441 (1) , 012020
Electro Steam Thermal Complex Powered by Wind-Driven Generator for the Treatment of the Oil Formation’s Bottomhole Area
In this article authors propose application of the wind-driven power units as power source of bottomhole electric steam generator for the thermal high-viscosity oil reservoir stimulation. The structure of the electro steam thermal complex is proposed. An analysis of the wind energy potential in the areas where the largest high-viscosity oil deposits in Russia are located is carried out. As part of the complex under consideration, the type of the dependence of the bottomhole electric steam generator’s power on the formation depth has been established. The calculation of the required installed capacity of wind power plants for placement as part of the electro steam thermal complex at the largest high-viscosity oil deposits in Russia has been performed.
- 1 January 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1441 (1) , 012020
Open AccessElectro Steam Thermal Complex Powered by Wind-Driven Generator for the Treatment of the Oil Formation’s Bottomhole Area
In this article authors propose application of the wind-driven power units as power source of bottomhole electric steam generator for the thermal high-viscosity oil reservoir stimulation. The structure of the electro steam thermal complex is proposed. An analysis of the wind energy potential in the areas where the largest high-viscosity oil deposits in Russia are located is carried out. As part of the complex under consideration, the type of the dependence of the bottomhole electric steam generator’s power on the formation depth has been established. The calculation of the required installed capacity of wind power plants for placement as part of the electro steam thermal complex at the largest high-viscosity oil deposits in Russia has been performed.
- Open Access
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012029
Autonomous power supply complex for oil leakage detection system in pipelines
In this article an autonomous power supply complex for oil leakage detection system is proposed for pipelines using the units of thermoelectric generators as a power source. Laboratory experimental studies were conducted as well as obtained operating energy characteristics of the complex. A sufficient number of the units of thermoelectric generators for uninterrupted power supply of the data collection point of the oil leak detection system has been defined.
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012029
Open AccessAutonomous power supply complex for oil leakage detection system in pipelines
In this article an autonomous power supply complex for oil leakage detection system is proposed for pipelines using the units of thermoelectric generators as a power source. Laboratory experimental studies were conducted as well as obtained operating energy characteristics of the complex. A sufficient number of the units of thermoelectric generators for uninterrupted power supply of the data collection point of the oil leak detection system has been defined.
- Open Access
- 4 April 2019
- Published by Belarusian National Technical University in ENERGETIKA. Proceedings of CIS Higher Education Institutions and Power Engineering Associations
- Vol. 62 (2) , 146-154
Wind Turbine Electrical Energy Supply System for Oil Well Heating
In this article, the authors reviewed a new technology to prevent the formation of asphalt-resin-paraffin deposits by the thermal method of electrothermal impact on the oil wellbore shaft using a wind-electric installation as an autonomous power source. The advantage of this thermal stimulation technique lies in its continuous nature, which will allow keeping the clear opening of the tubing constant. The scheme of the autonomous system for down-hole electric heating of oil is presented. A tubular or induction heater can serve as an electric heating element placed in the well. The heating element of the system can be used in the wells exploited by freeflow, gas lift and mechanized methods, while its installation does not require an overhaul. The paraffin oil saturation temperature and temperature distribution over the depth of the well were defined. The amount of heat, which must be transferred to the oil mixture in the tubing in order to ensure effective operation of the well, taking into account the dynamic state of the system, is calculated. The optimal depth of the heating element's location in the well and its power was determined. The calculation of the required power for wind-electric installation to maintain the set temperature in the wellbore was performed. Having conducted the studies, it was revealed that in order to prevent the asphalt-resin-paraffin deposits formation on the tubing walls of oil wells, it is expedient to use the in-line heater, which maintains the average steady-state temperature along the wellbore and at the wellhead above the initial crystallization point of the asphaltresin-paraffin deposits. The application of the developed electrothermal system is relevant in the conditions of formation of asphalt-resin-paraffin deposits in the wellbore shaft at the fields, which do not have a connection to the centralized power grid.
- 4 April 2019
- Published by Belarusian National Technical University in ENERGETIKA. Proceedings of CIS Higher Education Institutions and Power Engineering Associations
- Vol. 62 (2) , 146-154
Open AccessWind Turbine Electrical Energy Supply System for Oil Well Heating
In this article, the authors reviewed a new technology to prevent the formation of asphalt-resin-paraffin deposits by the thermal method of electrothermal impact on the oil wellbore shaft using a wind-electric installation as an autonomous power source. The advantage of this thermal stimulation technique lies in its continuous nature, which will allow keeping the clear opening of the tubing constant. The scheme of the autonomous system for down-hole electric heating of oil is presented. A tubular or induction heater can serve as an electric heating element placed in the well. The heating element of the system can be used in the wells exploited by freeflow, gas lift and mechanized methods, while its installation does not require an overhaul. The paraffin oil saturation temperature and temperature distribution over the depth of the well were defined. The amount of heat, which must be transferred to the oil mixture in the tubing in order to ensure effective operation of the well, taking into account the dynamic state of the system, is calculated. The optimal depth of the heating element's location in the well and its power was determined. The calculation of the required power for wind-electric installation to maintain the set temperature in the wellbore was performed. Having conducted the studies, it was revealed that in order to prevent the asphalt-resin-paraffin deposits formation on the tubing walls of oil wells, it is expedient to use the in-line heater, which maintains the average steady-state temperature along the wellbore and at the wellhead above the initial crystallization point of the asphaltresin-paraffin deposits. The application of the developed electrothermal system is relevant in the conditions of formation of asphalt-resin-paraffin deposits in the wellbore shaft at the fields, which do not have a connection to the centralized power grid.
- Open Access
- 26 March 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 489 (1) , 012013
Small wind-driven power plant operating experience
This paper addresses the operating experience of a small wind-driven power plant at Saint Petersburg Mining University. The paper describes the wind power generator operation, the deficiencies, revealed during the exploitation, as well as provides the recommendations for the plant improvement.
- 26 March 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 489 (1) , 012013
Open AccessSmall wind-driven power plant operating experience
This paper addresses the operating experience of a small wind-driven power plant at Saint Petersburg Mining University. The paper describes the wind power generator operation, the deficiencies, revealed during the exploitation, as well as provides the recommendations for the plant improvement.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 934-938
Balanced Voltage Sag Compensation on Adjustable Speed Drive of a Gas Compressor
The paper deals with the analysis of balanced voltage sags on V/f adjustable speed drive (ASD) of a gas compressor based on using Z-source inverter (ZSI). It has been shown that ZSI drastically extends the permissible range of DC-link voltage reduction. The voltage tolerance curves are obtained to estimate Z-source ASD immunity to balanced voltage sags. Stability of the investigated ASD system is provided by means of regulating ZSI shoot-through duty ratio. The simulation results are given to affirm presented features.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 934-938
Balanced Voltage Sag Compensation on Adjustable Speed Drive of a Gas Compressor
The paper deals with the analysis of balanced voltage sags on V/f adjustable speed drive (ASD) of a gas compressor based on using Z-source inverter (ZSI). It has been shown that ZSI drastically extends the permissible range of DC-link voltage reduction. The voltage tolerance curves are obtained to estimate Z-source ASD immunity to balanced voltage sags. Stability of the investigated ASD system is provided by means of regulating ZSI shoot-through duty ratio. The simulation results are given to affirm presented features.