A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
Open Access
- 13 May 2017
- journal article
- review article
- Published by Springer Nature in Diabetes Therapy
- Vol. 8 (3) , 489-506
Abstract
Introduction Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion. Few have focused on the fundamental limitations of this approach, especially regarding outcome measures beyond time in range. Methods Based on insulin physiology, the limitations of CGM, SC insulin absorption, meal challenge, and physical activity in DM1 patients, we discuss the limitations of the double SC approach. Finally, we discuss safety measures and the achievements reported in some recent AP studies that have utilized the double SC approach. Results Most studies show that a double SC AP increases the time in range compared to a sensor-augmented insulin pump and shortens the time in hypoglycemia. Despite these achievements, the proportion of time spent in hyperglycemia is still roughly 20–40%, and hypoglycemia is still present 1–4% of the time. The main factors limiting further progress are the latency of SC CGM (at least 5–10 min) and the slow pharmacokinetics of SC-delivered fast-acting insulin. The maximum blood insulin level is reached after 45 min and the maximum glucose-lowering effect is observed after 1.5–2 h, while the glucose-lowering effect lasts for at least 5 h. Conclusions Although using a double SC AP leads to significant improvements in glucose control, the SC approach has severe limitations that hamper further progress towards a robust AP.Keywords
Funding Information
- The Norwegian Research Council (248872)
- Liaison Committee for Central Norway Regional Health Authority (RHA) and the Norwegian University of Science and Technology (46075401, 46075403)
This publication has 100 references indexed in Scilit:
- Resistance Versus Aerobic ExerciseDiabetes Care, 2013
- Insulin-Pump Therapy for Type 1 Diabetes MellitusNew England Journal of Medicine, 2012
- Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 DiabetesDiabetes Care, 2011
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- First-phase insulin secretion: does it exist in real life? Considerations on shape and functionAmerican Journal of Physiology-Endocrinology and Metabolism, 2004
- Insulin Levels After Portal and Systemic Insulin Infusion Differ in a Dose-Dependent FashionHormone and Metabolic Research, 1998
- Persisting Mortality in Diabetic KetoacidosisDiabetic Medicine, 1993
- Basal and 24-h C-peptide and insulin secretion rate in normal manDiabetologia, 1987
- Severe Insulin-Induced Hypoglycemia Associated with Deficiencies in the Release of Counterregulatory HormonesNew England Journal of Medicine, 1981
- Evaluation of exogenous insulin homoeostasis by the artificial pancreas in insulin-dependent diabetesDiabetologia, 1977