Øyvind Stavdahl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Øyvind Stavdahl has a total of 134 co-authors. Here are the top co-authors by number of shared publications:
- Kristin Ytterstad Pettersen
Norwegian University of Science and Technology (NTNU)
43 shared publications - Jan Tommy Gravdahl
Department of Engineering Cybernetics, Norwegian University of Science and Technology, Trondheim, Norway
36 shared publications - Anders Lyngvi Fougner
Norwegian University of Science and Technology (NTNU)
18 shared publications Pal Liljeback
Dept. of Engineering Cybernetics, Norwegian University of Science and Technology, 7491 Trondheim, Norway
15 shared publications- Pål Liljebäck
SINTEF ICT
14 shared publications Lars Adde
Department of Laboratory Medicine, Children and Woman's Health, Faculty of Medicine, NTNU, Trondheim, Norway
5 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 410-424
Early Sound-Based Meal Onset Detection Using Hidden Markov Models (HMMs)
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 410-424
Open AccessEarly Sound-Based Meal Onset Detection Using Hidden Markov Models (HMMs)
- Open Access
- 30 September 2025
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 31 (1) , 185-201
Form closure-based path-planning in obstacle-aided locomotion for snake robots
Snake robots are hyperredundant manipulators with a wide range of potential applications ranging from search-and-rescue to ocean and outer space exploration. When snake robots use obstacles in the environment to push themselves forward it is referred to as obstacle-aided locomotion (OAL). The problem of finding a path that optimally exploits available obstacles in the environment for OAL currently does not have a general solution. A snake robot in contact with a set of obstacles is fundamentally similar to an object being grasped by a robotic hand. By interpreting the environment-robot contact as a grasp, we can employ the form closure concept for assessing the robustness of a given configuration; if the snake robot’s “grasp” of its environment has continual form closure when following a given path, the robot is guaranteed to not drift off that path. This presents a potential technique for analyzing the path-planning problem for OAL. This paper assesses the form closure of a rigid object on a planar surface by means of a novel method as well as a traditional method based on the grasp matrix. Furthermore, it introduces the notion of a form closure margin as a measure of how much a configuration must change before form closure is lost, and proposes three metrics that quantify this property. Finally, the applicability of the proposed metrics is demonstrated through their application to optimal path-planning for three specific scenarios. The results indicate that the proposed algorithm has strong potential to contribute to robust path-planning for OAL.
- 30 September 2025
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 31 (1) , 185-201
Open AccessForm closure-based path-planning in obstacle-aided locomotion for snake robots
Snake robots are hyperredundant manipulators with a wide range of potential applications ranging from search-and-rescue to ocean and outer space exploration. When snake robots use obstacles in the environment to push themselves forward it is referred to as obstacle-aided locomotion (OAL). The problem of finding a path that optimally exploits available obstacles in the environment for OAL currently does not have a general solution. A snake robot in contact with a set of obstacles is fundamentally similar to an object being grasped by a robotic hand. By interpreting the environment-robot contact as a grasp, we can employ the form closure concept for assessing the robustness of a given configuration; if the snake robot’s “grasp” of its environment has continual form closure when following a given path, the robot is guaranteed to not drift off that path. This presents a potential technique for analyzing the path-planning problem for OAL. This paper assesses the form closure of a rigid object on a planar surface by means of a novel method as well as a traditional method based on the grasp matrix. Furthermore, it introduces the notion of a form closure margin as a measure of how much a configuration must change before form closure is lost, and proposes three metrics that quantify this property. Finally, the applicability of the proposed metrics is demonstrated through their application to optimal path-planning for three specific scenarios. The results indicate that the proposed algorithm has strong potential to contribute to robust path-planning for OAL.
- Open Access
- 22 August 2025
- Published by Elsevier in Journal of Process Control
- Vol. 154
Dual hormone predictive control for a fully automated intraperitoneal artificial pancreas: Preclinical evaluation in pigs
- 22 August 2025
- Published by Elsevier in Journal of Process Control
- Vol. 154
Open AccessDual hormone predictive control for a fully automated intraperitoneal artificial pancreas: Preclinical evaluation in pigs
- Open Access
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 21723-21733
Toward Generality of a Framework for Quantifying Biomechanical Stability: Demonstration on the Ankle
This paper presents a mathematical description and experimental investigation of using an industrial robot to evaluate biomechanical stability in human cadaveric ankle specimens. We have previously proposed a methodology and parameterizable task space motion framework for biomechanical investigations of shoulders. The present study aimed to demonstrate the generality and use of our framework to replicate an ankle test protocol from the literature, and to experimentally evaluate the replicated test protocol. Stability tests in cadaveric studies can be performed by applying a known force or torque to the joint, and then measure the resulting linear or angular displacement. The relative stability between joint states can be determined by comparing the magnitude of motion, for example between the intact, injured, or surgically repaired joints. Increased joint motion between states can be interpreted as decreased stability, and decreased joint motion can be interpreted as increased stability. Comparing the motion between different states can be used to investigate the effects of soft tissue or bony structures on stability. The replicated protocol was tested in a technical pilot study using a fresh frozen human cadaveric ankle specimen. The specimen was tested in the intact state and in three subsequent injury states. However, this pilot study showed that the framework could successfully be parameterized to conduct tests on the ankle joint. The expected trend for subsequent injury states was progressive instability, and the observed trends from experimental testing aligned with this prior expectation. Additional work on the framework is necessary for it to be truly generalized.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 21723-21733
Open AccessToward Generality of a Framework for Quantifying Biomechanical Stability: Demonstration on the Ankle
This paper presents a mathematical description and experimental investigation of using an industrial robot to evaluate biomechanical stability in human cadaveric ankle specimens. We have previously proposed a methodology and parameterizable task space motion framework for biomechanical investigations of shoulders. The present study aimed to demonstrate the generality and use of our framework to replicate an ankle test protocol from the literature, and to experimentally evaluate the replicated test protocol. Stability tests in cadaveric studies can be performed by applying a known force or torque to the joint, and then measure the resulting linear or angular displacement. The relative stability between joint states can be determined by comparing the magnitude of motion, for example between the intact, injured, or surgically repaired joints. Increased joint motion between states can be interpreted as decreased stability, and decreased joint motion can be interpreted as increased stability. Comparing the motion between different states can be used to investigate the effects of soft tissue or bony structures on stability. The replicated protocol was tested in a technical pilot study using a fresh frozen human cadaveric ankle specimen. The specimen was tested in the intact state and in three subsequent injury states. However, this pilot study showed that the framework could successfully be parameterized to conduct tests on the ankle joint. The expected trend for subsequent injury states was progressive instability, and the observed trends from experimental testing aligned with this prior expectation. Additional work on the framework is necessary for it to be truly generalized.
- 30 August 2024
- Published by Springer Nature
- p. 755-762
Feasibility of Meal Onset Detection Using Electrocardiograms
- 30 August 2024
- Published by Springer Nature
- p. 755-762
Feasibility of Meal Onset Detection Using Electrocardiograms
- Open Access
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 29397-29413
Quantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework
This paper presents a methodology and generalized motion framework for quantifying passive biomechanical stability and Range of Motion of human cadaveric specimens, using a position-controlled industrial robot and a wrist-mounted force/torque sensor. Many biomechanical studies on diarthrodial joints using human cadaveric specimens are published in the literature, using various test protocols and machines to apply the loading conditions. In these studies, laxity or mobility of the joints are quantified by measuring the magnitude of translations and rotations with respect to force and torque. The protocols and anatomical motions of the specimens are usually described high-level, textually, and from a medical perspective to a broad audience. The present paper aims to describe, from a technical perspective to a robotics audience, our method to perform biomechanical studies and how existing protocols can be replicated through parameterization using the existing textual descriptions. To accomplish this, we propose a generalized task space motion framework for performing biomechanical studies on diarthrodial joints. The generalization is made by defining the Tool Center Point at the cadaveric joint rotation center and aligning the specimen so the anatomical motions can be modeled in world frame or tool frame. Our framework has the potential to rapidly automate new or existing protocols through parameterization, including protocols performed by machines other than industrial robots or serial manipulators. The framework was evaluated in a technical pilot study on the shoulder, using one cadaveric shoulder specimen and an established protocol. The specimen was tested in the intact state and in an injury state.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 29397-29413
Open AccessQuantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework
This paper presents a methodology and generalized motion framework for quantifying passive biomechanical stability and Range of Motion of human cadaveric specimens, using a position-controlled industrial robot and a wrist-mounted force/torque sensor. Many biomechanical studies on diarthrodial joints using human cadaveric specimens are published in the literature, using various test protocols and machines to apply the loading conditions. In these studies, laxity or mobility of the joints are quantified by measuring the magnitude of translations and rotations with respect to force and torque. The protocols and anatomical motions of the specimens are usually described high-level, textually, and from a medical perspective to a broad audience. The present paper aims to describe, from a technical perspective to a robotics audience, our method to perform biomechanical studies and how existing protocols can be replicated through parameterization using the existing textual descriptions. To accomplish this, we propose a generalized task space motion framework for performing biomechanical studies on diarthrodial joints. The generalization is made by defining the Tool Center Point at the cadaveric joint rotation center and aligning the specimen so the anatomical motions can be modeled in world frame or tool frame. Our framework has the potential to rapidly automate new or existing protocols through parameterization, including protocols performed by machines other than industrial robots or serial manipulators. The framework was evaluated in a technical pilot study on the shoulder, using one cadaveric shoulder specimen and an established protocol. The specimen was tested in the intact state and in an injury state.
- 19 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (11) , 7360-7367
Form Closure for Fully Actuated and Robust Obstacle-Aided Locomotion in Snake Robots
In this paper we adapt the theory of form closure to define the form closed region: The subset of a snake robot's configuration space for which the constraints imposed by the obstacles in its environment render the system fully actuated. We show that the identification of form closed configurations is numerically feasible, and introduce the relaxed condition of form boundedness to achieve robustness in the presence of model uncertainties. We moreover show an example application where the concept of form closed region is used to produce predictable constrained motion in a cluttered environment using lateral undulation.
- 19 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (11) , 7360-7367
Form Closure for Fully Actuated and Robust Obstacle-Aided Locomotion in Snake Robots
In this paper we adapt the theory of form closure to define the form closed region: The subset of a snake robot's configuration space for which the constraints imposed by the obstacles in its environment render the system fully actuated. We show that the identification of form closed configurations is numerically feasible, and introduce the relaxed condition of form boundedness to achieve robustness in the presence of model uncertainties. We moreover show an example application where the concept of form closed region is used to produce predictable constrained motion in a cluttered environment using lateral undulation.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Data-Driven Classifiers for Early Meal Detection Using ECG
This study investigates the potential of the electrocardiogram (ECG) to perform early meal detection, which is critical for developing a fully-functional automatic artificial pancreas. The study was conducted in a group of healthy subjects with different ages and genders. Two classifiers were trained: one based on neural networks (NNs) and working on features extracted from the signals; one based on convolutional NNs (CNNs) and working directly on raw data. During the test phase, both classifiers correctly detected all the meals, with the CNN outperforming the NN in terms of misdetected meals (MMs) and detection time (DT). Reliable meal onset detection with short detection time has significant practical implications: it reduces the risk of postprandial hyperglycemia and hypoglycemia, it reduces the mental burden of meal documentation for patients and related stress.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (9) , 1-4
Data-Driven Classifiers for Early Meal Detection Using ECG
This study investigates the potential of the electrocardiogram (ECG) to perform early meal detection, which is critical for developing a fully-functional automatic artificial pancreas. The study was conducted in a group of healthy subjects with different ages and genders. Two classifiers were trained: one based on neural networks (NNs) and working on features extracted from the signals; one based on convolutional NNs (CNNs) and working directly on raw data. During the test phase, both classifiers correctly detected all the meals, with the CNN outperforming the NN in terms of misdetected meals (MMs) and detection time (DT). Reliable meal onset detection with short detection time has significant practical implications: it reduces the risk of postprandial hyperglycemia and hypoglycemia, it reduces the mental burden of meal documentation for patients and related stress.
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (3) , 1273-1280
Low-Order Nonlinear Animal Model of Glucose Dynamics for a Bihormonal Intraperitoneal Artificial Pancreas
Objective: The design of an Artificial Pancreas (AP) to regulate blood glucose levels requires reliable control methods. Model Predictive Control has emerged as a promising approach for glycemia control. However, model–based control methods require computationally simple and identifiable mathematical models that represent glucose dynamics accurately, which is challenging due to the complexity of glucose homeostasis. Methods: In this work, a simple model is deduced to estimate blood glucose concentration in subjects with Type 1 Diabetes Mellitus (T1DM). Novel features in the model are power–law kinetics for intraperitoneal insulin absorption and a separate glucagon sensitivity state. Profile likelihood and a method based on singular value decomposition of the sensitivity matrix are carried out to assess parameter identifiability and guide a model reduction for improving the identification of parameters. Results: A reduced model with 10 parameters is obtained and calibrated, showing good fit to experimental data from pigs where insulin and glucagon boluses were delivered in the intraperitoneal cavity. Conclusion: A simple model with power–law kinetics can accurately represent glucose dynamics submitted to intraperitoneal insulin and glucagon injections. The reduced model was found to exhibit local practical as well as structural identifiability. Importance: The proposed model facilitates intraperitoneal bi-hormonal model-based closed-loop control in animal trials.
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (3) , 1273-1280
Low-Order Nonlinear Animal Model of Glucose Dynamics for a Bihormonal Intraperitoneal Artificial Pancreas
Objective: The design of an Artificial Pancreas (AP) to regulate blood glucose levels requires reliable control methods. Model Predictive Control has emerged as a promising approach for glycemia control. However, model–based control methods require computationally simple and identifiable mathematical models that represent glucose dynamics accurately, which is challenging due to the complexity of glucose homeostasis. Methods: In this work, a simple model is deduced to estimate blood glucose concentration in subjects with Type 1 Diabetes Mellitus (T1DM). Novel features in the model are power–law kinetics for intraperitoneal insulin absorption and a separate glucagon sensitivity state. Profile likelihood and a method based on singular value decomposition of the sensitivity matrix are carried out to assess parameter identifiability and guide a model reduction for improving the identification of parameters. Results: A reduced model with 10 parameters is obtained and calibrated, showing good fit to experimental data from pigs where insulin and glucagon boluses were delivered in the intraperitoneal cavity. Conclusion: A simple model with power–law kinetics can accurately represent glucose dynamics submitted to intraperitoneal insulin and glucagon injections. The reduced model was found to exhibit local practical as well as structural identifiability. Importance: The proposed model facilitates intraperitoneal bi-hormonal model-based closed-loop control in animal trials.
- 26 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 28 (3) , 1597-1607
Modeling Movement-Induced Errors in AC Electromagnetic Trackers
Error analysis of electromagnetic motion tracking systems is of growing interest to many researchers. Under sensor movement, it is logical to presume that the error in position and orientation measurements will increase due to the linearization used in the algorithms, among other reasons. In this article, we analyze theoretically the error, that results from linearization, in position measurement of the Polhemus tracking system for a moving sensor. We derive formulas to estimate this error in terms of the sensor position and speed. Then, we verify these formulas by numerical simulations.
- 26 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 28 (3) , 1597-1607
Modeling Movement-Induced Errors in AC Electromagnetic Trackers
Error analysis of electromagnetic motion tracking systems is of growing interest to many researchers. Under sensor movement, it is logical to presume that the error in position and orientation measurements will increase due to the linearization used in the algorithms, among other reasons. In this article, we analyze theoretically the error, that results from linearization, in position measurement of the Polhemus tracking system for a moving sensor. We derive formulas to estimate this error in terms of the sensor position and speed. Then, we verify these formulas by numerical simulations.