Accuracy of determination of the volemic status by remote dielectric sensing in comparison with computed tomography with simultaneous determination of respiratory profile using spirometry in patients with acute decompensation of heart failure
Open Access
- 27 May 2024
- journal article
- research article
- Published by Intermedservice Ltd in Eurasian heart journal
- No. 2,p. 96-100
Abstract
Aim. To evaluate and compare the accuracy of determining volemic status by remote dielectric sensing (ReDS) with computed tomography (CT) in patients with acute decompensated heart failure (ADHF).Materials and methods. In 33 patients with chronic heart failure (CHF) hospitalized in the hospital due to acute decompensation of heart failure, twice during hospitalization (on the day of admission and on the day of discharge from the hospital) the determination of the volemic status was performed using ReDS, chest computed tomography (CCT) and chest X-ray. ReDS measurement was compared with CT data using software that allows the use of semi-automated tools to determine mean lung tissue density (MLD). MLD results from Hounsfield units [HU] were converted to fluid levels (HU %), which allowed comparison with ReDS values. In addition, to assess the effect of physical activity on the dynamics of pulmonary congestion, a 6-minute walk test (6MWT) were performed with subsequent determination of the volemic status by the ReDS method.Results. A medium correlation was found between CCT and ReDS data (r = +6.0, p = 0.0002). In the dynamics statistically significant decrease of hypervolemia according to CCT data, which was reflected in the decrease of ReDS index. The fluid content in lungs according to ReDS on average at admission amounted to 37.1 ± 5.3%, at discharge 34.2 ± 4.1% (p = 0.0155). MLD according to CCT at admission was 26.5 ± 6.4 at discharge 22.7 ± 5.6 (P<0.0001). At the same time positive dynamics of NT-proBNP concentration was determined, which decreased by 45.6% (p = 0.0069). Differences in ReDS before and after physical activity 6MWT was revealed – 35.2 ± 4.2% in comparison with the initial index 34.2 ± 4.1% (p = 0.0001). A strong correlation was found between the ReDS score before and after 6MWT at discharge (r = +0.7, p = 0.0001)Keywords
This publication has 9 references indexed in Scilit:
- Possibilities of instrumental determination of volemic status in patients with acute decompensation of chronic heart failureTerapevticheskii arkhiv, 2023
- Integrative Assessment of Congestion in Heart Failure Throughout the Patient JourneyJACC: Heart Failure, 2018
- Validation of remote dielectric sensing (ReDS™) technology for quantification of lung fluid status: Comparison to high resolution chest computed tomography in patients with and without acute heart failureInternational Journal of Cardiology, 2016
- Genetic variation of the β2-adrenergic receptor is associated with differences in lung fluid accumulation in humansJournal of Applied Physiology, 2007
- Decompensated heart failure: symptoms, patterns of onset, and contributing factorsThe American Journal of Medicine, 2003
- Non-Invasive Imaging of Regional Lung Function using X-Ray Computed TomographyJournal of Clinical Monitoring and Computing, 2000
- Early Diagnosis and Estimation of Pulmonary Congestion and Edema in Patients With Left-Sided Heart Diseases From Histogram of Pulmonary CT NumberChest, 1996
- Estimation of pulmonary water distribution and pulmonary congestion by computed tomography.Japanese Heart Journal, 1982
- Density patterns in the normal lung as determined by computed tomography.Radiology, 1980