ASA. A. Syrkhaeva

A. A. Syrkhaeva

*This is an algorithmically generated author record based on publicly available information.

A. A. Syrkhaeva has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy of determination of the volemic status by remote dielectric sensing in comparison with computed tomography with simultaneous determination of respiratory profile using spirometry in patients with acute decompensation of heart failure

    by A. A. Syrkhaeva, M. A. Shariya, S. N. Nasonova, I. V. Zhirov, A. V. Shirkin, S. N. Tereshchenko, S. K. Ternovoy

    Aim. To evaluate and compare the accuracy of determining volemic status by remote dielectric sensing (ReDS) with computed tomography (CT) in patients with acute decompensated heart failure (ADHF).Materials and methods. In 33 patients with chronic heart failure (CHF) hospitalized in the hospital due to acute decompensation of heart failure, twice during hospitalization (on the day of admission and on the day of discharge from the hospital) the determination of the volemic status was performed using ReDS, chest computed tomography (CCT) and chest X-ray. ReDS measurement was compared with CT data using software that allows the use of semi-automated tools to determine mean lung tissue density (MLD). MLD results from Hounsfield units [HU] were converted to fluid levels (HU %), which allowed comparison with ReDS values. In addition, to assess the effect of physical activity on the dynamics of pulmonary congestion, a 6-minute walk test (6MWT) were performed with subsequent determination of the volemic status by the ReDS method.Results. A medium correlation was found between CCT and ReDS data (r = +6.0, p = 0.0002). In the dynamics statistically significant decrease of hypervolemia according to CCT data, which was reflected in the decrease of ReDS index. The fluid content in lungs according to ReDS on average at admission amounted to 37.1 ± 5.3%, at discharge 34.2 ± 4.1% (p = 0.0155). MLD according to CCT at admission was 26.5 ± 6.4 at discharge 22.7 ± 5.6 (P<0.0001). At the same time positive dynamics of NT-proBNP concentration was determined, which decreased by 45.6% (p = 0.0069). Differences in ReDS before and after physical activity 6MWT was revealed – 35.2 ± 4.2% in comparison with the initial index 34.2 ± 4.1% (p = 0.0001). A strong correlation was found between the ReDS score before and after 6MWT at discharge (r = +0.7, p = 0.0001)

  • Open Access

    Possibilities of instrumental determination of volemic status in patients with acute decompensation of chronic heart failure

    by A A Syrkhaeva, S N Nasonova, I V Zhirov, U A Khalilova, A V Shirkin, M A Shariya, S N Tereshchenko

    Aim. To evaluate and compare the accuracy of volemic status determination by remote dielectric sensing with computed tomography (CT) in patients with acute decompensated heart failure. Materials and methods. In 28 patients volemic status was determined by ReDS (remote dielectric sensing), chest computed tomography (CCT), and chest X-ray twice during hospitalization (the day of admission and the day of discharge from the hospital). The ReDS measurements were then compared with CT data using software that allows the use of semi-automated tools to determine mean lung density (MLD). MLD results from Hounsfield Units [HU] were then converted to fluid levels (FU%), allowing them to be compared with ReDS values. In addition, to assess the effect of physical activity on the dynamics of pulmonary stasis there was performed 6-minute walk test (6MWT) followed by determination of volumic status by ReDS method. Results. Correlation analysis revealed an average direct significant correlation (r=+0,5; p=0.001) between the CCT and ReDS data. Hypervolemia indexes according to the CCT revealed statistically significant decrease in the dynamics, which was also reflected in the ReDS index decrease. Lung fluid content according to ReDS averaged 38.24.6% on admission, and 34.53.9% on discharge (p=0.005). According to CT scan of the CCT, MLD at admission was 23.033.9%, at discharge 19.63.3% (p=0.003). The positive dynamics of the study methods was also reflected in the positive dynamics of NT-proBNP, which decreased by 46%. In the analysis of ReDS data before and after exercise, there was an increase in ReDS value after the performed 6MWT and it was 35.093.9% compared with the initial value of 34.53.9%. A strong direct significant correlation (r=+0.7; p=0.0001) was found between the ReDS before and after 6MWT at discharge.


  • Open Access

    Optimization of intravascular volume determination in patients with acute decompensated heart failure

    by I. V. Zhirov, S. N. Nasonova, A. A. Syrkhaeva, A. E. Lapteva, Yu. F. Osmolovskaya, O. M. Reitblat, Yu. Sh. Prints, M. A. Shariya, S. N. Tereshchenko, Ю. Ф. Осмоловская

    Acute decompensated heart failure (ADHF) is based on multilevel pathological pathways, which include hemodynamic overload and venous stasis. Determination of the volemic status is one of the most important tasks in managing such patients. Despite the availability of modern diagnostic markers (physical examination, chest x-ray, and brain natriuretic peptide (BNP) assessment), they do not accurately assess the degree of fluid overload, and therefore there remains a need to find a new, accurate and simple technology for assessing pulmonary congestion. The urgency of this problem has led to the development of a novel non-invasive remote dielectric sensing (ReDS) technology, which is a quantitative method for measuring the total volume of lung fluid by determining the tissue dielectric properties. The use of this technology makes it possible to quickly, non-invasively and quantitatively measure the fluid content in the lungs, makes it possible to optimize the treatment regimen and reduces the number of readmissions. This article presents the results of studies on the efficacy, safety and prospects for using a ReDS technology for the quantitative measurement of total lung fluid in patients with ADHF.