A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting
- 16 March 2016
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 44 (10) , 2863-2873
Abstract
This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually observable image artifact. The targeting accuracy is evaluated with optical tracking system and gelatin phantom under live MRI-guidance with Root Mean Square (RMS) errors of 1.94 and 2.17 mm respectively. Furthermore, we demonstrate that the robot has kinematic redundancy to reach the same target through different paths. This was evaluated in both free space and MRI-guided gelatin phantom trails, with RMS errors of 0.48 and 0.59 mm respectively. As the first of its kind, MRI-guided targeted concentric tube needle placements with ex vivo porcine liver are demonstrated with 4.64 mm RMS error through closed-loop control of the piezoelectrically-actuated robot.Keywords
Funding Information
- National Science Foundation (IIS-1054331)
- National Institutes of Health (R01CA111288)
This publication has 33 references indexed in Scilit:
- From Passive Tool Holders to Microsurgeons: Safer, Smaller, Smarter Surgical RobotsIEEE Transactions on Biomedical Engineering, 2014
- Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRIThe International Journal of Robotics Research, 2013
- Feasibility of a Pneumatically Actuated MR-compatible Robot for Transrectal Prostate Biopsy GuidanceRadiology, 2011
- Equilibrium Conformations of Concentric-tube Continuum RobotsThe International Journal of Robotics Research, 2010
- AN IMAGE-GUIDED MAGNETIC RESONANCE-COMPATIBLE SURGICAL ROBOTNeurosurgery, 2008
- Magnetic Resonance–Compatible Robotic and Mechatronics Systems for Image-Guided Interventions and Rehabilitation: A Review StudyAnnual Review of Biomedical Engineering, 2007
- Nonholonomic Modeling of Needle SteeringThe International Journal of Robotics Research, 2006
- Hand-Held Steerable Needle DeviceIEEE/ASME Transactions on Mechatronics, 2005
- Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy:In vivoevaluation using magnetic resonance thermometryMedical Physics, 2004