Multicentre clinical simulation evaluation of the ISO 80369‐6 neuraxial non‐Luer connector
Authors:
- 21 February 2019
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 74 (5) , 619-629
Abstract
Summary: To avoid potentially fatal wrong‐route neuraxial drug errors, international standard ISO 80369‐6 specifying a non‐Luer neuraxial connector design was published in 2016. We describe usability studies used in development of the design. Thirty‐eight doctors and 17 nurses performed simulated procedures on manikins, using devices fitted with Luer connectors or draft ISO 80369‐6 ‘non‐Luer’ connectors. The procedures included spinal anaesthesia; intrathecal chemotherapy; lumbar puncture, cerebrospinal fluid collection and pressure measurement; epidural catheter placement with bolus injection and critical care use. Participants attempted cross connection between neuraxial connectors and a range of other medical device connectors, including those from the ISO 80369 small‐bore connector series. Video recording analysis was used for all assessments. Participants subjectively assessed performance of the draft non‐Luer connector, including suitability for routine clinical use. Participants performed 198 procedures. The connector achieved easy, leak‐free connections. The willingness of participants to use the non‐Luer connectors were: spinal anaesthesia 100%; intrathecal chemotherapy 88%; lumbar puncture, cerebrospinal fluid collection and pressure measurement 93%; epidural catheter placement with bolus injection 78%; critical care use 100%. Concerns raised were generally device related, rather than connector related. Most cross‐connection attempts failed, even using above clinical forces and, when successful, were judged of low clinical risk potential; the exception was a malaligned connection between the non‐Luer slip and female Luer connectors. This led to revision of the dimensional tolerances of the non‐Luer connector to reduce this risk, before publication of the final specification in 2016. We conclude that the ISO 80369‐6 neuraxial non‐Luer connector is suitable for clinical use.Keywords
This publication has 11 references indexed in Scilit:
- Refractory status epilepticus after inadvertent intrathecal injection of tranexamic acid treated by magnesium sulfateInternational Journal of Obstetric Anesthesia, 2016
- An evaluation of non‐Luer safety connectors for neuraxial proceduresAnaesthesia, 2013
- Non‐Luer connectors: are we nearly there yet?Anaesthesia, 2012
- Simulated evaluation of a non-Luer safety connector system for use in neuraxial proceduresBritish Journal of Anaesthesia, 2011
- Non‐Luer neuraxial equipment and anaesthetists’ attitudes to changeAnaesthesia, 2010
- Replacing Luer connectors: still work in progressAnaesthesia, 2010
- A simulation‐based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia*Anaesthesia, 2010
- An engineered solution to the maladministration of spinal injectionsQuality and Safety in Health Care, 2009
- Major complications of central neuraxial block: report on the Third National Audit Project of the Royal College of AnaesthetistsBritish Journal of Anaesthesia, 2009
- Algorithm AS 183: An Efficient and Portable Pseudo-Random Number GeneratorJournal of the Royal Statistical Society Series C: Applied Statistics, 1982