Sample thickness and quantitative concentration measurements in BrK-edge XANES spectroscopy of organic materials
- 12 March 2014
- journal article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 21 (3) , 623-626
Abstract
While XANES spectroscopy is an established tool for quantitative information on chemical structure and speciation, elemental concentrations are generally quantified by other methods. The edge step in XANES spectra represents the absolute amount of the measured element in the sample, but matrix effects and sample thickness complicate the extraction of accurate concentrations from XANES measurements, particularly at hard X-ray energies where the X-ray beam penetrates deeply into the sample. The present study demonstrates a method of quantifying concentration with a detection limit approaching 1 mg kg−1using information routinely collected in the course of a hard X-ray XANES experiment. The XANES normalization procedure unambiguously separates the signal of the absorber from any source of background. The effects of sample thickness on edge steps at the bromineK-edge were assessed and an empirical correction factor for use with samples of variable mass developed.Keywords
This publication has 18 references indexed in Scilit:
- Quantitative Determination of Absolute Organohalogen Concentrations in Environmental Samples by X-ray Absorption SpectroscopyAnalytical Chemistry, 2006
- ATHENA,ARTEMIS,HEPHAESTUS: data analysis for X-ray absorption spectroscopy usingIFEFFITJournal of Synchrotron Radiation, 2005
- Elimination of self-absorption in fluorescence hard-x-ray absorption spectraPhysical Review B, 1999
- A novel method to ascertain sample mass thickness and matrix effects for X‐ray fluorescence element determinationsX-Ray Spectrometry, 1994
- X-ray Standing Waves and the critical sample thickness for Total-reflectionSpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- X-ray monochromator system for use with synchrotron radiation sourcesReview of Scientific Instruments, 1981
- PIXE calibration and correction of matrix effects in the case of thick samplesNuclear Instruments and Methods, 1981
- Matrix corrections for energy dispersive x-ray fluorescence analysis of environmental samples with coherent/incoherent scattered x-raysAnalytical Chemistry, 1977
- A simple method to evaluate the matrix effects in X‐Ray fluorescence analysisX-Ray Spectrometry, 1972
- CI.The efficiency of production of fluorescent X-raysJournal of Computers in Education, 1929