Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization
Open Access
- 6 May 2015
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 1-13
Abstract
Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. A NaI(Tl) gamma counter was characterized with respect to count rate performance, adequacy of detector shielding, system stability, and sample volume effects using positron-emitting radionuclides (409- to 613-keV energy window). System efficiency was measured using 18F and compared with corresponding data obtained using a long-lived 68Ge/68Ga source that was implicitly traceable to a national standard. One percent count loss was measured at 450 × 103 counts per minute. Penetration of the detector shielding by 511-keV photons gave rise to a negligible background count rate. System stability tests showed a coefficient of variation of 0.13% over 100 days. For a sample volume of 4 mL, the efficiencies relative to those at 0.1 mL were 0.96, 0.94, 0.91, 0.78, and 0.72 for 11C, 18F, 125I, 99mTc, and 51Cr, respectively. The efficiency of a traceable 68Ge/68Ga source was 30.1% ± 0.07% and was found to be in close agreement with the efficiency for 18F after consideration of the different positron fractions. Long-lived 68Ge/68Ga reference sources, implicitly traceable to a national metrology institute, can aid standardization of gamma counter calibration for 18F. A characteristic feature of positron emitters meant that accurate calibration could be maintained over a wide range of sample volumes by using a narrow energy window centered on the 511-keV peak.Keywords
This publication has 14 references indexed in Scilit:
- A new NIST primary standardization of 18FApplied Radiation and Isotopes, 2014
- In Hot BloodJACC: Cardiovascular Imaging, 2013
- 5-(5-(6-[11C]methyl-3,6-diazabicyclo[3.2.0]heptan-3-yl)pyridin-2-yl)-1H-indole as a potential PET radioligand for imaging cerebral α7-nAChR in miceBioorganic & Medicinal Chemistry, 2012
- Development of a Traceable Calibration Methodology for Solid68Ge/68Ga Sources Used as a Calibration Surrogate for18F in Radionuclide Activity CalibratorsJournal of Nuclear Medicine, 2010
- Detection efficiency calculation for photons, electrons and positrons in a well detector. Part I: Analytical modelNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Measurement of the α4β2* nicotinic acetylcholine receptor ligand 2-[18F]Fluoro-A-85380 and its metabolites in human blood during PET investigation: a methodological studyNuclear Medicine and Biology, 2007
- [ 111 In]Bz-DTPA-hEGF: Preparation and In Vitro Characterization of a Potential Anti-Glioblastoma Targeting AgentCancer Biotherapy and Radiopharmaceuticals, 2003
- Measurement of Blood Volume and Red Cell Mass: Re-examination of 51Cr and 125I MethodsBlood Cells, Molecules, and Diseases, 1996
- An improved gamma well counter for radioactive tracer applicationsThe International Journal of Applied Radiation and Isotopes, 1976
- Scintillation Counters for Radioactive Sample MeasurementReview of Scientific Instruments, 1951