Daniel P Holt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel P Holt has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dean F. Wong
Section of High Resolution Brain Positron Emission Tomography Imaging, Division of Nuclear Medicine and Molecular Imaging, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
1 shared publication - Martin A. Lodge
Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD
1 shared publication - Paul Eugene Kinahan
Department of Radiology University of Washington Seattle Washington USA
1 shared publication - Richard L. Wahl
Washington University, St Louis, MO
1 shared publication
Latest Publications
- Open Access
- 6 May 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 1-13
Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization
Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. A NaI(Tl) gamma counter was characterized with respect to count rate performance, adequacy of detector shielding, system stability, and sample volume effects using positron-emitting radionuclides (409- to 613-keV energy window). System efficiency was measured using 18F and compared with corresponding data obtained using a long-lived 68Ge/68Ga source that was implicitly traceable to a national standard. One percent count loss was measured at 450 × 103 counts per minute. Penetration of the detector shielding by 511-keV photons gave rise to a negligible background count rate. System stability tests showed a coefficient of variation of 0.13% over 100 days. For a sample volume of 4 mL, the efficiencies relative to those at 0.1 mL were 0.96, 0.94, 0.91, 0.78, and 0.72 for 11C, 18F, 125I, 99mTc, and 51Cr, respectively. The efficiency of a traceable 68Ge/68Ga source was 30.1% ± 0.07% and was found to be in close agreement with the efficiency for 18F after consideration of the different positron fractions. Long-lived 68Ge/68Ga reference sources, implicitly traceable to a national metrology institute, can aid standardization of gamma counter calibration for 18F. A characteristic feature of positron emitters meant that accurate calibration could be maintained over a wide range of sample volumes by using a narrow energy window centered on the 511-keV peak.
- 6 May 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 1-13
Open AccessPerformance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization
Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. A NaI(Tl) gamma counter was characterized with respect to count rate performance, adequacy of detector shielding, system stability, and sample volume effects using positron-emitting radionuclides (409- to 613-keV energy window). System efficiency was measured using 18F and compared with corresponding data obtained using a long-lived 68Ge/68Ga source that was implicitly traceable to a national standard. One percent count loss was measured at 450 × 103 counts per minute. Penetration of the detector shielding by 511-keV photons gave rise to a negligible background count rate. System stability tests showed a coefficient of variation of 0.13% over 100 days. For a sample volume of 4 mL, the efficiencies relative to those at 0.1 mL were 0.96, 0.94, 0.91, 0.78, and 0.72 for 11C, 18F, 125I, 99mTc, and 51Cr, respectively. The efficiency of a traceable 68Ge/68Ga source was 30.1% ± 0.07% and was found to be in close agreement with the efficiency for 18F after consideration of the different positron fractions. Long-lived 68Ge/68Ga reference sources, implicitly traceable to a national metrology institute, can aid standardization of gamma counter calibration for 18F. A characteristic feature of positron emitters meant that accurate calibration could be maintained over a wide range of sample volumes by using a narrow energy window centered on the 511-keV peak.