Improved analysis of micro‐ and nanomole‐scale sulfur multi‐isotope compositions by gas source isotope ratio mass spectrometry
- 29 February 2016
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 30 (7) , 897-907
Abstract
Rationale: Multiple sulfur isotope compositions are usually measured on relatively large samples (in the range of micromoles); however, sometimes only small amounts are available and thus it is necessary to analyze small (sub‐micromole) samples. We report an improved method to measure multiple sulfur isotope compositions: δ 33 S, δ 34 S and δ 36 S values on the SF 6 molecule ( m / z 127, 128, 129, 131) for quantities down to 0.1 micromole, and δ 33 S and δ 34 S values for quantities down to 20 nanomoles. Methods: Multiple sulfur isotope analyses including fluorination and purification of two international Ag 2 S standards, IAEA‐S1 and IAEA‐S3, were carried out at various low concentrations on a dual‐inlet isotope ratio mass spectrometer using a microvolume and modified resistor capacities. Results: The analyses yielded a narrow range of δ 34 S values vs CDT (the international standard), with an overall standard deviation of ±0.2 ‰, which was within the range of certified values. This demonstrates the feasibility of determining both Δ 33 S and Δ 36 S values on the sub‐micromole scale, and Δ 33 S values on the nanomole scale with similar accuracy to conventional dual‐inlet analyses. Conclusions: The analysis of the three S‐isotope ratios on the SF 6 molecule using the so‐called conventional fluorination method and dual‐inlet ion ratio mass spectrometry is reliable for sample sizes down to ~20 nanomoles. Despite being close to the theoretical limits for maintaining the viscous flow regime of gas in the capillary, errors were not limited by counting statistics, but probably relate to sample gas purification. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
This publication has 34 references indexed in Scilit:
- Production, preservation, and biological processing of mass-independent sulfur isotope fractionation in the Archean surface environmentProceedings of the National Academy of Sciences, 2013
- Determination of multiple sulfur isotopes in glasses: A reappraisal of the MORB δ34SChemical Geology, 2012
- Sulfur isotope fractionation during oxidation of sulfur dioxide: gas-phase oxidation by OH radicals and aqueous oxidation by H2O2, O3 and iron catalysisAtmospheric Chemistry and Physics, 2012
- Selective gas sorption in a [2+3] ‘propeller’ cage crystalChemical Communications, 2011
- Evaluating the role of microbial sulfate reduction in the early Archean using quadruple isotope systematicsEarth and Planetary Science Letters, 2009
- Mass-dependent fractionation of quadruple stable sulfur isotope system as a new tracer of sulfur biogeochemical cyclesGeochimica et Cosmochimica Acta, 2006
- Aerosol sulphate and its oxidation on the Pacific NW coast: S and O isotopes in PM2.5Atmospheric Environment, 2006
- Simultaneous determination of δ 33 S V‐CDT and δ 34 S V‐CDT using masses 48, 49 and 50 on a continuous flow isotope ratio mass spectrometerRapid Communications in Mass Spectrometry, 2004
- Multiple sulfur isotopes and the evolution of the atmosphereEarth and Planetary Science Letters, 2003
- Isotopic evidence for the origin of sulphate in coastal rainTellus B: Chemical and Physical Meteorology, 1996